PURPOSE: To measure the hemodynamic response to exercise using real-time velocity mapping magnetic resonance imaging (MRI), incorporating a high temporal resolution spiral phase contrast (PC) sequence accelerated with sensitivity encoding (SENSE). MATERIALS AND METHODS: Twenty healthy adults underwent MRI at rest and during supine exercise at two different exercise levels. Flow volumes were assessed in the ascending aorta using a spiral SENSE real-time PC sequence. The sequence was validated at rest against a vendor supplied gated PC sequence, and also at rest and during exercise against left ventricular volumes assessed using a radial k-t SENSE real-time sequence. Combining the measured flow volumes with simultaneous oscillometric blood pressure measurements, enabled the noninvasive calculations of systemic vascular resistance (SVR) and arterial compliance (C). RESULTS: Measured flow volumes correlated very well between the sequences at rest and during exercise. Cardiac output (CO) and heart rate were found to significantly increase during exercise, while SVR and C were found to decrease significantly. CONCLUSION: Hemodynamic response to exercise can be accurately quantified using a high temporal resolution spiral SENSE real-time flow imaging. This may allow early detection of hypertension and a greater understanding of the early changes in this condition. (c) 2010 Wiley-Liss, Inc.
PURPOSE: To measure the hemodynamic response to exercise using real-time velocity mapping magnetic resonance imaging (MRI), incorporating a high temporal resolution spiral phase contrast (PC) sequence accelerated with sensitivity encoding (SENSE). MATERIALS AND METHODS: Twenty healthy adults underwent MRI at rest and during supine exercise at two different exercise levels. Flow volumes were assessed in the ascending aorta using a spiral SENSE real-time PC sequence. The sequence was validated at rest against a vendor supplied gated PC sequence, and also at rest and during exercise against left ventricular volumes assessed using a radial k-t SENSE real-time sequence. Combining the measured flow volumes with simultaneous oscillometric blood pressure measurements, enabled the noninvasive calculations of systemic vascular resistance (SVR) and arterial compliance (C). RESULTS: Measured flow volumes correlated very well between the sequences at rest and during exercise. Cardiac output (CO) and heart rate were found to significantly increase during exercise, while SVR and C were found to decrease significantly. CONCLUSION: Hemodynamic response to exercise can be accurately quantified using a high temporal resolution spiral SENSE real-time flow imaging. This may allow early detection of hypertension and a greater understanding of the early changes in this condition. (c) 2010 Wiley-Liss, Inc.
Authors: Jan M Sohns; Johannes T Kowallick; Arun A Joseph; K Dietmar Merboldt; Dirk Voit; Martin Fasshauer; Wieland Staab; Jens Frahm; Joachim Lotz; Christina Unterberg-Buchwald Journal: Quant Imaging Med Surg Date: 2015-10
Authors: Guido E Pieles; Gergely Szantho; Jonathan C L Rodrigues; Christopher B Lawton; A Graham Stuart; Chiara Bucciarelli-Ducci; Mark S Turner; Craig A Williams; Robert M R Tulloh; Mark C K Hamilton Journal: Eur J Appl Physiol Date: 2014-02-07 Impact factor: 3.078
Authors: Adrienne E Campbell-Washburn; Mohammad A Tavallaei; Mihaela Pop; Elena K Grant; Henry Chubb; Kawal Rhode; Graham A Wright Journal: J Magn Reson Imaging Date: 2017-05-11 Impact factor: 4.813
Authors: Pei G Chew; Peter P Swoboda; Carrie Ferguson; Pankaj Garg; Abigail L Cook; Said Ibeggazene; Louise A E Brown; Thomas P Craven; James R Foley; Graham J Fent; Christopher E Saunderson; David M Higgins; Sven Plein; Karen M Birch; John P Greenwood Journal: Quant Imaging Med Surg Date: 2020-09
Authors: M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby Journal: Clin Radiol Date: 2016-03-02 Impact factor: 2.350
Authors: Laura Ellwein; Margaret M Samyn; Michael Danduran; Sheila Schindler-Ivens; Stacy Liebham; John F LaDisa Journal: Biomech Model Mechanobiol Date: 2016-07-04
Authors: Jennifer A Steeden; David Atkinson; Michael S Hansen; Andrew M Taylor; Vivek Muthurangu Journal: Radiology Date: 2011-03-17 Impact factor: 11.105
Authors: Kristian H Mortensen; Alexander Jones; Jennifer A Steeden; Andrew M Taylor; Vivek Muthurangu Journal: Eur Radiol Date: 2015-07-24 Impact factor: 5.315