Literature DB >> 33343711

Short-term rates of radiolucency after primary total shoulder arthroplasty using a cementless metal-backed pegged polyethylene glenoid.

Khalid Al-Hourani1, James R Smith1, Mark A Crowther2, Partha Sarangi1, Philip A McCann1.   

Abstract

BACKGROUND: Total shoulder arthroplasty has shown good clinical efficacy in treating primary and secondary degenerative conditions of the glenohumeral joint. Glenoid loosening, however, remains the commonest cause of failure. The purpose of this study was to investigate the rate of radiographic periprosthetic lucency associated with the use of an uncemented, pegged, metal-backed polyethylene glenoid component.
MATERIALS AND METHODS: A retrospective, single-centre study using the Epoca (Synthes, Paoli, Pennsylvania) metal-backed glenoid component. Operations were performed by two experienced consultant upper limb surgeons. Radiographs were analysed for immediate post-operative component seating and periprosthetic radiolucent lines at predefined regular post-operative intervals. Intra- and inter-observer reliability was assessed to improve validity of results.
RESULTS: Mean age and follow-up was 72 (48-91) years and 2.5 years (2-5), respectively. Main indications for total shoulder arthroplasty were primary osteoarthritis, rheumatoid arthritis, revision for failed hemi-arthroplasty and acute fracture. Ninety-six per cent of components were completely seated post-operatively. Fifty-four (95%) of the 57 shoulders had no periprosthetic radiolucent lines at most recent follow-up. Complete post-operative glenoid seating was significantly associated with the absence of later periprosthetic radiolucency (p < 0.01).
CONCLUSION: This study reports low early radiolucency rates with the pegged, uncemented, metal-backed polyethylene glenoid prosthesis used. Excellent post-operative glenoid seating is associated with a significantly lower rate of radiolucency. Longer follow-up data are required to confirm these early promising results.Level of evidence: Therapeutic, level IV.
© 2018 The British Elbow & Shoulder Society.

Entities:  

Keywords:  arthroplasty; glenoid; lucency; metal backed; pegged; radiolucency; shoulder

Year:  2018        PMID: 33343711      PMCID: PMC7726176          DOI: 10.1177/1758573218789339

Source DB:  PubMed          Journal:  Shoulder Elbow        ISSN: 1758-5732


  53 in total

1.  Resurfacing of the glenoid in total shoulder arthroplasty. A comparison, at a mean of five years, of prostheses inserted with and without cement.

Authors:  A L Wallace; R L Phillips; G A MacDougal; W R Walsh; D H Sonnabend
Journal:  J Bone Joint Surg Am       Date:  1999-04       Impact factor: 5.284

2.  Incidence of early radiolucent glenoid lines in patients having total shoulder replacements.

Authors:  Steven Klepps; Alexis S Chiang; Suzanne Miller; Chun Yan Jiang; Yassamin Hazrati; Evan L Flatow
Journal:  Clin Orthop Relat Res       Date:  2005-06       Impact factor: 4.176

Review 3.  Failure of the glenoid component in anatomic total shoulder arthroplasty: a systematic review of the English-language literature between 2006 and 2012.

Authors:  Anastasios Papadonikolakis; Moni Blazej Neradilek; Frederick A Matsen
Journal:  J Bone Joint Surg Am       Date:  2013-12-18       Impact factor: 5.284

Review 4.  A comparison of pain, strength, range of motion, and functional outcomes after hemiarthroplasty and total shoulder arthroplasty in patients with osteoarthritis of the shoulder. A systematic review and meta-analysis.

Authors:  Dianne Bryant; Robert Litchfield; Michael Sandow; Gary M Gartsman; Gordon Guyatt; Alexandra Kirkley
Journal:  J Bone Joint Surg Am       Date:  2005-09       Impact factor: 5.284

5.  The results of arthroplasty in osteoarthritis of the shoulder.

Authors:  J F Haines; I A Trail; D Nuttall; A Birch; A Barrow
Journal:  J Bone Joint Surg Br       Date:  2006-04

6.  Total shoulder arthroplasty with the Neer prosthesis.

Authors:  R H Cofield
Journal:  J Bone Joint Surg Am       Date:  1984-07       Impact factor: 5.284

7.  The metal-backed glenoid component in rheumatoid disease: eight- to fourteen-year follow-up.

Authors:  Nicholas David Clement; Keshav Mathur; Robert Colling; Allan N Stirrat
Journal:  J Shoulder Elbow Surg       Date:  2010-03-02       Impact factor: 3.019

8.  Shoulder arthroplasty for rheumatoid arthritis: 303 consecutive cases with minimum 5-year follow-up.

Authors:  Jonathan D Barlow; Brandon J Yuan; Cathy D Schleck; W Scott Harmsen; Robert H Cofield; John W Sperling
Journal:  J Shoulder Elbow Surg       Date:  2013-12-04       Impact factor: 3.019

9.  Prosthetic arthroplasties of the shoulder.

Authors:  M L Clayton; D C Ferlic; P D Jeffers
Journal:  Clin Orthop Relat Res       Date:  1982-04       Impact factor: 4.176

10.  Clinical experience with total arthroplasty and hemiarthroplasty of the shoulder using the Neer prosthesis.

Authors:  S N Bell; N Gschwend
Journal:  Int Orthop       Date:  1986       Impact factor: 3.075

View more
  1 in total

1.  Medium-term rates of radiolucency after primary total shoulder arthroplasty using a cementless metal-backed pegged polyethylene glenoid.

Authors:  Nicholas J Murray; Khalid Al-Hourani; Mark Aa Crowther; Partha P Sarangi; Philip A McCann
Journal:  Shoulder Elbow       Date:  2020-03-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.