Literature DB >> 20406742

Relationship between radiographic techniques (kilovolt and milliampere-second) and CTDI(VOL).

Saeed Elojeimy1, Sameer Tipnis, Walter Huda.   

Abstract

To investigate the relationship between radiographic techniques (i.e. kilovolt and milliampere-second) and the corresponding volume computed tomography dose index (CTDI(vol)). Data were obtained for CTDI(vol) for head and body phantoms from the ImPACT CT patient dosimetry calculator for 43 scanners from four major vendors of medical imaging equipment (i.e. GE, Philips, Siemens and Toshiba). CTDI(vol) were obtained with the largest X-ray beam width, and using a CT pitch of unity. For each scanner, relative values of CTDI(vol) were also computed as a function of X-ray tube voltage, normalised to unity at 120 kV. The average CTDI(vol) for 43 commercial scanners was 167 + or - 44 microGy (mA s)(-1) for the head phantom and 78 + or - 22 microGy (mA s)(-1) for the body phantom. The 90th percentile CTDI(vol) values are approximately twice the corresponding 10th percentile values for both head and body phantoms. Over the last 20 y, the head phantom CTDI(vol) has increased approximately 50 % and the body phantom CTDI(vol) has increased approximately 90 %. For both, the head phantom and the body phantom, CTDI(vol) is proportional to kilovolt(2.6). CT output must be specified using CTDI(vol) because for a fixed kilovolt and milliampere-second, CT scanner outputs (CTDI(vol)) differ by about a factor of 2. Increasing the X-ray tube voltage from 80 to 140 kV increases CTDI(vol) by about a factor of 4.

Entities:  

Mesh:

Year:  2010        PMID: 20406742     DOI: 10.1093/rpd/ncq138

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  9 in total

1.  Radiation dose to the fetus from [(18)F]-FDG administration during the second trimester of pregnancy.

Authors:  Paolo Zanotti-Fregonara; Thomas M Koroscil; Joseph Mantil; Martin Satter
Journal:  Health Phys       Date:  2012-02       Impact factor: 1.316

2.  Reaching for better image quality and lower radiation dose in head and neck CT: advanced modeled and sinogram-affirmed iterative reconstruction in combination with tube voltage adaptation.

Authors:  Andrea I Schmid; Michael Uder; Michael M Lell
Journal:  Dentomaxillofac Radiol       Date:  2016-09-08       Impact factor: 2.419

3.  Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE).

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Seitaro Oda; Takeshi Nakaura; Yoshinori Funama; Hideaki Yuki; Kenichiro Hirata; Tomohiro Namimoto; Daisuke Sakabe; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2016-10-07       Impact factor: 5.315

4.  Deep Learning-Based Reconstruction vs. Iterative Reconstruction for Quality of Low-Dose Head-and-Neck CT Angiography with Different Tube-Voltage Protocols in Emergency-Department Patients.

Authors:  Marc Lenfant; Pierre-Olivier Comby; Kevin Guillen; Felix Galissot; Karim Haioun; Anthony Thay; Olivier Chevallier; Frédéric Ricolfi; Romaric Loffroy
Journal:  Diagnostics (Basel)       Date:  2022-05-21

5.  Optimizing CT technique to reduce radiation dose: effect of changes in kVp, iterative reconstruction, and noise index on dose and noise in a human cadaver.

Authors:  Kevin J Chang; Scott Collins; Baojun Li; William W Mayo-Smith
Journal:  Radiol Phys Technol       Date:  2016-10-03

6.  Validity of the size-specific dose estimate in adults undergoing coronary CT angiography: comparison with the volume CT dose index.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Noriyuki Kai; Takeshi Nozaki; Yasuyuki Yamashita
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-06       Impact factor: 2.357

7.  Pilot study on image quality and radiation dose of CT colonography with adaptive iterative dose reduction three-dimensional.

Authors:  Hesong Shen; Dan Liang; Mingyue Luo; Chaijie Duan; Wenli Cai; Shanshan Zhu; Jianping Qiu; Wenru Li
Journal:  PLoS One       Date:  2015-01-30       Impact factor: 3.240

8.  Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D).

Authors:  Hesong Shen; Guochao Dai; Mingyue Luo; Chaijie Duan; Wenli Cai; Dan Liang; Xinhua Wang; Dongyun Zhu; Wenru Li; Jianping Qiu
Journal:  PLoS One       Date:  2015-11-23       Impact factor: 3.240

9.  Quality control of CT systems by automated monitoring of key performance indicators: a two-year study.

Authors:  Patrik Nowik; Robert Bujila; Gavin Poludniowski; Annette Fransson
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.