Literature DB >> 11376278

Cine MR angiography of the heart with segmented true fast imaging with steady-state precession.

J C Carr1, O Simonetti, J Bundy, D Li, S Pereles, J P Finn.   

Abstract

In five healthy subjects and 18 patients, cine magnetic resonance (MR) imaging of the heart was performed with a true fast imaging with steady-state precession (FISP) sequence. Results were compared both quantitatively and qualitatively with those at cine fast low-angle shot (FLASH) MR imaging. The blood-myocardial contrast-to-noise ratio (CNR) was 2.0 times higher and the normalized (for measurement time and pixel size) blood-myocardial CNR was 4.0 times higher for true FISP compared with FLASH MR imaging. Qualitative scores for image quality were significantly higher with true FISP MR imaging. Segmented cine true FISP MR imaging generated high-contrast MR images of the heart in healthy subjects and in patients with heart disease and produced image quality superior to that with cine FLASH MR imaging.

Entities:  

Mesh:

Year:  2001        PMID: 11376278     DOI: 10.1148/radiology.219.3.r01jn44828

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  99 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging.

Authors:  Peter Hunold; Stefan Maderwald; Holger Eggebrecht; Florian M Vogt; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2003-11-26       Impact factor: 5.315

3.  High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession.

Authors:  Dana C Peters; Daniel B Ennis; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

4.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

Review 5.  Cardiac MRI for clinicians: an overview.

Authors:  A J Duerinckx
Journal:  Int J Cardiovasc Imaging       Date:  2001-12       Impact factor: 2.357

6.  Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques.

Authors:  C Kupfahl; M Honold; G Meinhardt; H Vogelsberg; A Wagner; H Mahrholdt; U Sechtem
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

7.  Signal-to-noise ratio behavior of steady-state free precession.

Authors:  Scott B Reeder; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

8.  Unenhanced dynamic MR angiography: high spatial and temporal resolution by using true FISP-based spin tagging with alternating radiofrequency.

Authors:  Lirong Yan; Sumei Wang; Yan Zhuo; Ronald L Wolf; Michael F Stiefel; Jing An; Yongquan Ye; Qian Zhang; Elias R Melhem; Danny J J Wang
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

9.  Self-gated fat-suppressed cardiac cine MRI.

Authors:  R Reeve Ingle; Juan M Santos; William R Overall; Michael V McConnell; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-05-07       Impact factor: 4.668

10.  An approach to the three-dimensional display of left ventricular function and viability using MRI.

Authors:  Cory Swingen; Ravi Teja Seethamraju; Michael Jerosch-Herold
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.