Literature DB >> 20426076

Bias of least squares approaches for diffusion tensor estimation from array coils in DT-MRI.

Antonio Tristán-Vega1, Carl-Fredrik Westin, Santiago Aja-Fernández.   

Abstract

Least Squares (LS) and its weighted version are standard techniques to estimate the Diffusion Tensor (DT) from Diffusion Weighted Images (DWI). They require to linearize the problem by computing the logarithm of the DWI. For the single-coil Rician noise model it has been shown that this model does not introduce a significant bias, but for multiple array coils and parallel imaging, the noise cannot longer be modeled as Rician. As a result the validity of LS approaches is not assured. An analytical study of noise statistics for a multiple coil system is carried out, together with the Weighted LS formulation and noise analysis for this model. Results show that the bias in the computation of the components of the DT may be comparable to their variance in many cases, stressing the importance of unbiased filtering previous to DT estimation.

Entities:  

Mesh:

Year:  2009        PMID: 20426076      PMCID: PMC4026217          DOI: 10.1007/978-3-642-04268-3_113

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  10 in total

1.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

2.  Rician noise removal in diffusion tensor MRI.

Authors:  Saurav Basu; Thomas Fletcher; Ross Whitaker
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

3.  Clinical DT-MRI estimation, smoothing, and fiber tracking with log-Euclidean metrics.

Authors:  Pierre Fillard; Xavier Pennec; Vincent Arsigny; Nicholas Ayache
Journal:  IEEE Trans Med Imaging       Date:  2007-11       Impact factor: 10.048

4.  Signal LMMSE estimation from multiple samples in MRI and DT-MRI.

Authors:  S Aja-Fernández; C Alberola-López; C F Westin
Journal:  Med Image Comput Comput Assist Interv       Date:  2007

5.  Impact of an improved combination of signals from array coils in diffusion tensor imaging.

Authors:  Guillaume Gilbert; Dany Simard; Gilles Beaudoin
Journal:  IEEE Trans Med Imaging       Date:  2007-11       Impact factor: 10.048

6.  Impact of Rician adapted Non-Local Means filtering on HARDI.

Authors:  Maxime Descoteaux; Nicolas Wiest-Daesslé; Sylvain Prima; Christian Barillot; Rachid Deriche
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

7.  Rician noise removal by non-Local Means filtering for low signal-to-noise ratio MRI: applications to DT-MRI.

Authors:  Nicolas Wiest-Daesslé; Sylvain Prima; Pierrick Coupé; Sean Patrick Morrissey; Christian Barillot
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

8.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

9.  The Rician distribution of noisy MRI data.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

10.  Formal characterization and extension of the linearized diffusion tensor model.

Authors:  Raymond Salvador; Alonso Peña; David K Menon; T Adrian Carpenter; John D Pickard; Ed T Bullmore
Journal:  Hum Brain Mapp       Date:  2005-02       Impact factor: 5.038

  10 in total
  4 in total

1.  Optimal real-time estimation in diffusion tensor imaging.

Authors:  Pablo Casaseca-de-la-Higuera; Antonio Tristán-Vega; Santiago Aja-Fernández; Carlos Alberola-López; Carl-Fredrik Westin; Raúl San José Estépar
Journal:  Magn Reson Imaging       Date:  2012-02-02       Impact factor: 2.546

2.  Least squares for diffusion tensor estimation revisited: propagation of uncertainty with Rician and non-Rician signals.

Authors:  Antonio Tristán-Vega; Santiago Aja-Fernández; Carl-Fredrik Westin
Journal:  Neuroimage       Date:  2011-10-08       Impact factor: 6.556

3.  Statistical noise analysis in GRAPPA using a parametrized noncentral Chi approximation model.

Authors:  Santiago Aja-Fernández; Antonio Tristán-Vega; W Scott Hoge
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

4.  Abnormalities in myelination of the superior cerebellar peduncle in patients with schizophrenia and deficits in movement sequencing.

Authors:  Jitka Hüttlova; Zora Kikinis; Milos Kerkovsky; Sylvain Bouix; Mai-Anh Vu; Nikos Makris; Martha Shenton; Tomas Kasparek
Journal:  Cerebellum       Date:  2014-08       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.