Literature DB >> 20393730

[Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

U Mester1, S Heinen, H Kaymak.   

Abstract

BACKGROUND: Aspheric intraocular lenses (IOLs) aim to improve visual function and particularly contrast vision by neutralizing spherical aberration. One drawback of such IOLs is the enhanced sensitivity to decentration and tilt, which can deteriorate image quality.
METHODS: A total of 30 patients who received bilateral phacoemulsification before implantation of the aspheric lens FY-60AD (Hoya) were included in a prospective study. In 25 of the patients (50 eyes) the following parameters could be assessed 3 months after surgery: visual acuity, refraction, contrast sensitivity, pupil size, wavefront errors and decentration and tilt using a newly developed device.
RESULTS: The functional results were very satisfying and comparable to results gained with other aspheric IOLs. The mean refraction was sph + 0.1 D (±0.7 D) and cyl 0.6 D (±0.8 D). The spherical equivalent was −0.2 D (±0.6 D). Wavefront measurements revealed a good compensation of the corneal spherical aberration but vertical and horizontal coma also showed opposing values in the cornea and IOL. The assessment of the lens position using the Purkinje meter demonstrated uncritical amounts of decentration and tilt. The mean amount of decentration was 0.2 mm±0.2 mm in the horizontal and vertical directions. The mean amount of tilt was 4.0±2.1° in horizontal and 3.0±2.5° in vertical directions.
CONCLUSIONS: In a normal dioptric power range the aspheric IOL FY-60AD compensates the corneal spherical aberration very well with only minimal decentration. The slight tilt is symmetrical in both eyes and corresponds to the position of the crystalline lens in young eyes. This may contribute to our findings of compensated corneal coma.

Entities:  

Mesh:

Year:  2010        PMID: 20393730     DOI: 10.1007/s00347-009-2102-2

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  23 in total

1.  Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic intraocular lenses with 6-mm optics in an intraindividual comparison.

Authors:  Martin Baumeister; Barbara Neidhardt; Jürgen Strobel; Thomas Kohnen
Journal:  Am J Ophthalmol       Date:  2005-12       Impact factor: 5.258

2.  Balance of corneal horizontal coma by internal optics in eyes with intraocular artificial lenses: evidence of a passive mechanism.

Authors:  Susana Marcos; Patricia Rosales; Lourdes Llorente; Sergio Barbero; I Jiménez-Alfaro
Journal:  Vision Res       Date:  2007-12-03       Impact factor: 1.886

3.  Relationship between contrast sensitivity and spherical aberration: comparison of 7 contrast sensitivity tests with natural and artificial pupils in healthy eyes.

Authors:  Kim W van Gaalen; Nomdo M Jansonius; Steven A Koopmans; Thom Terwee; Aart C Kooijman
Journal:  J Cataract Refract Surg       Date:  2009-01       Impact factor: 3.351

Review 4.  Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.

Authors:  Robert Montés-Micó; Teresa Ferrer-Blasco; Alejandro Cerviño
Journal:  J Cataract Refract Surg       Date:  2009-01       Impact factor: 3.351

5.  Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes.

Authors:  Frank Schaeffel
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-05       Impact factor: 4.799

6.  Impact of a modified optic design on visual function: clinical comparative study.

Authors:  Ulrich Mester; Patrick Dillinger; Nicola Anterist
Journal:  J Cataract Refract Surg       Date:  2003-04       Impact factor: 3.351

7.  Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study.

Authors:  Patrick F Tzelikis; Leonardo Akaishi; Fernando C Trindade; Joel E Boteon
Journal:  Am J Ophthalmol       Date:  2008-03-04       Impact factor: 5.258

8.  Mechanism of compensation of aberrations in the human eye.

Authors:  Juan Tabernero; Antonio Benito; Encarna Alcón; Pablo Artal
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-10       Impact factor: 2.129

9.  Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses.

Authors:  K Hayashi; H Hayashi; F Nakao; F Hayashi
Journal:  Br J Ophthalmol       Date:  1998-04       Impact factor: 4.638

10.  Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyes.

Authors:  Ulrich Mester; Thomas Sauer; Hakan Kaymak
Journal:  J Cataract Refract Surg       Date:  2009-03       Impact factor: 3.351

View more
  1 in total

1.  [Investigation of the theoretical image quality of aspheric intraocular lenses by decentration. Hoya AF-1 iMics1 und Zeiss ASPHINA(TM) (Invent ZO)].

Authors:  M Gillner; A Langenbucher; T Eppig
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.