Literature DB >> 14705051

Flow artifacts in steady-state free precession cine imaging.

Pippa Storey1, Wei Li, Qun Chen, Robert R Edelman.   

Abstract

Steady-state free precession (SSFP) cardiac cine images are frequently corrupted by dark flow artifacts, which can usually be eliminated by reshimming and retuning the scanner. A theoretical explanation for these artifacts is provided in terms of spins moving through an off-resonant point in the magnetic field, and the theory is validated using phantom experiments. The artifacts can be reproduced in vivo by detuning the center frequency by an amount in the range of half the inverse repetition time (TR). Since this offset is similar in magnitude to the frequency difference between the water and lipid peaks, a likely cause of the artifacts in vivo is that the center frequency is tuned incorrectly to the lipid peak rather than the water peak. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 14705051     DOI: 10.1002/mrm.10665

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies.

Authors:  E V R Di Bella; D L Parker; A J Sinusas
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

Review 2.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

3.  Noncontrast dynamic 3D intracranial MR angiography using pseudo-continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; David J Rusinak; Yijing Wu; Kevin M Johnson
Journal:  J Magn Reson Imaging       Date:  2013-10-15       Impact factor: 4.813

4.  Mitigation of near-band balanced steady-state free precession through-plane flow artifacts using partial dephasing.

Authors:  Anjali Datta; Joseph Y Cheng; Brian A Hargreaves; Corey A Baron; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2017-10-10       Impact factor: 4.668

Review 5.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

6.  Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging.

Authors:  Jaime S Robb; Chenxi Hu; Dana C Peters
Journal:  Magn Reson Med       Date:  2019-10-12       Impact factor: 4.668

7.  Artifact-reduced two-dimensional cine steady state free precession for myocardial blood- oxygen-level-dependent imaging.

Authors:  Xiangzhi Zhou; Sotirios A Tsaftaris; Ying Liu; Richard Tang; Rachel Klein; Sven Zuehlsdorff; Debiao Li; Rohan Dharmakumar
Journal:  J Magn Reson Imaging       Date:  2010-04       Impact factor: 4.813

8.  Vortex Flow in the Right Atrium Surrogates Supraventricular Arrhythmia and Thrombus After Atriopulmonary Connection-Type Fontan Operation: Vortex Flow Analysis Using Conventional Cine Magnetic Resonance Imaging.

Authors:  Yumi Shiina; Kei Inai; Tatsunori Takahashi; Yamato Shimomiya; Umiko Ishizaki; Kenji Fukushima; Michinobu Nagao
Journal:  Pediatr Cardiol       Date:  2017-11-02       Impact factor: 1.655

9.  Radial fast interrupted steady-state (FISS) magnetic resonance imaging.

Authors:  Ioannis Koktzoglou; Robert R Edelman
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

10.  Acquisition of the pulmonary venous and left atrial anatomy with non-contrast-enhanced MRI for catheter ablation of atrial fibrillation: Usefulness of two-dimensional balanced steady-state free precession.

Authors:  Yutaka Shigenaga; Kunihiko Kiuchi; Katsunori Okajima; Kazushi Ikeuchi; Takayuki Ikeda; Akira Shimane; Kiminobu Yokoi; Jin Teranishi; Kousuke Aoki; Misato Chimura; Hideyuki Masai; Shinichiro Yamada; Yasuyo Taniguchi; Yoshinori Yasaka; Hiroya Kawai
Journal:  J Arrhythm       Date:  2014-12-23
View more