Literature DB >> 14586999

Flow effects in balanced steady state free precession imaging.

M Markl1, M T Alley, C J Elkins, N J Pelc.   

Abstract

An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady-state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various through-plane flow waveforms and rates were modeled numerically considering factors such as the excitation slice profile and both in- and out-flow effects. Phantom measurements in an experimental setup that allowed the assessment of SSFP signal properties as a function of frequency offset and flow rate demonstrated that the computer simulations provided a suitable description of the effects of flow in SSFP imaging. A volunteer scan was performed to provide in vivo validations. For accurate modeling of SSFP signal intensities it is crucial to include effects such as imperfect slice profiles and, more importantly, "out-of-slice" contributions to the signal. Both simulations and experiments show that there can be considerably large-frequency offset dependent-signal contributions from flowing spins that have already left the imaging slice but still add to the SSFP signal. Although spins leaving the slice do not experience additional RF-excitation, gradient activity is not confined to the region of excitations and the balanced nature of the SSFP imaging gradients allows "out-of-slice" transverse magnetization to contribute to the total SSFP signal, effectively by broadening the slice thickness for flowing spins. This results in a frequency dependence of in-flow related signal enhancement and flow artifacts. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 14586999     DOI: 10.1002/mrm.10631

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  42 in total

Review 1.  Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside.

Authors:  Pierre Croisille; Didier Revel; Maythem Saeed
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  Quantification of arterial cerebral blood volume using multiphase-balanced SSFP-based ASL.

Authors:  Lirong Yan; Cheng Li; Emily Kilroy; Felix W Wehrli; Danny J J Wang
Journal:  Magn Reson Med       Date:  2011-11-29       Impact factor: 4.668

3.  Evaluation of lumber nerve root compression using thin-slice thickness coronal magnetic resonance imaging: three-dimensional fat-suppressed multi-shot balanced non-steady-state free precession versus three-dimensional T1-weighted spoiled gradient-recalled echo.

Authors:  Keizo Tanitame; Nobuko Tanitame; Chihiro Tani; Masaki Ishikawa; Miyuki Takasu; Shuji Date; Keiko Otani; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

4.  Brain MR perfusion-weighted imaging with alternate ascending/descending directional navigation.

Authors:  Sung-Hong Park; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2010-09-21       Impact factor: 4.668

5.  Comparison of wideband steady-state free precession and T₂-weighted fast spin echo in spine disorder assessment at 1.5 and 3 T.

Authors:  Giovanna S Danagoulian; Lei Qin; Krishna S Nayak; Rivka R Colen; Srinivasan Mukundan; Mitchell B Harris; Ferenc A Jolesz; Ajit Shankaranarayanan; William A Copen; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2012-01-27       Impact factor: 4.668

6.  Noncontrast SSFP pulmonary vein magnetic resonance angiography: impact of off-resonance and flow.

Authors:  Peng Hu; Christian T Stoeck; Jouke Smink; Dana C Peters; Long Ngo; Beth Goddu; Kraig V Kissinger; Lois A Goepfert; Jonathan Chan; Thomas H Hauser; Neil M Rofsky; Warren J Manning; Reza Nezafat
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

7.  On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies.

Authors:  E V R Di Bella; D L Parker; A J Sinusas
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

8.  Improving contrast to noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession.

Authors:  Jongho Lee; Masaki Fukunaga; Jeff H Duyn
Journal:  Neuroimage       Date:  2010-10-30       Impact factor: 6.556

9.  Noncontrast dynamic 3D intracranial MR angiography using pseudo-continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; David J Rusinak; Yijing Wu; Kevin M Johnson
Journal:  J Magn Reson Imaging       Date:  2013-10-15       Impact factor: 4.813

10.  Multiple repetition time balanced steady-state free precession imaging.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.