Literature DB >> 1894657

Measurement of lower limb alignment using long radiographs.

J G Wright1, N Treble, A R Feinstein.   

Abstract

Long radiographs are used to measure lower limb axial alignment, to assess the progression of deformity, and to plan corrective surgery. The purpose of this study was to test the belief that jigs are necessary in order to control limb position for radiography. Above-knee amputated limbs were fixed in different positions of rotation and of knee flexion and radiographed to study the effect on the apparent alignment of the limb. If the limb was rotated no more than 10 degrees from the neutral the effect on apparent axial alignment was minimal and radiographic measurement was reliable. This suggests that standardised positioning jigs are not needed in routine clinical practice.

Entities:  

Mesh:

Year:  1991        PMID: 1894657

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  17 in total

1.  Length and angle measurements of the lower extremity in digital composite overview images.

Authors:  M Boewer; H Arndt; P A W Ostermann; J Petersein; S Mutze
Journal:  Eur Radiol       Date:  2004-05-26       Impact factor: 5.315

2.  The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

Authors:  Hyuk-Soo Han; Seung-Baik Kang; Chris H Jo; Sun-Hong Kim; Jung-Ha Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-08       Impact factor: 4.342

3.  Upright MRI measurement of mechanical axis and frontal plane alignment as a new technique: a comparative study with weight bearing full length radiographs.

Authors:  Emmanouil Liodakis; Mohamed Kenawey; Iosifina Doxastaki; Christian Krettek; Carl Haasper; Stefan Hankemeier
Journal:  Skeletal Radiol       Date:  2010-12-18       Impact factor: 2.199

4.  Agreement between radiological and computer navigation measurement of lower limb alignment.

Authors:  Julian Dexel; Stephan Kirschner; Klaus-Peter Günther; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-06       Impact factor: 4.342

5.  Radiographic and navigation measurements of TKA limb alignment do not correlate.

Authors:  Mark A Yaffe; Samuel S Koo; S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2008-11       Impact factor: 4.176

6.  Knee moments after unicompartmental knee arthroplasty during stair ascent.

Authors:  Yang-Chieh Fu; Kathy J Simpson; Cathleen Brown; Tracy L Kinsey; Ormonde M Mahoney
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

7.  Varus gonarthrosis predisposes to varus malalignment in TKA.

Authors:  Thomas J Heyse; Ralf Decking; Jack Davis; Friedrich Boettner; Richard S Laskin
Journal:  HSS J       Date:  2009-05-20

8.  Reliability of radiographic measurement of fracture angulation in children with femoral shaft fractures.

Authors:  Janice L Owen; Derek Stephens; James G Wright
Journal:  Can J Surg       Date:  2007-04       Impact factor: 2.089

9.  3D-2D Image Registration in Virtual Long-Film Imaging: Application to Spinal Deformity Correction.

Authors:  A Uneri; X Zhang; J W Stayman; P A Helm; G M Osgood; N Theodore; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-08

10.  An MRI-based technique for assessment of lower extremity deformities-reproducibility, accuracy, and clinical application.

Authors:  Stefan Hinterwimmer; Heiko Graichen; Thomas J Vogl; Nasreddin Abolmaali
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 7.034