Artifact-reduced two-dimensional cine steady state free precession for myocardial blood- oxygen-level-dependent imaging.

Xiangzhi Zhou1, Sotirios A Tsaftaris, Ying Liu, Richard Tang, Rachel Klein, Sven Zuehlsdorff, Debiao Li, Rohan Dharmakumar.   

Abstract

PURPOSE: To minimize image artifacts in long TR cardiac phase-resolved steady state free precession (SSFP) based blood-oxygen-level-dependent (BOLD) imaging.
MATERIALS AND METHODS: Nine healthy dogs (four male, five female, 20-25 kg) were studied in a clinical 1.5 Tesla MRI scanner to investigate the effect of temporal resolution, readout bandwidth, and motion compensation on long repetition time (TR) SSFP images. Breath-held 2D SSFP cine sequences with various temporal resolutions (10-204 ms), bandwidths (239-930 Hz/pixel), with and without first-order motion compensation were prescribed in the basal, mid-ventricular, and apical along the short axis. Preliminary myocardial BOLD studies in dogs with controllable coronary stenosis were performed to assess the benefits of artifact-reduction strategies.
RESULTS: Shortening the readout time by means of increasing readout bandwidth had no observable reduction in image artifacts. However, increasing the temporal resolution in the presence of first-order motion compensation led to significant reduction in image artifacts. Preliminary studies demonstrated that BOLD signal changes can be reliably detected throughout the cardiac cycle.
CONCLUSION: Artifact-reduction methods used in this study provide significant improvement in image quality compared with conventional long TR SSFP BOLD MRI. It is envisioned that the methods proposed here may enable reliable detection of myocardial oxygenation changes throughout the cardiac cycle with long TR SSFP-based myocardial BOLD MRI. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20373430      PMCID: PMC2919359          DOI: 10.1002/jmri.22116

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  16 in total

1.  Cine MR angiography of the heart with segmented true fast imaging with steady-state precession.

Authors:  J C Carr; O Simonetti; J Bundy; D Li; S Pereles; J P Finn
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

2.  Dark flow artifacts with steady-state free precession cine MR technique: causes and implications for cardiac MR imaging.

Authors:  Wei Li; Pippa Storey; Qun Chen; Belinda S Y Li; Pottumarthi V Prasad; Robert R Edelman
Journal:  Radiology       Date:  2004-02       Impact factor: 11.105

3.  Flow artifacts in steady-state free precession cine imaging.

Authors:  Pippa Storey; Wei Li; Qun Chen; Robert R Edelman
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

Review 4.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

5.  Flow effects in balanced steady state free precession imaging.

Authors:  M Markl; M T Alley; C J Elkins; N J Pelc
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

6.  Flow compensation in balanced SSFP sequences.

Authors:  O Bieri; K Scheffler
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

7.  Motion-insensitive, steady-state free precession imaging.

Authors:  Y Zur; M L Wood; L J Neuringer
Journal:  Magn Reson Med       Date:  1990-12       Impact factor: 4.668

8.  Ghost magnetic resonance angiography.

Authors:  Ioannis Koktzoglou; Robert R Edelman
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

9.  Oxygen-sensitive contrast in blood for steady-state free precession imaging.

Authors:  Rohan Dharmakumar; Juimiin Hong; Jean H Brittain; Donald B Plewes; Graham A Wright
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

10.  Pulsatile motion artifact reduction in 3D steady-state-free-precession-echo brain imaging.

Authors:  R D Tien; M Bernstein; J MacFall
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

View more
  7 in total

1.  Dictionary-Driven Ischemia Detection From Cardiac Phase-Resolved Myocardial BOLD MRI at Rest.

Authors:  Marco Bevilacqua; Rohan Dharmakumar; Sotirios A Tsaftaris
Journal:  IEEE Trans Med Imaging       Date:  2015-08-19       Impact factor: 10.048

2.  Assessment of myocardial oxygenation with MRI.

Authors:  Jie Zheng
Journal:  Quant Imaging Med Surg       Date:  2013-04

3.  Ischemic extent as a biomarker for characterizing severity of coronary artery stenosis with blood oxygen-sensitive MRI.

Authors:  Sotirios A Tsaftaris; Richard Tang; Xiangzhi Zhou; Debiao Li; Rohan Dharmakumar
Journal:  J Magn Reson Imaging       Date:  2012-01-13       Impact factor: 4.813

4.  Detecting myocardial ischemia at rest with cardiac phase-resolved blood oxygen level-dependent cardiovascular magnetic resonance.

Authors:  Sotirios A Tsaftaris; Xiangzhi Zhou; Richard Tang; Debiao Li; Rohan Dharmakumar
Journal:  Circ Cardiovasc Imaging       Date:  2012-12-18       Impact factor: 7.792

5.  Synthetic generation of myocardial blood-oxygen-level-dependent MRI time series via structural sparse decomposition modeling.

Authors:  Cristian Rusu; Rita Morisi; Davide Boschetto; Rohan Dharmakumar; Sotirios A Tsaftaris
Journal:  IEEE Trans Med Imaging       Date:  2014-03-21       Impact factor: 10.048

6.  Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging.

Authors:  Liheng Guo; Daniel A Herzka
Journal:  J Cardiovasc Magn Reson       Date:  2019-04-18       Impact factor: 5.364

Review 7.  Oxygenation-sensitive cardiovascular magnetic resonance.

Authors:  Matthias G Friedrich; Theodoros D Karamitsos
Journal:  J Cardiovasc Magn Reson       Date:  2013-05-24       Impact factor: 5.364