Literature DB >> 20407752

Correlation of radiographic and navigated measurements of TKA limb alignment: a matter of time?

Oliver Hauschild1, Lukas Konstantinidis, Tobias Baumann, Philipp Niemeyer, Norbert P Suedkamp, Peter Helwig.   

Abstract

Valid and reproducible measurements of limb alignment are prerequisites for planning, performing and evaluating TKAs. Although navigation systems have been shown to be reproducible tool for intraoperative TKA alignment measurements, particular doubt has been raised on the correlation with postoperative radiographic measurements. The aim of the present study was to evaluate whether the association of postoperative radiographic and navigation measurements of limb alignment was dependent on the time of acquisition. For this purpose, we retrospectively compared two groups of patients who underwent computer-assisted cemented TKA for osteoarthritis of the knee. Intraoperative navigation measurements (OrthoPilot™, Aesculap, Tuttlingen, Germany) were recorded before any cuts were made and again after implants had been placed. Long leg standing radiographs were acquired preoperatively in both the groups and either 2 weeks or 3 months postoperatively and AP limb alignment measurements were correlated with those of the respective navigation assessments. Preoperative deformity was similar in both the groups and correlation between radiographic and navigation measurements was excellent in both groups (ρ = 0.845 and 0.945, respectively). However, both mean and maximum discrepancies between radiographic and navigation measurements of leg alignment were significantly larger when radiographs were obtained 2 weeks (2.6° ± 2.1°, max. 10°) when compared with 3 months (1.8° ± 1.4°, max. 5°) postoperatively (P = 0.026). Accordingly, correlation between radiographic and navigation measurements was poor when radiographs were obtained 2 weeks postoperatively (ρ = 0.26, n.s.) but in the range of preoperative assessments when obtained 3 months postoperatively (ρ = 0.841, P < 0.001). Radiographic and navigation measurements of TKA limb alignment correlate well preoperatively. Equally good correlations can only be achieved when postoperative radiographic measurements are delayed to a time when more patients achieve full or near-full extension and are able to bear full weight leading to more valid radiographs.

Entities:  

Mesh:

Year:  2010        PMID: 20407752     DOI: 10.1007/s00167-010-1144-y

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  31 in total

1.  Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; C Perlick; J Grifka
Journal:  Int Orthop       Date:  2004-01-17       Impact factor: 3.075

2.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

3.  Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images.

Authors:  Adrian V Specogna; Trevor B Birmingham; Jerome J DaSilva; Jaques S Milner; Jacqueline Kerr; Michael A Hunt; Ian C Jones; Thomas R Jenkyn; Peter J Fowler; J Robert Giffin
Journal:  J Knee Surg       Date:  2004-10       Impact factor: 2.757

4.  Navigated lower limb axis measurements: Influence of mechanical weight-bearing simulation.

Authors:  Daniel Kendoff; Timothy N Board; Musa Citak; Michael J Gardner; Stefan Hankemeier; Sven Ostermeier; Christian Krettek; Tobias Hüfner
Journal:  J Orthop Res       Date:  2008-04       Impact factor: 3.494

5.  Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty.

Authors:  W P Yau; Anthony Leung; K G Liu; C H Yan; Lisa L S Wong; K Y Chiu
Journal:  J Arthroplasty       Date:  2007-12       Impact factor: 4.757

6.  A quantitative approach to radiography of the lower limb. Principles and applications.

Authors:  T D Cooke; R A Scudamore; J T Bryant; C Sorbie; D Siu; B Fisher
Journal:  J Bone Joint Surg Br       Date:  1991-09

7.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations.

Authors:  J H Bargren; J D Blaha; M A Freeman
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

Review 8.  [Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies].

Authors:  H Bäthis; S Shafizadeh; T Paffrath; C Simanski; J Grifka; C Lüring
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

9.  Do we get a "real" alignment of knee in the preoperative planning of high tibia osteotomy: a prospective study of reproducibility.

Authors:  Teng-Le Huang; Hung-Ta Hondar Wu; Juhn-Cherny Liu; Wei-Ming Chen; Tain-Hsiung Chen
Journal:  J Chin Med Assoc       Date:  2004-04       Impact factor: 2.743

10.  Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs.

Authors:  J Sailer; M Scharitzer; P Peloschek; A Giurea; H Imhof; S Grampp
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315

View more
  11 in total

1.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

2.  Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique.

Authors:  Kilian Reising; Peter C Strohm; Oliver Hauschild; Hagen Schmal; Mohmed Khattab; Norbert P Südkamp; Philipp Niemeyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-04       Impact factor: 4.342

3.  Agreement between radiological and computer navigation measurement of lower limb alignment.

Authors:  Julian Dexel; Stephan Kirschner; Klaus-Peter Günther; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-06       Impact factor: 4.342

Review 4.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

5.  Does the severity of preoperative varus deformity influence postoperative alignment in both conventional and computer-assisted total knee arthroplasty?

Authors:  Dae Kyung Bae; Sang Jun Song; Dong Beom Heo; Dae Hyun Tak
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-10-30       Impact factor: 4.342

Review 6.  [The Berlin diagnostic algorithm for painful knee TKA].

Authors:  K Thiele; J Fussi; C Perka; T Pfitzner
Journal:  Orthopade       Date:  2016-01       Impact factor: 1.087

7.  Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA?

Authors:  Marrigje F Meijer; Alexander L Boerboom; Sjoerd K Bulstra; Inge H F Reininga; Martin Stevens
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-25       Impact factor: 4.342

8.  Preliminary experience with the patient-specific templating total knee arthroplasty.

Authors:  Bert Boonen; Martijn G M Schotanus; Nanne P Kort
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717

9.  Influence of navigation system updates on total knee arthroplasty.

Authors:  Hiroshi Inui; Shuji Taketomi; Kensuke Nakamura; Seira Takei; Hideki Takeda; Sakae Tanaka; Takumi Nakagawa
Journal:  BMC Sports Sci Med Rehabil       Date:  2013-05-02

10.  Measurement of lower limb alignment: there are within-person differences between weight-bearing and non-weight-bearing measurement modalities.

Authors:  Daphne A L Schoenmakers; Peter Z Feczko; Bert Boonen; Martijn G M Schotanus; Nanne P Kort; Pieter J Emans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-18       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.