Literature DB >> 2016608

The accuracy of tibial intramedullary alignment devices in total knee arthroplasty.

E D Simmons1, J A Sullivan, S Rackemann, R D Scott.   

Abstract

The accuracy of a tibial medullary alignment device is assessed radiographically in 30 varus and 30 valgus knees undergoing total knee arthroplasty. The results suggest that although the device is reliable and accurate for varus knees, it may lead to malalignment of up to 5 degrees in valgus knees. Overall neutral alignment was achieved in 83% of the varus knees and 37% of the valgus knees. Tibial bowing was the main source of error and was present in 66% of the valgus knees, with mean of 3 degrees. Preoperative long films or cross-checking with external alignment devices is recommended to assure neutral alignment in genu valgus deformity.

Entities:  

Mesh:

Year:  1991        PMID: 2016608     DOI: 10.1016/s0883-5403(06)80156-7

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

Authors:  Hyuk-Soo Han; Seung-Baik Kang; Chris H Jo; Sun-Hong Kim; Jung-Ha Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-08       Impact factor: 4.342

2.  The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Fink; Sebastian Quirbach; Rene Attal; Katja Tecklenburg; Christian Hoser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-20       Impact factor: 4.342

3.  Reliable and reproducible technique to mark center of ankle in total knee arthroplasty.

Authors:  Anshul Sobti; Shriji Maniar; Sameer Chaudhari; Vivek Shetty
Journal:  J Clin Orthop Trauma       Date:  2015-03-19

4.  Accuracy of a proximal tibial cutting method using the anterior tibial border in TKA.

Authors:  Hideyuki Sasanuma; Hitoshi Sekiya; Kenzo Takatoku; Takashi Ajiki; Hiroyoshi Hagiwara
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-22

5.  Analysis of the effect of tibial torsion on tibial osteotomy in knee arthroplasty using a three-dimensional computed tomography-based modelling technique.

Authors:  Yeran Li; Yu-Hang Gao; Jianguo Liu; Chen Yang; Ming Li; Xin Qi
Journal:  BMC Musculoskelet Disord       Date:  2019-08-07       Impact factor: 2.362

6.  Lateralization of Tibial Plateau Reference Point Improves Accuracy of Tibial Resection in Total Knee Arthroplasty in Patients with Proximal Tibia Vara.

Authors:  Rajshekhar K Thippana; Malhar N Kumar
Journal:  Clin Orthop Surg       Date:  2017-11-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.