Literature DB >> 2222066

Origins of intraaortic balloon pumping.

A Kantrowitz1.   

Abstract

In 1968, the Journal of the American Medical Association published a paper on the "Initial clinical experience with intraaortic balloon pumping in cardiogenic shock," which gave the results of the first clinical use of the procedure developed in our laboratory. For more than 2 years, our group was the only one using intraaortic balloon pumping clinically. Later, intraaortic balloon pumping was used by others, and despite poor clinical salvage, the hemodynamic benefit was demonstrated convincingly. At the present time, approximately 70,000 balloon pump procedures are performed annually.

Entities:  

Mesh:

Year:  1990        PMID: 2222066     DOI: 10.1016/0003-4975(90)90220-z

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  11 in total

1.  The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome.

Authors:  Haralabos Parissis; Michael Leotsinidis; Mohammad Tauqeer Akbar; Efstratios Apostolakis; Dimitrios Dougenis
Journal:  J Cardiothorac Surg       Date:  2010-04-05       Impact factor: 1.637

Review 2.  Understanding the C-pulse device and its potential to treat heart failure.

Authors:  Virna L Sales; Patrick M McCarthy
Journal:  Curr Heart Fail Rep       Date:  2010-03

3.  Muscle-Powered Counterpulsation for Untethered, Non-Blood-Contacting Cardiac Support: A Path to Destination Therapy.

Authors:  Jooli Han; Edgar Aranda-Michel; Dennis R Trumble
Journal:  IEEE Trans Biomed Eng       Date:  2020-02-18       Impact factor: 4.538

4.  A statistical model that predicts the length from the left subclavian artery to the celiac axis; towards accurate intra aortic balloon sizing.

Authors:  Haralabos Parissis; Alan Soo; Michalis Leotsinidis; Dimitrios Dougenis
Journal:  J Cardiothorac Surg       Date:  2011-08-09       Impact factor: 1.637

Review 5.  Clinical review: mechanical circulatory support for cardiogenic shock complicating acute myocardial infarction.

Authors:  Matthew E Cove; Graeme MacLaren
Journal:  Crit Care       Date:  2010-10-14       Impact factor: 9.097

Review 6.  Mechanical circulatory support in acute cardiogenic shock.

Authors:  Mubashar H Khan; Brian J Corbett; Steven M Hollenberg
Journal:  F1000Prime Rep       Date:  2014-10-01

Review 7.  IABP: history-evolution-pathophysiology-indications: what we need to know.

Authors:  H Parissis; V Graham; S Lampridis; M Lau; G Hooks; P C Mhandu
Journal:  J Cardiothorac Surg       Date:  2016-08-04       Impact factor: 1.637

8.  Ultrasound-guided insertion of intra-aortic balloon counterpulsation in intensive care: description of the technique.

Authors:  David Rene Rodriguez Lima; Ever Julián Duran; Ever Leonardo Rojas Díaz; Darío Isaías Pinilla Rojas; Mario Andrés Mercado Díaz; Yury Forlán Bustos Martínez
Journal:  Ultrasound J       Date:  2020-04-21

9.  Perioperative incidence of ECMO and IABP on 5901 mitral valve surgery procedures.

Authors:  Ignazio Condello; Roberto Lorusso; Giuseppe Santarpino; Nicola Di Bari; Flavio Fiore; Marco Moscarelli; Antonio Maria Calafiore; Giuseppe Speziale; Giuseppe Nasso
Journal:  J Cardiothorac Surg       Date:  2022-03-17       Impact factor: 1.637

10.  Postoperative Cardiac Arrest in Cardiac Surgery-How to Improve the Outcome?

Authors:  Ashraf Fadel Moh'd; Mohammad Abdallah Khasawneh; Hayel Talal Al-Odwan; Yaser Ahmad Alghoul; Zeid Mohammad Makahleh; Salah E Altarabsheh
Journal:  Med Arch       Date:  2021-04
View more