Literature DB >> 20447756

Temperature dependent behavior of ultrasound contrast agents.

Helen Mulvana1, Eleanor Stride, Jo V Hajnal, Robert J Eckersley.   

Abstract

Recent interest in ultrasound contrast agents (UCAs) as tools for quantitative imaging and therapy has increased the need for accurate characterization. Laboratory investigations are frequently undertaken in a water bath at room temperature; however, implications for in vivo applications are not presented. Acoustic investigation of a bulk suspension of SonoVue (Bracco Research, Geneva, Switzerland) was made in a water bath at temperatures of 20-45 degrees C. UCA characteristics were significantly affected by temperature, particularly between 20 and 40 degrees C, leading to an increase in attenuation from 1.7-2.5 dB, respectively (p = 0.002) and a 2-dB increase in scattered signal over the same range (p = 0.05) at an insonation pressure of 100 kPa. Optical data supported the hypothesis that a temperature-mediated increase in diameter was the dominant cause, and revealed a decrease in bubble stability. In conclusion, measurements made at room temperature require careful interpretation with regard to behavior in vivo. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20447756     DOI: 10.1016/j.ultrasmedbio.2010.03.003

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  15 in total

1.  Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging.

Authors:  Himanshu Shekhar; Joshua J Rychak; Marvin M Doyley
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 2.  Contrast-enhanced voiding urosonography, part 1: vesicoureteral reflux evaluation.

Authors:  Aikaterini Ntoulia; Elisa Aguirre Pascual; Susan J Back; Richard D Bellah; Viviana P Beltrán Salazar; Pui Kwan Joyce Chan; Jeanne S Chow; David Coca Robinot; Kassa Darge; Carmina Duran; Monica Epelman; Damjana Ključevšek; Jeannie K Kwon; Preet Kiran Sandhu; Magdalena M Woźniak; Frederica Papadopoulou
Journal:  Pediatr Radiol       Date:  2021-03-31

3.  Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability.

Authors:  M-X Tang; H Mulvana; T Gauthier; A K P Lim; D O Cosgrove; R J Eckersley; E Stride
Journal:  Interface Focus       Date:  2011-05-18       Impact factor: 3.906

4.  Effect of Temperature on the Size Distribution, Shell Properties, and Stability of Definity®.

Authors:  Himanshu Shekhar; Nathaniel J Smith; Jason L Raymond; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2017-11-22       Impact factor: 2.998

5.  Photoacoustic technique to measure temperature effects on microbubble viscoelastic properties.

Authors:  Jordan S Lum; David M Stobbe; Mark A Borden; Todd W Murray
Journal:  Appl Phys Lett       Date:  2018-03-14       Impact factor: 3.791

6.  Stability of echogenic liposomes as a blood pool ultrasound contrast agent in a physiologic flow phantom.

Authors:  Kirthi Radhakrishnan; Kevin J Haworth; Shao-Ling Huang; Melvin E Klegerman; David D McPherson; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2012-08-25       Impact factor: 2.998

7.  Broadband attenuation measurements of phospholipid-shelled ultrasound contrast agents.

Authors:  Jason L Raymond; Kevin J Haworth; Kenneth B Bader; Kirthi Radhakrishnan; Joseph K Griffin; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2013-11-19       Impact factor: 2.998

8.  Evaluation of methods for sizing and counting of ultrasound contrast agents.

Authors:  Charles A Sennoga; James S M Yeh; Julia Alter; Eleanor Stride; Petros Nihoyannopoulos; John M Seddon; Dorian O Haskard; Joseph V Hajnal; Meng-Xing Tang; Robert J Eckersley
Journal:  Ultrasound Med Biol       Date:  2012-03-06       Impact factor: 2.998

9.  Optimal Control of SonoVue Microbubbles to Estimate Hydrostatic Pressure.

Authors:  Amanda Q X Nio; Alessandro Faraci; Kirsten Christensen-Jeffries; Jason L Raymond; Mark J Monaghan; Daniel Fuster; Flemming Forsberg; Robert J Eckersley; Pablo Lamata
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-21       Impact factor: 2.725

10.  Volume quantification by contrast-enhanced ultrasound: an in-vitro comparison with true volumes and thermodilution.

Authors:  Ingeborg H F Herold; Gianna Russo; Massimo Mischi; Patrick Houthuizen; Tamerlan Saidov; Marcel van het Veer; Hans C van Assen; Hendrikus H M Korsten
Journal:  Cardiovasc Ultrasound       Date:  2013-10-17       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.