Literature DB >> 20414136

Anatomical considerations for subaxial (C2) pedicle screw placement: a radiographic study with computed tomography in 93 patients.

Zachary A Smith1, Simona Bistazzoni, Adebukoa Onibokun, Nan-Fu Chen, Marco Sassi, Larry T Khoo.   

Abstract

STUDY
DESIGN: Radiographic study.
OBJECTIVE: More detailed anatomical knowledge of the C2 pedicle is required to optimize and minimize the risk of screw placement. The aim of this study was to evaluate the linear and angular dimensions of the true C2 pedicle using axial computed tomography. BACKGROUND DATA: Although earlier studies have analyzed the anatomy of the C2 pars interarticularis, little attention has been focused on the dimensions of the C2 pedicle.
METHODS: Ninety-three patients (47 males, 46 females; mean age 48.4 y) who had previous cervical spinal computed tomography imaging were evaluated for this study. Axial images of the C2 pedicle were selected and the following pedicle parameters were determined: pedicle width (the mediolateral diameter of the pedicle isthmus, perpendicular to the pedicle axis) and pedicle transverse angle (PTA, ie, the angle between the pedicle axis and the midline of the vertebral body).
RESULTS: The overall mean pedicle width was 5.8+/-1.2 mm. The mean pedicle width in male patients (6.0+/-1.3 mm) was greater than that in the female patients (5.6+/-1.1 mm). This difference was not found to be statistically significant (P=0.679). The overall mean PTA was 43.9+/-3.9 degrees. The mean PTA in male patients was 43.2+/-3.8 degrees, whereas that in female patients was 44.7+/-3.7 degrees.
CONCLUSIONS: Given the significant variability in pedicle widths and the need for precise trajectory planning in pedicle cannulation, preoperative planning is absolutely mandatory. A significant percentage of patients have pedicle widths that may not accommodate screw fixation. In addition, the angle of entry into the C2 pedicle must be carefully measured for safe instrumentation at this level.

Entities:  

Mesh:

Year:  2010        PMID: 20414136     DOI: 10.1097/BSD.0b013e3181b40234

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  13 in total

1.  CT analysis of C2 pedicles morphology and considerations of useful parameters for screwing.

Authors:  Mourad Ould-Slimane; Sebastien Le Pape; Julien Leroux; Emmanuel Foulongne; Camille Damade; Franck Dujardin; Fabrice Duparc
Journal:  Surg Radiol Anat       Date:  2013-11-16       Impact factor: 1.246

2.  A clinical morphologic study of the C2 pedicle and isthmus.

Authors:  Feng Yuan; Hui-Lin Yang; Kai-Jin Guo; Jiang-Shan Li; Kai Xu; Zhi-Ming Zhang; Tian-Si Tang
Journal:  Eur Spine J       Date:  2012-08-14       Impact factor: 3.134

3.  Management of hangman's fracture with percutaneous transpedicular screw fixation.

Authors:  Yao-Sen Wu; Yan Lin; Xiao-Lei Zhang; Nai-Feng Tian; Liao-Jun Sun; Hua-Zi Xu; Yong-Long Chi; Zhi-Jun Pan
Journal:  Eur Spine J       Date:  2012-11-19       Impact factor: 3.134

4.  Inferolateral entry point for c2 pedicle screw fixation in high cervical lesions.

Authors:  Kwang Ho Lee; Dong Ho Kang; Chul Hee Lee; Soo Hyun Hwang; In Sung Park; Jin Myung Jung
Journal:  J Korean Neurosurg Soc       Date:  2011-10-31

5.  Short isthmic versus long trans-isthmic C2 screw: anatomical and biomechanical evaluation.

Authors:  François Lucas; David Mitton; Bertrand Frechede; Cédric Barrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-05-12

6.  Anterior pedicle screw fixation of C2: an anatomic analysis of axis morphology and simulated surgical fixation.

Authors:  Zeng-Hui Wu; Yi Zheng; Qing-Shui Yin; Xiang-Yang Ma; Yi-Hong Yin
Journal:  Eur Spine J       Date:  2014-02       Impact factor: 3.134

7.  Anatomical analysis of the C2 pedicle in patients with basilar invagination.

Authors:  Ruipei Xiao; Juedong Hou; Yang Zhou; Jintao Zheng; Xiaobao Zou; Yongjian Zhu; Ling Yao; Xiangyang Ma; Jianting Chen; Jincheng Yang
Journal:  Eur Spine J       Date:  2022-05-23       Impact factor: 2.721

8.  Morphological and clinical feasibility of C3 pedicle screw instrumentation in patients with congenital C2-3 fusion.

Authors:  Peng Xiu; Qing Wang; Gaoju Wang; Song Wang; Guidong Dai; Yongshu Lan
Journal:  Eur Spine J       Date:  2014-06-04       Impact factor: 3.134

9.  The Anterior Transarticular Fixation of C1/C2 in the Elderly With Dens Fractures.

Authors:  Oliver Gembruch; Yahya Ahmadipour; Elias Lemonas; Oliver Müller
Journal:  Int J Spine Surg       Date:  2020-04-30

10.  Feasibility of C2 Vertebra Screws Placement in Patient With Occipitalization of Atlas: A Tomographic Study.

Authors:  Wei Ji; Xiang Liu; Wenhan Huang; Zucheng Huang; Xueshi Li; Jianting Chen; Zenghui Wu; Qingan Zhu
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.