Literature DB >> 20407114

Polymer-free biolimus a9-coated stent demonstrates more sustained intimal inhibition, improved healing, and reduced inflammation compared with a polymer-coated sirolimus-eluting cypher stent in a porcine model.

Norio Tada1, Renu Virmani, Gordon Grant, Lauren Bartlett, Alexander Black, Claudia Clavijo, Uwe Christians, Ron Betts, Doug Savage, Shih-Horng Su, John Shulze, Saibal Kar.   

Abstract

BACKGROUND: Drug-eluting stents effectively reduce restenosis but may increase late thrombosis and delayed restenosis. Persistent polymer, the drug, or a combination of both could be responsible. Local delivery of Biolimus A9, a rapamycin derivative, from a polymer-free BioFreedom stent (Biosensors International) may prevent these complications. METHODS AND
RESULTS: We compared high-dose (HD) (225 microg/14 mm Biolimus A9) and low-dose (LD) (112 microg/14 mm Biolimus A9) BioFreedom stents with a polymer-coated sirolimus-eluting Cypher stent (SES) and a bare-metal stent (BMS) at 28 days and 180 days in an overstretch coronary mini-swine model with histomorphometric and histological analysis. At 28 days, there was a reduction in neointimal proliferation by HD, LD, and SES compared with BMS (neointimal thickness: HD, 0.080+/-0.032; LD, 0.085+/-0.038; SES, 0.064+/-0.037; BMS, 0.19+/-0.111 mm; P<0.001; BMS > HD/LD/SES). At 180 days, both BioFreedom stents were associated with reduced neointimal proliferation, whereas SES exhibited increased neointima (neointimal thickness: HD, 0.12+/-0.034; LD, 0.10+/-0.040; SES, 0.20+/-0.111; BMS, 0.17+/-0.099 mm; P<0.001; SES > HD/LD; BMS > LD). At 180 days, BioFreedom stents showed decreased fibrin and inflammation, including granuloma and giant cells, compared with SES.
CONCLUSIONS: The polymer-free Biolimus A9-coated stent demonstrates equivalent early and superior late reduction of intimal proliferation compared with SES in a porcine model. After implantation of BioFreedom stent, delayed arterial healing was minimal, and there was no increased inflammation at 180 days compared with SES implantation. The use of polymer-free stents may have a potential long-term benefit over traditional polymeric-coated drug-eluting stents.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20407114     DOI: 10.1161/CIRCINTERVENTIONS.109.877522

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  25 in total

Review 1.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

2.  One-year clinical outcomes of BioMatrix™-Biolimus A9™ eluting stent: the e-BioMatrix multicenter post marketing surveillance registry in India.

Authors:  Ashwin B Mehta; Praveen Chandra; Jamshed Dalal; Prabhakar Shetty; Devang Desai; K Chocklingam; Jayesh Prajapati; Pramod Kumar; Vilas Magarkar; Apurva Vasawada; B K Goyal; Viveka Kumar; V Suryaprakash Rao; Ramesh Babu; Pritesh Parikh; Upendra Kaul; Aruna Patil; Tushar Mhetre; Hrishikesh Rangnekar
Journal:  Indian Heart J       Date:  2013-09-23

3.  A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries.

Authors:  Celso K Takimura; Micheli Z Galon; Paulo S Gutierrez; Prakash Sojitra; Ashwin Vyas; Manish Doshi; Pedro A Lemos
Journal:  Cardiovasc Diagn Ther       Date:  2015-04

Review 4.  Enhancing Stent Effectiveness with Nanofeatures.

Authors:  Nicole Bassous; John P Cooke; Thomas J Webster
Journal:  Methodist Debakey Cardiovasc J       Date:  2016-09

Review 5.  Polymer-Free Drug-Coated Coronary Stents in Patients with Stable Coronary Artery Disease at High Bleeding Risk.

Authors:  Hemang B Panchal; Ramesh Daggubati; David Zhao; Sunil V Rao; Timir Paul
Journal:  Curr Cardiol Rep       Date:  2017-02       Impact factor: 2.931

Review 6.  Drug-eluting stents and acute myocardial infarction: A lethal combination or friends?

Authors:  Shuji Otsuki; Manel Sabaté
Journal:  World J Cardiol       Date:  2014-09-26

7.  Polymer-free drug-coated vs. bare-metal coronary stents in patients undergoing non-cardiac surgery: a subgroup analysis of the LEADERS FREE trial.

Authors:  Gert Richardt; Mohammad Abdelghani; Abdelhakim Allali; Ralph Toelg; Mohamed Abdellaoui; Florian Krackhardt; Rune Wiseth; Marie-Claude Morice; Samuel Copt; Hans-Peter Stoll; Philip Urban
Journal:  Clin Res Cardiol       Date:  2020-05-21       Impact factor: 5.460

Review 8.  New concepts in the design of drug-eluting coronary stents.

Authors:  Scot Garg; Christos Bourantas; Patrick W Serruys
Journal:  Nat Rev Cardiol       Date:  2013-02-19       Impact factor: 32.419

Review 9.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

10.  Stent thrombosis: understanding and managing a critical problem.

Authors:  Julio F Marchini; Andre Manica; Kevin Croce
Journal:  Curr Treat Options Cardiovasc Med       Date:  2012-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.