Literature DB >> 22124579

Effect of various surface treatments on the retention properties of titanium to implant restorative cement.

Hakan Akin1, Umit Guney.   

Abstract

There are conflicting results in the literature and divergent manufacturers' recommendations concerning the retention properties of implant restorative cements, and they can provide inadequate retention of implants, especially short or single implants. The objective of this study was to investigate the effects of sandblasting and different types of laser irradiation on the interfacial bond between titanium and resin cement through shear testing. A total of 60 samples (10 mm in length and 12 mm in diameter) were cut from titanium rods. The samples were divided into four equal groups according to the surface treatment: control, sandblasted, Nd:YAG laser-irradiated, and Er:YAG laser-irradiated. After surface treatment, the implant restorative cements were applied to the titanium samples which were stored in distilled water at 37°C for 24 h. The samples were then subjected to shear bond strength testing using a universal testing machine with a crosshead speed of 1 mm/min. The data were analysed with the Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). The highest mean bond strength was observed in the control group, followed by the sandblasted group. A statistically significant difference in shear bond strength was found between the sandblasted group and both the laser-irradiated groups (p < 0.05). The Nd:YAG laser-irradiated group had a higher mean shear bond strength than the Er:YAG laser-irradiated group. The treatments applied to the titanium surface did not improve the strength of the bond to the implant restorative cement.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22124579     DOI: 10.1007/s10103-011-1026-7

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  25 in total

1.  Comparative evaluation of casting retention using the ITI solid abutment with six cements.

Authors:  Ahmed Mansour; Carlo Ercoli; Gerald Graser; Ross Tallents; Mark Moss
Journal:  Clin Oral Implants Res       Date:  2002-08       Impact factor: 5.977

2.  The effects of XeCl laser etching of Ni-Cr alloy on bond strengths to composite resin: a comparison with sandblasting procedures.

Authors:  Andrea K Murray; David C Attrill; Mark R Dickinson
Journal:  Dent Mater       Date:  2005-06       Impact factor: 5.304

3.  Cement selection for cement-retained crown technique with dental implants.

Authors:  James L Sheets; Charles Wilcox; Terry Wilwerding
Journal:  J Prosthodont       Date:  2007-10-30       Impact factor: 2.752

4.  Assessment of the tensile strength of hexagonal abutments using different cementing agents.

Authors:  Carlos Wahl; Fabiana Mantovani Gomes França; Rui Barbosa Brito; Roberta Tarkany Basting; Henrique Smanio
Journal:  Braz Oral Res       Date:  2008 Oct-Dec

5.  The effects of laser etching on shear bond strength at the titanium ceramic interface.

Authors:  Jin-Tae Kim; Sung-Am Cho
Journal:  J Prosthet Dent       Date:  2009-02       Impact factor: 3.426

6.  Bond strength of resin cements to a zirconia ceramic with different surface treatments.

Authors:  Andrea Nóbrega Cavalcanti; Richard Mark Foxton; Timothy Frederick Watson; Marcelo Tavares Oliveira; Marcelo Giannini; Giselle Maria Marchi
Journal:  Oper Dent       Date:  2009 May-Jun       Impact factor: 2.440

7.  Effect of different surface treatments on tensile bond strength of silicone-based soft denture liner.

Authors:  Hakan Akin; Faik Tugut; Burcu Mutaf; Gulsah Akin; A Kemal Ozdemir
Journal:  Lasers Med Sci       Date:  2010-08-21       Impact factor: 3.161

8.  Bond strength of resin cement to yttrium-stabilized tetragonal zirconia ceramic treated with air abrasion, silica coating, and laser irradiation.

Authors:  Musa Samil Akyil; Ismail Hakki Uzun; Funda Bayindir
Journal:  Photomed Laser Surg       Date:  2010-10-22       Impact factor: 2.796

9.  Strength of the bond between a silicone lining material and denture resin after Er:YAG laser treatments with different pulse durations and levels of energy.

Authors:  Faik Tugut; Hakan Akin; Burcu Mutaf; Gulsah Emine Akin; Ali Kemal Ozdemir
Journal:  Lasers Med Sci       Date:  2010-12-14       Impact factor: 3.161

Review 10.  Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry.

Authors:  K S Hebel; R C Gajjar
Journal:  J Prosthet Dent       Date:  1997-01       Impact factor: 3.426

View more
  3 in total

1.  The effect of ultrafast fiber laser application on the bond strength of resin cement to titanium.

Authors:  Sabit Melih Ates; Fatih Mehmet Korkmaz; Ipek Satıroglu Caglar; Zeynep Yeşil Duymus; Sedanur Turgut; Elif Arslan Bagis
Journal:  Lasers Med Sci       Date:  2017-05-02       Impact factor: 3.161

2.  Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

Authors:  Sina Safari; Fereshteh Hosseini Ghavam; Parviz Amini; Kaveh Yaghmaei
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

3.  Shear Bond Strength of Lithium Disilicate Bonded with Various Surface-Treated Titanium.

Authors:  Laongdao Amornwichitwech; Mali Palanuwech
Journal:  Int J Dent       Date:  2022-04-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.