Literature DB >> 20447264

Accuracy assessment of computer-assisted flapless implant placement in partial edentulism.

N Van Assche1, D van Steenberghe, M Quirynen, R Jacobs.   

Abstract

AIM: To assess the accuracy of implants placed flapless by a stereolithographic template in partially edentulous patients.
MATERIAL AND METHODS: Eight patients, requiring two to four implants (maxilla or mandible), were consecutively recruited. Radiographical data were obtained by means of a cone beam or a multi-slice CT scan and imported in a software program. Implants (n=21) were planned in a virtual environment, leading to the manufacture of one stereolithographic template per patient to guide the implant placement in a one-stage flapless procedure. A postoperative cone beam CT was performed to calculate the difference between virtual implant (n=21) positions in the preoperative planning and postoperative situation.
RESULTS: A mean angular deviation of 2.7 degrees (range 0.4-8, SD 1.9), with a mean deviation at the apex of 1.0 mm (range 0.2-3.0, SD 0.7), was observed. If one patient, a dropout because of non-conformity with the protocol, was excluded, the angular deviation was reduced to 2.2 degrees (range 0.6-3.9, SD 1.1), and the apical deviation to 0.9 mm (range 0.2-1.8).
CONCLUSION: Based on this limited patient population, a flapless implant installation appears to be a useful procedure even when based on accurate and reliable 3D CT-based image data and a dedicated implant planning software.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20447264     DOI: 10.1111/j.1600-051X.2010.01535.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  18 in total

1.  The influence of exposure parameters on jawbone model accuracy using cone beam CT and multislice CT.

Authors:  B Vandenberghe; S Luchsinger; J Hostens; E Dhoore; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Automated implant segmentation in cone-beam CT using edge detection and particle counting.

Authors:  Ruben Pauwels; Reinhilde Jacobs; Hilde Bosmans; Pisha Pittayapat; Pasupen Kosalagood; Onanong Silkosessak; Soontra Panmekiate
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

3.  A novel workflow for computer guided implant surgery matching digital dental casts and CBCT scan.

Authors:  G DE Vico; F Ferraris; L Arcuri; F Guzzo; D Spinelli
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

4.  Implant Bed Preparation with an Erbium, Chromium Doped Yttrium Scandium Gallium Garnet (Er,Cr: YSGG) Laser Using Stereolithographic Surgical Guide.

Authors:  Gülin Seymen; Zeynep Turgut; Gizem Berk; Ayşen Bodur
Journal:  J Lasers Med Sci       Date:  2013

Review 5.  Use of cone beam computed tomography in periodontology.

Authors:  Buket Acar; Kıvanç Kamburoğlu
Journal:  World J Radiol       Date:  2014-05-28

Review 6.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

7.  3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Jens Dreyhaupt; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-01-22       Impact factor: 3.573

8.  Computer guided implantology accuracy and complications.

Authors:  Vincenzo Bruno; Mauro Badino; Francesco Riccitiello; Gianrico Spagnuolo; Massimo Amato
Journal:  Case Rep Dent       Date:  2013-09-03

9.  Computer-designed selective laser sintering surgical guide and immediate loading dental implants with definitive prosthesis in edentulous patient: A preliminary method.

Authors:  Giovanni Di Giacomo; Jorge Silva; Rodrigo Martines; Sergio Ajzen
Journal:  Eur J Dent       Date:  2014-01

10.  Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study.

Authors:  Mario Beretta; Pier Paolo Poli; Carlo Maiorana
Journal:  J Periodontal Implant Sci       Date:  2014-08-28       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.