Literature DB >> 20425494

Understanding the C-pulse device and its potential to treat heart failure.

Virna L Sales1, Patrick M McCarthy.   

Abstract

The Sunshine Heart C-Pulse (C-Pulse; Sunshine Heart Inc., Tustin, CA) device is an extra-aortic implantable counterpulsation pump designed as a non-blood contacting ambulatory heart assist device, which may provide relief from symptoms for class II-III congestive heart failure patients. It has a comparable hemodynamic augmentation to intra-aortic balloon counterpulsation devices. The C-Pulse cuff is implanted through a median sternotomy, secured around the ascending aorta, and pneumatically driven by an external system controller. Pre-clinical studies in the acute pig model, and initial temporary clinical studies in patients undergoing off-pump coronary bypass surgery have shown substantial increase in diastolic perfusion of the coronary vessels, which translated to a favorable improvement in ventricular function. A U.S. prospective multi-center trial to evaluate the safety and efficacy of the C-Pulse in class III patients with moderate heart failure is now in progress.

Entities:  

Mesh:

Year:  2010        PMID: 20425494     DOI: 10.1007/s11897-010-0007-7

Source DB:  PubMed          Journal:  Curr Heart Fail Rep        ISSN: 1546-9530


  11 in total

1.  Long-term use of a left ventricular assist device for end-stage heart failure.

Authors:  E A Rose; A C Gelijns; A J Moskowitz; D F Heitjan; L W Stevenson; W Dembitsky; J W Long; D D Ascheim; A R Tierney; R G Levitan; J T Watson; P Meier; N S Ronan; P A Shapiro; R M Lazar; L W Miller; L Gupta; O H Frazier; P Desvigne-Nickens; M C Oz; V L Poirier
Journal:  N Engl J Med       Date:  2001-11-15       Impact factor: 91.245

2.  Cardiac resynchronization in chronic heart failure.

Authors:  William T Abraham; Westby G Fisher; Andrew L Smith; David B Delurgio; Angel R Leon; Evan Loh; Dusan Z Kocovic; Milton Packer; Alfredo L Clavell; David L Hayes; Myrvin Ellestad; Robin J Trupp; Jackie Underwood; Faith Pickering; Cindy Truex; Peggy McAtee; John Messenger
Journal:  N Engl J Med       Date:  2002-06-13       Impact factor: 91.245

3.  Origins of intraaortic balloon pumping.

Authors:  A Kantrowitz
Journal:  Ann Thorac Surg       Date:  1990-10       Impact factor: 4.330

4.  Beat-to-beat augmentation of left ventricular function by intraaortic counterpulsation.

Authors:  A T Cheung; J S Savino; S J Weiss
Journal:  Anesthesiology       Date:  1996-03       Impact factor: 7.892

5.  Relation of hemodynamic variables to augmentation of left anterior descending coronary flow by intraaortic balloon pulsation in coronary artery disease.

Authors:  M Zehetgruber; G Mundigler; G Christ; C Merhaut; U Klaar; C Kratochwill; T Neunteufl; S Hofmann; G Heinz; G Maurer; P Siostrzonek
Journal:  Am J Cardiol       Date:  1997-10-01       Impact factor: 2.778

6.  Initial clinical experience with intraaortic balloon pumping in cardiogenic shock.

Authors:  A Kantrowitz; S Tjonneland; P S Freed; S J Phillips; A N Butner; J L Sherman
Journal:  JAMA       Date:  1968-01-08       Impact factor: 56.272

7.  Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay.

Authors:  S Cazeau; C Leclercq; T Lavergne; S Walker; C Varma; C Linde; S Garrigue; L Kappenberger; G A Haywood; M Santini; C Bailleul; J C Daubert
Journal:  N Engl J Med       Date:  2001-03-22       Impact factor: 91.245

8.  Extra-ascending aortic versus intra-descending aortic balloon counterpulsation-effect on coronary artery blood flow.

Authors:  Andrew N Davies; William S Peters; Tonglin Su; Colin E Sullivan; Theo Perkidides; F Paget Milsom; Geoffrey White
Journal:  Heart Lung Circ       Date:  2005-07-25       Impact factor: 2.975

9.  Incidence and patterns of adverse event onset during the first 60 days after ventricular assist device implantation.

Authors:  Elizabeth A Genovese; Mary Amanda Dew; Jeffrey J Teuteberg; Marc A Simon; Joy Kay; Michael P Siegenthaler; Jay K Bhama; Christian A Bermudez; Kathleen L Lockard; Steve Winowich; Robert L Kormos
Journal:  Ann Thorac Surg       Date:  2009-10       Impact factor: 4.330

10.  Implantable LVAD infections: implications for permanent use of the device.

Authors:  P M McCarthy; S K Schmitt; R L Vargo; S Gordon; T F Keys; R E Hobbs
Journal:  Ann Thorac Surg       Date:  1996-01       Impact factor: 4.330

View more
  6 in total

1.  The future of adult cardiac assist devices: novel systems and mechanical circulatory support strategies.

Authors:  Carlo R Bartoli; Robert D Dowling
Journal:  Cardiol Clin       Date:  2011-11       Impact factor: 2.213

2.  Concept and first experimental results of a new ferromagnetic assist device for extra-aortic counterpulsation.

Authors:  Christoph T Starck; Jakob Becker; Roland Fuhrer; Simon Sündermann; Jan Wendelin Stark; Volkmar Falk
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-09-22

Review 3.  Aortic counterpulsation: C-pulse and other devices for cardiac support.

Authors:  Pallavi Solanki
Journal:  J Cardiovasc Transl Res       Date:  2014-02-20       Impact factor: 4.132

4.  Muscle-Powered Counterpulsation for Untethered, Non-Blood-Contacting Cardiac Support: A Path to Destination Therapy.

Authors:  Jooli Han; Edgar Aranda-Michel; Dennis R Trumble
Journal:  IEEE Trans Biomed Eng       Date:  2020-02-18       Impact factor: 4.538

5.  New developments in the surgical management of end-stage heart failure.

Authors:  Scott Silvestry
Journal:  Mo Med       Date:  2012 Jul-Aug

6.  Preliminary Results From the C-Pulse OPTIONS HF European Multicenter Post-Market Study.

Authors:  Antonia Schulz; Thomas Krabatsch; Jan D Schmitto; Roland Hetzer; Mirko Seidel; Pascal M Dohmen; Holger Hotz
Journal:  Med Sci Monit Basic Res       Date:  2016-02-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.