Literature DB >> 16376650

Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic intraocular lenses with 6-mm optics in an intraindividual comparison.

Martin Baumeister1, Barbara Neidhardt, Jürgen Strobel, Thomas Kohnen.   

Abstract

PURPOSE: Intraindividual comparison of tilt and decentration of three-piece foldable intraocular lenses (IOLs) with 6-mm optics and different edge design and material.
DESIGN: Prospective randomized study.
METHODS: Twenty-five patients with senile cataract (group I) received a foldable silicone, sharp optic edge IOL in one eye and a silicone, rounded optic edge IOL in the other eye. Group II (n = 28) received the foldable silicone, sharp optic edge IOL in one eye and an acrylate, sharp optic edge IOL in the other eye. Scheimpflug photography was performed after the procedure with an anterior eye segment analysis system. Tilt and decentration of the IOL optic were measured 1 week, 6 months, and 12 months after the procedure.
RESULTS: In group I, the foldable silicone, sharp optic edge IOL showed a mean optic tilt of 3.03 +/- 1.79 degrees and an optic decentration of 0.24 +/- 0.13 mm; the silicone, rounded optic edge IOL showed a tilt of 3.26 +/- 1.69 degrees and a decentration of 0.23 +/- 0.13 mm. In group II, the foldable silicone, sharp optic edge IOL showed an average tilt of 2.34 +/- 1.81 degrees and a decentration of 0.29 +/- 0.21 mm after 12 months; the acrylate, sharp optic edge IOL had a tilt of 2.32 +/- 1.41 degrees and a decentration of 0.24 +/- 0.10 mm. There were no significant differences in either group.
CONCLUSION: The examined IOLs showed a stable position regarding tilt and decentration in the first 12 postoperative months, independent of material and edge design. Slight deviations from the optical axis might affect the outcome in aspheric or multifocal IOLs.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16376650     DOI: 10.1016/j.ajo.2005.07.026

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  13 in total

1.  [Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

Authors:  U Mester; S Heinen; H Kaymak
Journal:  Ophthalmologe       Date:  2010-09       Impact factor: 1.059

2.  Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration.

Authors:  T Oshika; G Sugita; K Miyata; T Tokunaga; T Samejima; C Okamoto; Y Ishii
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

3.  Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Authors:  Wenwen He; Xiaodi Qiu; Shaohua Zhang; Yu Du; Yinglei Zhang; Yi Lu; Xiangjia Zhu
Journal:  Eye (Lond)       Date:  2018-03-09       Impact factor: 3.775

4.  Femtosecond laser-assisted cataract surgery versus conventional phacoemulsification: comparison of internal aberrations and visual quality.

Authors:  Yueyang Zhong; Yanan Zhu; Wei Wang; Kai Wang; Xin Liu; Ke Yao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-10-12       Impact factor: 3.117

5.  Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study.

Authors:  Lingling Niu; Zhe Zhang; Huamao Miao; Jing Zhao; Meiyan Li; Ji C He; Peijun Yao; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2022-07-05       Impact factor: 2.086

6.  Dissatisfaction after multifocal intraocular lens implantation.

Authors:  Maria A Woodward; J Bradley Randleman; R Doyle Stulting
Journal:  J Cataract Refract Surg       Date:  2009-06       Impact factor: 3.351

7.  [Cataract surgery in glaucoma patients. Perioperative aspects].

Authors:  T S Dietlein; T Kohnen; A Rosentreter; A Lappas
Journal:  Ophthalmologe       Date:  2013-04       Impact factor: 1.059

8.  Stability of Various Types of Aspheric Intraocular Lenses After Implantation: A One-Year Retrospective Study.

Authors:  Yuan Ning; Yushuang Shao; Jiangyue Zhao; Jinsong Zhang; Mingwu Wang; Yu Qin
Journal:  Int J Gen Med       Date:  2021-06-01

9.  Post-operative capsular opacification: a review.

Authors:  Shetal M Raj; Abhay R Vasavada; S R Kaid Johar; Vaishali A Vasavada; Viraj A Vasavada
Journal:  Int J Biomed Sci       Date:  2007-12

10.  IOL tilt and decentration estimation from 3 dimensional reconstruction of OCT image.

Authors:  Xiaogang Wang; Jing Dong; Xiaoliang Wang; Qiang Wu
Journal:  PLoS One       Date:  2013-03-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.