| Literature DB >> 20379676 |
Işil Sarikaya1, Ahmet Umut Güler.
Abstract
OBJECTIVE: The purpose of this study was to evaluate the effects of different polishing techniques on the surface roughness of dental porcelains.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20379676 PMCID: PMC5349026 DOI: 10.1590/s1678-77572010000100004
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Materials used in this study
| Feldspathic porcelain | VMK 95 | Vita Zahnfabrik, Germany |
| Feldspathic porcelain | Ceramco III | Degudent GmbH, USA |
| Low-fusing porcelain | Matchmaker MC | Schottlander, UK |
| Feldspathic porcelain blocks | Vitablocs Mark II | Vita Zahnfabrik, Germany |
| Finishing and polishing disc | Sof- Lex | 3M ESPE, USA |
| Porcelain polishing kit | NTI CeraGlaze | NTI- Kahla GmbH, Germany |
| Porcelain polishing kit | Dialite II | Brasseler, USA |
| Diamond polishing paste | Sparkle | Pulpdent, USA |
| Zirconium silicate cleaning- polishing prophy paste | Zircate | Dentsply Int. Inc., USA |
| Aluminum oxide polishing paste | Prisma Gloss | Dentsply Int. Inc., USA |
Polishing methods
| Group- C | Control (no surface treatment) |
| Group- Gl | Glaze |
| Group- Sl | Sof- Lex |
| Group- Pk | NTI CeraGlaze Polishing kit |
| Group- Di | Dialite II |
| Group- Sp | Sparkle |
| Group- Zr | Zircate |
| Group- Pg | Prisma Gloss |
| Group- SlSp | Sof- Lex+ Sparkle |
| Group- SlZr | Sof- Lex+ Zircate |
| Group- SlPg | Sof- Lex+ Prisma Gloss |
Two-way ANOVA for porcelain materials and different polishing techniques
| Polishing technique | 10 | 25.328 | 2.533 | 35.107 | .000 |
| Porcelain | 3 | 31.779 | 10.593 | 146.830 | .000 |
| Interaction | 30 | 17.431 | .581 | 8.054 | .000 |
| Error | 176 | 12.698 | .072 |
Significant difference at p<.05.
Mean (SD) of surface roughness and differences between groups for Vita VMK 95 porcelain
| C | 1.134 (0.64) | a,b |
| Gl | 0.724 (0.19) | a |
| Sl | 0.729 (0.17) | a |
| Pk | 0.640 (0.15) | a |
| Di | 0.700 (0.23) | a |
| Sp | 1.639 (0.26) | b,c |
| Zr | 2.241 (0.41) | c |
| Pg | 1.728 (0.47) | b,c |
| SlSp | 1.929 (0.76) | b,c |
| SlZr | 1.731 (0.48) | b,c |
| SlPg | 1.122 (0.24) | a,b |
Different letters indicate statistically significant difference between the groups (p<0.05).
Mean (SD) of surface roughness and differences between groups for Ceramco III porcelain
| C | 1.667 (0.21) | c,d |
| Gl | 0.609 (0.23) | a |
| Sl | 0.617 (0.10) | a |
| Pk | 0.639 (0.10) | a |
| Di | 0.999 (0.26) | a,b |
| Sp | 1.824 (0.39) | c,d |
| Zr | 1.974 (0.12) | d |
| Pg | 1.872 (0.18) | c,d |
| SlSp | 1.400 (0.19) | b,c |
| SlZr | 1.481 (0.22) | b,c |
| SlPg | 1.595 (0.29) | c,d |
Different letters indicate statistically significant difference between the groups (p<0.05).
Mean (SD) of surface roughness and differences between groups for Matchmaker MC porcelain
| C | 1.015 (0.23) | b,c,d |
| Gl | 0.456 (0.11) | a |
| Sl | 0.757 (0.11) | a,b,c |
| Pk | 0.691 (0.16) | a,b |
| Di | 0.366 (0.08) | a |
| Sp | 0.746 (0.26 | a,b,c |
| Zr | 1.728 (0.20) | f |
| Pg | 1.700 (0.10) | f |
| SISp | 1.262 (0.32) | d,e,f |
| SIZr | 1.652 (0.17) | e,f |
| SIPg | 1.175 (0.41) | c,d,e |
Different letters indicate statistically significant difference between the groups (p<0.05).
Mean (SD) of surface roughness and differences between groups for Mark II porcelain
| C | 0.314(0.12) | a |
| Gl | 0.406(0.18) | a,b |
| Sl | 0.431(0.09) | a,b |
| Pk | 0.584(0.04) | b |
| Di | 0.434(0.04) | a,b |
| Sp | 0.380(0.12) | a,b |
| Zr | 0.312(0.11) | a |
| Pg | 0.342(0.07) | a |
| SlSp | 0.386(0.06) | a,b |
| SlZr | 0.321(0.12) | a |
| SlPg | 0.364(0.13) | a,b |
Different letters indicate statistically significant difference between the groups (p<0.05).