Literature DB >> 20418732

The 'safe zone' for extra-articular screw placement during intra-pelvic acetabular surgery.

Pierre Guy1, Mohammad Al-Otaibi, Edward J Harvey, Nader Helmy.   

Abstract

OBJECTIVES: Intra-articular screw placement during acetabular surgery must be avoided. To date, no anatomic guidelines exist to prevent intra-articular screw placement in the treatment of complex acetabular fractures by the ilioinguinal or Stoppa approach.
METHODS: Ninety-three pelvic computed tomography scans were analyzed and the femoral head diameter (FHD) and the intersacroiliac joint distance (ISIJD) were referenced as anthropometric parameters. A safe zone for screw placement avoiding the acetabulum for specific anatomic landmarks such as the ischial spine, sciatic notch, and obturator canal was defined and correlated to the FHD and ISIJD.
RESULTS: The mean FHD was 45.5 mm (standard deviation, 3.96). The mean ISIJD was 117.9 mm (standard deviation, 6.32). The correlation for the distance of the ischial spine in relation to the femoral head diameter was 0.59 (P = 0.0101) and for the ISIJD 0.274 (P = 0.0501). A safe zone of 28 mm from the ischial spine aiming laterally for a FHD greater than 47 mm and 23 mm for a FHD less than 47 mm could be identified. The safe zone for potential screw placement near the sciatic notch was 11 mm (correlation FHD 0.234, P = 0.0501; ISIJD 0.412, P = 0.0101). A safe zone of 5 mm in relative distance of the obturator canal could be determined for screws on the pubic ramus.
CONCLUSIONS: This study identifies a safe zone for screw placement in the treatment of acetabular fractures when operated by an anterior approach. These findings have the potential to prevent further injury to the acetabular and femoral cartilage as a result of the surgical trauma and minimize intraoperative irradiation time.

Entities:  

Mesh:

Year:  2010        PMID: 20418732     DOI: 10.1097/BOT.0b013e3181bfcebf

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  18 in total

1.  Gun barrel view of the anterior pelvic ring for percutaneous anterior column or superior pubic ramus screw placement.

Authors:  Nicholas Quercetti; Brandon Horne; Zac DiPaolo; Michael J Prayson
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-10-07

2.  Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric study.

Authors:  Thomas Dienstknecht; Michael Müller; Richard Sellei; Michael Nerlich; Franz Josef Müller; Bernd Fuechtmeier; Arne Berner
Journal:  Int Orthop       Date:  2012-12-19       Impact factor: 3.075

3.  Sex-specific differences of the infraacetabular corridor: a biomorphometric CT-based analysis on a database of 523 pelves.

Authors:  Florian Gras; Heiko Gottschling; Manuel Schröder; Ivan Marintschev; Nils Reimers; Rainer Burgkart
Journal:  Clin Orthop Relat Res       Date:  2014-09-27       Impact factor: 4.176

4.  Preclinical usability study of multiple augmented reality concepts for K-wire placement.

Authors:  Marius Fischer; Bernhard Fuerst; Sing Chun Lee; Javad Fotouhi; Severine Habert; Simon Weidert; Ekkehard Euler; Greg Osgood; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-19       Impact factor: 2.924

5.  Computational simulation study on ilio-sacral screw fixations for pelvic ring injuries and implications in Asian sacrum.

Authors:  Chang-Soo Chon; Jin-Hoon Jeong; Bokku Kang; Han Sung Kim; Gu-Hee Jung
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-13

6.  The Stoppa approach for acetabular fracture.

Authors:  A Khoury; Y Weill; R Mosheiff
Journal:  Oper Orthop Traumatol       Date:  2012-09       Impact factor: 1.154

Review 7.  [3D augmented reality visualization for navigated osteosynthesis of pelvic fractures].

Authors:  N Befrui; M Fischer; B Fuerst; S-C Lee; J Fotouhi; S Weidert; A Johnson; E Euler; G Osgood; N Navab; W Böcker
Journal:  Unfallchirurg       Date:  2018-04       Impact factor: 1.000

8.  Measurement of the "safe zone" and the "dangerous zone" for the screw placement on the quadrilateral surface in the treatment of pelvic and acetabular fractures with Stoppa approach by computational 3D technology.

Authors:  Sheng Zhang; Wanhan Su; Qiang Luo; Frankie Leung; Bin Chen
Journal:  Biomed Res Int       Date:  2014-01-29       Impact factor: 3.411

9.  Digital anatomical measurements of safe screw placement at superior border of the arcuate line for acetabular fractures.

Authors:  Xiaoxi Ji; Chun Bi; Fang Wang; Yuchen Jiang; Dongmei Wang; Qiugen Wang
Journal:  BMC Musculoskelet Disord       Date:  2015-03-15       Impact factor: 2.362

10.  Secure Screw Placement in Management of Acetabular Fractures Using the Suprapectineal Quadrilateral Buttress Plate.

Authors:  R J Egli; M J B Keel; J L Cullmann; J D Bastian
Journal:  Biomed Res Int       Date:  2017-06-15       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.