OBJECTIVE: This study aims to compare the radiopacities of computer-aided design/computer-aided manufacture (CAD/CAM) blocks and the adhesive cements used for their bonding.
MATERIALS AND METHODS: 1 ± 0.2 mm thick specimens were obtained from six different CAD/CAM blocks (Incoris TZI, IPS e.max CAD, Vita Mark II, Cerasmart, Vita Enamic, and Vita Suprinity), four different adhesive resin cements (Panavia F2.0, Variolink Esthetic DC, RelyX Unicem Aplicap, G-CEM LinkAce), and a tooth. Radiographs of the specimens from each group, a tooth section, and an aluminum (Al) step-wedge were acquired. The radiopacity values of the materials were calculated as equivalents of Al thickness using the gray level values. The data were statistically analyzed using one-way ANOVA and Tukey HSD tests.
RESULTS: All the materials except Cerasmart and Vita Enamic had significantly higher radiopacity values than dentin (p < 0.05). Of the assessed blocks, the highest radiopacity value was observed in Incoris TZI, and the lowest radiopacity value was observed in Vita Enamic. Variolink Esthetic DC and RelyX Unicem Aplicap showed significantly higher radiopacity (p < 0.05) than the other adhesive cements, including enamel and dentin.
CONCLUSIONS: In this study, the majority of the CAD/CAM materials and all the adhesive resin cements were found to have sufficient radiopacity for prosthetic restorations according to the criteria set by the International Organization for Standardization (ISO). CLINICAL RELEVANCE: From a clinical and biological point of view, materials should be chosen according to their radiopacity and other properties, such as biocompatibility and esthetics. If the selected restorative CAD/CAM blocks have a radiopacity value less than or equal to dentin, cements with higher radiopacity values are recommended to facilitate radiological diagnoses for periphery and interface of restorations.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Adhesive resin cements; CAD/CAM; Radiopacity; Restorative materials

Mesh:

Substances:

Year:  2021        PMID: 33704572     DOI: 10.1007/s00784-021-03875-y

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.606


  48 in total

1.  Physical properties of resinous cements: an in vitro study.

Authors:  R C Fraga; L R Luca-Fraga; L A Pimenta
Journal:  J Oral Rehabil       Date:  2000-12       Impact factor: 3.837

2.  Radiopacity of composite dental materials using a digital X-ray system.

Authors:  Walter Dukic; Barbara Delija; Doria Derossi; Ivana Dadic
Journal:  Dent Mater J       Date:  2012-01-21       Impact factor: 2.102

3.  In vitro analysis of the radiodensity of indirect composites and ceramic inlay systems and its influence on the detection of cement overhangs.

Authors:  Carlos José Soares; Fernanda Ribeiro Santana; Rodrigo Borges Fonseca; Luis Roberto Marcondes Martins; Francisco Haiter Neto
Journal:  Clin Oral Investig       Date:  2007-06-28       Impact factor: 3.573

4.  Evaluation of Radiopacity of Luting Cements Submitted to Different Aging Procedures.

Authors:  Rafael B Junqueira; Rodrigo F Carvalho; Felipe A G F Yamamoto; Solange M Almeida; Francielle S Verner
Journal:  J Prosthodont       Date:  2018-10-28       Impact factor: 2.752

5.  Radiopacity of Resin Cements Using Digital Radiography.

Authors:  Sherif Hosney; Hanan K Abouelseoud; Omar El-Mowafy
Journal:  J Esthet Restor Dent       Date:  2017-04-18       Impact factor: 2.843

6.  Mechanical and physical properties of contemporary dental luting agents.

Authors:  Nuray Attar; Laura E Tam; Dorothy McComb
Journal:  J Prosthet Dent       Date:  2003-02       Impact factor: 3.426

7.  Radiodensity of base, liner and luting dental materials.

Authors:  Rodrigo Borges Fonseca; Carolina Assaf Branco; Paulo Vinícius Soares; Lourenço Correr-Sobrinho; Francisco Haiter-Neto; Alfredo Júlio Fernandes-Neto; Carlos José Soares
Journal:  Clin Oral Investig       Date:  2006-02-24       Impact factor: 3.573

8.  Effects of monomer ratios and highly radiopaque fillers on degree of conversion and shrinkage-strain of dental resin composites.

Authors:  Amel Amirouche-Korichi; Mohamed Mouzali; David C Watts
Journal:  Dent Mater       Date:  2009-08-15       Impact factor: 5.304

9.  Radiopacity of conventional, resin-modified glass ionomer, and resin-based luting materials.

Authors:  Takuma Tsuge
Journal:  J Oral Sci       Date:  2009-06       Impact factor: 1.556

10.  The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study.

Authors:  Thomas G Wilson
Journal:  J Periodontol       Date:  2009-09       Impact factor: 6.993

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.