Literature DB >> 28123969

Real-time magnetic resonance imaging of deep venous flow during muscular exercise-preliminary experience.

Arun Antony Joseph1, Klaus-Dietmar Merboldt2, Dirk Voit2, Johannes Dahm3, Jens Frahm1.   

Abstract

BACKGROUND: The accurate assessment of peripheral venous flow is important for the early diagnosis and treatment of disorders such as deep-vein thrombosis (DVT) which is a major cause of post-thrombotic syndrome or even death due to pulmonary embolism. The aim of this work is to quantitatively determine blood flow in deep veins during rest and muscular exercise using a novel real-time magnetic resonance imaging (MRI) method for velocity-encoded phase-contrast (PC) MRI at high spatiotemporal resolution.
METHODS: Real-time PC MRI of eight healthy volunteers and one patient was performed at 3 Tesla (Prisma fit, Siemens, Erlangen, Germany) using a flexible 16-channel receive coil (Variety, NORAS, Hoechberg, Germany). Acquisitions were based on a highly undersampled radial FLASH sequence with image reconstruction by regularized nonlinear inversion at 0.5×0.5×6 mm3 spatial resolution and 100 ms temporal resolution. Flow was assessed in two cross-sections of the lower leg at the level of the calf muscle and knee using a protocol of 10 s rest, 20 s flexion and extension of the foot, and 10 s rest. Quantitative analyses included through-plane flow in the right posterior tibial, right peroneal and popliteal vein (PC maps) as well as signal intensity changes due to flow and muscle movements (corresponding magnitude images).
RESULTS: Real-time PC MRI successfully monitored the dynamics of venous flow at high spatiotemporal resolution and clearly demonstrated increased flow in deep veins in response to flexion and extension of the foot. In normal subjects, the maximum velocity (averaged across vessel lumen) during exercise was 9.4±5.7 cm·s-1 for the right peroneal vein, 8.5±4.6 cm·s-1 for the right posterior tibial vein and 17.8±5.8 cm·s-1 for the popliteal vein. The integrated flow volume per exercise (20 s) was 1.9, 1.6 and 50 mL (mean across subjects) for right peroneal, right posterior tibial and popliteal vein, respectively. A patient with DVT presented with peak flow velocities of only about 2 cm·s-1 during exercise and less than 1 cm·s-1 during rest.
CONCLUSIONS: Real-time PC MRI emerges as a new tool for quantifying the dynamics of muscle-induced flow in deep veins. The method provides both signal intensity changes and velocity information for the assessment of blood flow and muscle movements. It now warrants extended clinical trials to patients with suspected thrombosis.

Entities:  

Keywords:  Deep venous flow; phase-contrast MRI; real-time MRI

Year:  2016        PMID: 28123969      PMCID: PMC5220202          DOI: 10.21037/cdt.2016.11.02

Source DB:  PubMed          Journal:  Cardiovasc Diagn Ther        ISSN: 2223-3652


  31 in total

Review 1.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH.

Authors:  Martin Uecker; Shuo Zhang; Jens Frahm
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

Review 3.  Phase contrast cine magnetic resonance imaging.

Authors:  N J Pelc; R J Herfkens; A Shimakawa; D R Enzmann
Journal:  Magn Reson Q       Date:  1991-10

4.  Image reconstruction by regularized nonlinear inversion--joint estimation of coil sensitivities and image content.

Authors:  Martin Uecker; Thorsten Hohage; Kai Tobias Block; Jens Frahm
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

5.  Real-time flow MRI of the aorta at a resolution of 40 msec.

Authors:  Arun Joseph; Johannes T Kowallick; Klaus-Dietmar Merboldt; Dirk Voit; Sebastian Schaetz; Shuo Zhang; Jan M Sohns; Joachim Lotz; Jens Frahm
Journal:  J Magn Reson Imaging       Date:  2013-10-11       Impact factor: 4.813

6.  Breathing affects venous return from legs in humans.

Authors:  R Willeput; C Rondeux; A De Troyer
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1984-10

7.  Direct cardiac NMR imaging of heart wall and blood flow velocity.

Authors:  P van Dijk
Journal:  J Comput Assist Tomogr       Date:  1984-06       Impact factor: 1.826

8.  Measurement of flow with NMR imaging using a gradient pulse and phase difference technique.

Authors:  D J Bryant; J A Payne; D N Firmin; D B Longmore
Journal:  J Comput Assist Tomogr       Date:  1984-08       Impact factor: 1.826

9.  Skeletal muscle pump versus respiratory muscle pump: modulation of venous return from the locomotor limb in humans.

Authors:  Jordan D Miller; David F Pegelow; Anthony J Jacques; Jerome A Dempsey
Journal:  J Physiol       Date:  2005-01-13       Impact factor: 5.182

10.  Diagnosis of Gastroesophageal Reflux Disease Using Real-time Magnetic Resonance Imaging.

Authors:  Shuo Zhang; Arun A Joseph; Lisa Gross; Michael Ghadimi; Jens Frahm; Alexander W Beham
Journal:  Sci Rep       Date:  2015-07-15       Impact factor: 4.379

View more
  2 in total

1.  Advanced venous imaging and image-guided venous interventions.

Authors:  Sasan Partovi; Suvranu Ganguli
Journal:  Cardiovasc Diagn Ther       Date:  2016-12

2.  Effects of periarticular injection on analgesic effects and NSAID use in total knee arthroplasty and total hip arthroplasty.

Authors:  Wen-Rui Ban; Ery-Ang Zhang; Lei-Feng Lv; Xiao-Qian Dang; Chen Zhang
Journal:  Clinics (Sao Paulo)       Date:  2017-12       Impact factor: 2.365

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.