Literature DB >> 8769339

Cobalt and chromium concentrations in patients with metal on metal total hip replacements.

J J Jacobs1, A K Skipor, P F Doorn, P Campbell, T P Schmalzried, J Black, H C Amstutz.   

Abstract

There has been a resurgence of interest in the use of metal on metal bearings in total hip arthroplasty. Although the use of metal on metal bearing couples would eliminate or substantially reduce particulate polyethylene generation (depending on the presence or absence of polyethylene in the implant system), there is concern about the potential for increased particulate and ionic metal generation in comparison with polyethylene on metal bearings. These metallic degradation products may be transported away from the implant site and distributed systemically. Chromium concentrations in the serum and urine and cobalt concentrations in the serum were measured in subjects with cobalt chromium alloy metal on metal total hip replacements and in controls without implants. Eight subjects with long term (> 20 years) McKee-Farrar total hip replacements had 9-fold elevations in serum chromium, 35-fold elevations in urine chromium, and at least 3-fold elevations in serum cobalt concentrations in comparison with controls. Six subjects with short term (< 2 years) metal on metal surface replacement arthroplasties had 3-fold elevations in serum chromium, 4-fold elevations in urine chromium, and 4-fold elevations in serum cobalt concentrations in comparison with subjects with McKee-Farrar implants. Although the toxicologic importance of these trace metal elevations has not been established, serum and urine metal concentrations may be useful markers for the tribologic performance of metal on metal bearings.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8769339     DOI: 10.1097/00003086-199608001-00022

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  44 in total

1.  Improved mechanical long-term reliability of hip resurfacing prostheses by using silicon nitride.

Authors:  Wen Zhang; M Titze; B Cappi; D C Wirtz; R Telle; H Fischer
Journal:  J Mater Sci Mater Med       Date:  2010-08-20       Impact factor: 3.896

2.  Reduced articular surface of one-piece cups: a cause of runaway wear and early failure.

Authors:  William L Griffin; Christopher J Nanson; Bryan D Springer; Matthew A Davies; Thomas K Fehring
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

3.  [Allergic reactions as differential diagnosis for periprosthetic infection].

Authors:  H Meyer; A Krüger; A Roessner; C H Lohmann
Journal:  Orthopade       Date:  2012-01       Impact factor: 1.087

4.  Factors to consider in joint prosthesis systems.

Authors:  Larry M Wolford
Journal:  Proc (Bayl Univ Med Cent)       Date:  2006-07

5.  Investigating the immunologic effects of CoCr nanoparticles.

Authors:  Bamikole Ogunwale; Andreas Schmidt-Ott; R M Dominic Meek; James M Brewer
Journal:  Clin Orthop Relat Res       Date:  2009-06-30       Impact factor: 4.176

6.  [Reasons for failure of hip resurfacing implants. A failure analysis based on 250 revision specimens].

Authors:  M M Morlock; N Bishop; F Stahmer; J Zustin; G Sauter; M Hahn; M Krause; W Rüther; M Amling
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

7.  Wear of surface engineered metal-on-metal hip prostheses.

Authors:  J Fisher; X Q Hu; T D Stewart; S Williams; J L Tipper; E Ingham; M H Stone; C Davies; P Hatto; J Bolton; M Riley; C Hardaker; G H Isaac; G Berry
Journal:  J Mater Sci Mater Med       Date:  2004-03       Impact factor: 3.896

8.  [Surgical principles and clinical experiences with the DUROM hip resurfacing system using a lateral approach].

Authors:  Sascha Gravius; Torsten Mumme; Oliver Weber; Philipp Berdel; Dieter Christian Wirtz
Journal:  Oper Orthop Traumatol       Date:  2009-12       Impact factor: 1.154

9.  2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.

Authors:  C Anderson Engh; Steven J MacDonald; Supatra Sritulanondha; Abigail Thompson; Douglas Naudie; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

10.  A retrospective comparative study of mortality and causes of death among patients with metal-on-metal and metal-on-polyethylene total hip prostheses in primary osteoarthritis after a long-term follow-up.

Authors:  Tuomo Visuri; Håkan Borg; Pekka Pulkkinen; Pekka Paavolainen; Eero Pukkala
Journal:  BMC Musculoskelet Disord       Date:  2010-04-23       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.