| Literature DB >> 20416065 |
Tuomo Visuri1, Håkan Borg, Pekka Pulkkinen, Pekka Paavolainen, Eero Pukkala.
Abstract
BACKGROUND: All patients with total hip arthroplasty (THA), especially those with metal-on-metal (MM) THA, are exposed to metallic particles and ions, which may cause total or site-specific mortality. We analyzed the causes of total and site-specific mortality among a cohort of patients with MM and with metal-on-polyethylene (MP) THA after a long follow-up time.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20416065 PMCID: PMC2874765 DOI: 10.1186/1471-2474-11-78
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Number of patients (n) with metal-on-metal or metal-on-polyethylene prostheses stratified by age at operation and number of person-years at risk up to the end of 2005 by age at follow-up.
| Age (years) | Metal-on-metal prosthesis | Metal-on-polyethylene prosthesis | ||
|---|---|---|---|---|
| n | Person-years | n | Person-years | |
| 20 to 29 | 2 | 15.5 | 4 | 7.1 |
| 30 to 39 | 6 | 28.7 | 16 | 107.0 |
| 40 to 49 | 25 | 176.2 | 55 | 354.7 |
| 50 to 59 | 145 | 855.6 | 291 | 1800.0 |
| 60 to 69 | 278 | 2836.3 | 779 | 6694.5 |
| 70 to 79 | 113 | 3898.4 | 419 | 10848.2 |
| ≥ 80 | 10 | 2374.3 | 21 | 6595.5 |
| Total | 579 | 10185.1 | 1585 | 26406.9 |
Observed number of deaths (Obs) (all causes) and standardised mortality ratio (SMR) and rate ratio (RR) among patients with metal-on-metal and metal-on-polyethylene total hip prostheses for osteoarthritis by number of postoperative years.
| Follow-up time, completed years | Metal-on-metal prosthesis (n = 579) | Metal-on-polyethylene prosthesis (n = 1585) | ||||||
|---|---|---|---|---|---|---|---|---|
| 0 to 1 | 16 | 0.59 | 0.34-0.96* | 35 | 0.37 | 0.26-0.51*** | 1.61 | 0.83-2.98 |
| 2 through 9 | 122 | 0.77 | 0.64-0.91** | 342 | 0.70 | 0.63-0.78*** | 1.09 | 0.88-1.35 |
| 10 through 19 | 200 | 0.94 | 0.81-1.06 | 611 | 0.96 | 0.89-1.04 | 0.97 | 0.82-1.14 |
| 20+ | 190 | 1.20 | 1.04-1.37 * | 311 | 1.38 | 1.23-1.53*** | 0.87 | 0.72-1.05 |
| Total | 528 | 0.95 | 0.87-1.02 | 1299 | 0.90 | 0.85-0.95*** | 1.05 | 0.95-1.16 |
‡ 95% CI, 95% confidence interval
*p < 0.05, **p < 0.01, *** p < 0.001
Observed number of deaths (Obs) and standardised mortality ratio (SMR) among patients with metal-on-metal and metal-on-polyethylene total hip prostheses for osteoarthritis in the main disease groups.
| Cause of death | Metal-on-metal prosthesis (n = 579) | Metal-on-polyethylene prosthesis (n = 1585) | ||||
|---|---|---|---|---|---|---|
| Cancer | 96 | 0.97 | 0.79-1.18 | 206 | 0.76 | 0.66-0.86 *** |
| Cardiovascular | 300 | 0.96 | 0.86-1.07 | 702 | 0.90 | 0.84-0.97 ** |
| Respiratory | 33 | 0.67 | 0.46-0.93 * | 101 | 0.78 | 0.64-0.94 ** |
| Pneumonia | 28 | 0.87 | 0.58-1.25 | 79 | 0.96 | 0.76-1.20 |
| Alzheimer, dementia | 28 | 0.96 | 0.64-1.38 | 105 | 1.20 | 0.98-1.43 |
| Genitourinary | 8 | 0.90 | 0.39-1.76 | 27 | 1.32 | 0.87-1.91 |
| Digestive system | 18 | 1.08 | 0.64-1.71 | 45 | 1.07 | 0.78-1.43 |
| Diabetes | 6 | 0.80 | 0.29-1.74 | 7 | 0.42 | 0.17-0.86* |
| Accidents and violence | 14 | 0.78 | 0.42-1.30 | 38 | 0.79 | 0.56-1.07 |
| All causes | 528 | 0.95 | 0.87-1.02 | 1299 | 0.90 | 0.85-0.95 *** |
‡ 95% CI, 95% confidence interval
*p < 0.05, **p < 0.01, *** p < 0.001
Observed number of cancer deaths (Obs) and standardised mortality ratio (SMR) and rate ratio (RR) with 95% confidence intervals of patients with metal-on-metal and metal-on-polyethylene total hip prostheses stratified by number of postoperative years.
| Follow-up time, | Metal-on-metal prosthesis (n = 579) | Metal-on-polyethylene prosthesis (n = 1585) | ||||||
|---|---|---|---|---|---|---|---|---|
| 0 to 1 | 2 | 0.35 | 0.04-1.27 | 3 | 0.14 | 0.03-0.41*** | 2.51 | 0.21 -21.94 |
| 2 through 9 | 29 | 0.92 | 0.62-1.32 | 77 | 0.78 | 0.61-0.96* | 1.19 | 0.74 - 1.85 |
| 10 through 19 | 43 | 1.19 | 0.86-1.59 | 89 | 0.84 | 0.67-1.02 | 1.42 | 0.96 - 2.07 |
| 20+ | 19 | 0.84 | 0.50-1.30 | 33 | 0.89 | 0.61-1.24 | 0.95 | 0.51 - 1.71 |
| Total | 93 | 0.97 | 0.78-1.18 | 202 | 0.76 | 0.66-0.87*** | 1.27 | 0.98 - 1.63 |
‡ 95% CI, 95% confidence interval
*p < 0.05, **p < 0.01, *** p < 0.001
Observed number of cardiovascular deaths (Obs) and standardised mortality ratio (SMR) and rate ratio (RR) with 95% confidence intervals of patients with metal-on-metal and metal-on-polyethylene total hip prostheses stratified by number of postoperative years.
| Follow-up time, | Metal-on-metal prosthesis (n = 579) | Metal-on-polyethylene prosthesis (n = 1585) | ||||||
|---|---|---|---|---|---|---|---|---|
| 0-1 | 7 | 0.46 | 0.04-1.27 | 27 | 0.50 | 0.03-0.41*** | 0.91 | 0.98 - 1.163 |
| 2-9 | 75 | 0.81 | 0.62-1.32 | 193 | 0.70 | 0.61-0.96* | 1.16 | 0.88 - 1.52 |
| 10-19 | 103 | 0.85 | 0.86-1.59 | 326 | 0.97 | 0.67-1.02 | 0.87 | 0.69 - 1.10 |
| 20+ | 115 | 1.40 | 0.50-1.30 | 156 | 1.40 | 0.61-1.24 | 1.00 | 0.78 - 1.28 |
| Total | 300 | 0.96 | 0.78-1.18 | 702 | 0.90 | 0.66-0.87 *** | 1.07 | 0.93 - 1.22 |
‡ 95% CI, 95% confidence interval
*p < 0.05, **p < 0.01, *** p < 0.001