Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement.

Sabine Bleiziffer1, Ayyaz Ali, Ina M Hettich, Deniz Akdere, Rüdiger P Laubender, Daniel Ruzicka, Johannes Boehm, Rüdiger Lange, Walter Eichinger.   

Abstract

BACKGROUND: There has been ongoing controversy as to whether prosthesis-patient mismatch (PPM, defined as indexed effective orifice area (EOAI) <0.85 m(2)/cm(2)) influences mortality after aortic valve replacement (AVR). In most studies, PPM is anticipated by reference tables based on mean EOAs as opposed to individual assessment. These reference values may not reflect the actual in vivo EOAI and hence, the presence or absence of PPM may be based on false assumptions.
OBJECTIVE: To assess the impact of small prosthesis EOA on survival after aortic valve replacement AVR.
METHODS: 645 patients had undergone an AVR between 2000 and 2007 entered the study. All patients underwent transthoracic echocardiography for determination of the actual EOAI within 6 months postoperatively. In order to predict time from surgery to death a proportional hazards model for competing risks (cardiac death vs death from other causes) was used. EOAI was entered as a continuous variable.
RESULTS: PPM occurred in 40% of the patients. After a median follow-up of 2.35 years, 92.1% of the patients were alive. The final Cox regression model showed a significantly increased risk for cardiac death among patients with a smaller EOAI (HR=0.32, p=0.022). The effect of EOAI on the 2-5 year mortality risk was demonstrated by risk plots.
CONCLUSIONS: In contrast to previous studies these EOAI values were obtained through postoperative echocardiography, substantially improving the accuracy of measurement, and the EOAI was modelled as a continuous variable. There was a significantly improved survival for larger EOAIs following AVR. Strategies to avoid PPM should become paramount during AVR.

Entities:  

Mesh:

Year:  2010        PMID: 20406767     DOI: 10.1136/hrt.2009.177220

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  10 in total

1.  Impact of New York Heart Association classification, advanced age and patient-prosthesis mismatch on outcomes in aortic valve replacement surgery.

Authors:  Alex Zapolanski; Andrew W C Mak; Giovanni Ferrari; Christopher Johnson; Richard E Shaw; Mariano E Brizzio; Jason S Sperling; Juan B Grau
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-06-04

Review 2.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

3.  Early and late outcomes of AVR with aortic annular enlargement in octogenarian.

Authors:  Yuki Okamoto; Kazuo Yamamoto; Tsutomu Sugimoto; Shinpei Yoshii
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-05-14

4.  Improvement of left ventricular longitudinal systolic function after transcatheter aortic valve implantation: a speckle-tracking prospective study.

Authors:  Flavio D'Ascenzi; Matteo Cameli; Alessandro Iadanza; Matteo Lisi; Valerio Zacà; Rosanna Reccia; Valeria Curci; Andrea Torrisi; Giuseppe Sinicropi; Carlo Pierli; Sergio Mondillo
Journal:  Int J Cardiovasc Imaging       Date:  2012-12-28       Impact factor: 2.357

Review 5.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

Review 6.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

7.  Patient Prosthesis Mismatch After SAVR and TAVR.

Authors:  Sabine Bleiziffer; Tanja K Rudolph
Journal:  Front Cardiovasc Med       Date:  2022-03-30

8.  Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement.

Authors:  Bart M Koene; Mohamed A Soliman Hamad; Wobbe Bouma; Massimo A Mariani; Kathinka C Peels; Jan-Melle van Dantzig; Albert H van Straten
Journal:  J Cardiothorac Surg       Date:  2013-04-17       Impact factor: 1.637

9.  Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

Authors:  Jia Hu; Hong Qian; Ya-jiao Li; Jun Gu; Jing Janice Zhao; Er-yong Zhang
Journal:  J Cardiothorac Surg       Date:  2014-01-17       Impact factor: 1.637

10.  Rapid deployment valve system shortens operative times for aortic valve replacement through right anterior minithoracotomy.

Authors:  Constanze Bening; Khaled Hamouda; Mehmet Oezkur; Christoph Schimmer; Ina Schade; Armin Gorski; Ivan Aleksic; Rainer Leyh
Journal:  J Cardiothorac Surg       Date:  2017-05-16       Impact factor: 1.637

  10 in total