Literature DB >> 20382040

Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component.

Sandro F Fucentese1, John G Costouros, Stefanie-Peggy Kühnel, Christian Gerber.   

Abstract

BACKGROUND: Loosening associated with cemented polyethylene glenoid components is a major concern following total shoulder arthroplasty (TSA). The purpose of this study was to investigate the clinical and radiographic results associated with use of a novel uncemented soft-metal-backed glenoid component (SMBG), with a minimum follow-up of 2 years.
MATERIALS AND METHODS: Twenty-two patients (19 women) underwent TSA using a uncemented SMBG. The mean age was 68.5 years (range, 49-84). Mean follow-up was 50 months (range, 24-89). Indications for TSA were primary osteoarthritis (10), post-traumatic osteoarthritis (8), steroid-induced avascular necrosis (2), crystalline arthropathy (1), and arthritis secondary to systemic lupus erythematodes (1). Subjective and objective parameters were assessed. Loosening and polyethylene wear were evaluated.
RESULTS: Mean absolute Constant scores improved from 29.1 to 65.9 points (P < .001), age- and sex-adjusted Constant scores improved from 40.1 to 87.7% (P < .001), and subjective shoulder values improved from 35% to 75.2% (P < .001). Mean pain scores improved from 4.2 points to 13.1 (P < .001). Three cases had a fractured glenoid component. Only these 3 had a definite loosening. Polyethylene wear was found in 2 cases.
CONCLUSION: Use of an uncemented SMBG component yields controversial results. Osteointegration appears possible and loosening signs have virtually not been observed. Conversely, the current implant can be associated with a high failure rate (13.6%) because of implant fractures despite short follow-up. As loosening seems absent or minimal but implant stability insufficient, design changes need to be performed and tested in view of solving the implant failure problem while preserving the actually excellent bone-implant interface characteristics. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20382040     DOI: 10.1016/j.jse.2009.12.021

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  18 in total

1.  Metallosis following a dual coat porous hydroxyapatite shoulder hemiarthroplasty.

Authors:  Humza Khan; Mark Hurworth; Alan Kop
Journal:  J Orthop       Date:  2015-03-12

2.  Prospective midterm results of a new convertible glenoid component in anatomic shoulder arthroplasty: a cohort study.

Authors:  Petra Magosch; Sven Lichtenberg; Mark Tauber; Frank Martetschläger; Peter Habermeyer
Journal:  Arch Orthop Trauma Surg       Date:  2020-04-23       Impact factor: 3.067

Review 3.  Journey of the glenoid in anatomic total shoulder replacement.

Authors:  Alessandro Castagna; Raffaele Garofalo
Journal:  Shoulder Elbow       Date:  2018-08-01

4.  Metallosis in shoulder arthroplasty: an integrative review of literature.

Authors:  Paritosh Gogna; Paolo Paladini; Giovanni Merolla; Carlo Alberto Augusti; De Falco Maddalena; Giuseppe Porcellini
Journal:  Musculoskelet Surg       Date:  2016-11-30

5.  No differences in early results of a hybrid glenoid compared with a pegged implant.

Authors:  Lawrence V Gulotta; K Lauchlan Chambers; Russell F Warren; David M Dines; Edward V Craig
Journal:  Clin Orthop Relat Res       Date:  2015-09-09       Impact factor: 4.176

6.  Radiographic and clinical outcomes of second generation Trabecular Metal™ glenoid components in total shoulder arthroplasty.

Authors:  Raymond E Chen; Alexander M Brown; Alexander S Greenstein; Sandeep Mannava; Ilya Voloshin
Journal:  Shoulder Elbow       Date:  2020-03-24

7.  Porous metals and alternate bearing surfaces in shoulder arthroplasty.

Authors:  Shannon R Carpenter; Ivan Urits; Anand M Murthi
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

8.  Cement pressurizing reduces radiolucent lines at glenoid: A randomized, multicentric study.

Authors:  Philip Kasten; Patric Raiss; Felix Zeifang; Richard Stangl; Stefan Greiner; Matthias Zumstein; Jörg Nowotny; Katrin Schmitt; Marc Schnetzke; Falk Reuther; Dirk Frauenschuh
Journal:  Shoulder Elbow       Date:  2019-08-01

9.  Short-term rates of radiolucency after primary total shoulder arthroplasty using a cementless metal-backed pegged polyethylene glenoid.

Authors:  Khalid Al-Hourani; James R Smith; Mark A Crowther; Partha Sarangi; Philip A McCann
Journal:  Shoulder Elbow       Date:  2018-08-06

Review 10.  The Clinical Application of Porous Tantalum and Its New Development for Bone Tissue Engineering.

Authors:  Gan Huang; Shu-Ting Pan; Jia-Xuan Qiu
Journal:  Materials (Basel)       Date:  2021-05-18       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.