Intra- and inter-reader reproducibility of blood flow measurements on the ascending aorta and pulmonary artery using cardiac magnetic resonance.

Giovanni Di Leo1, Ida Daniela D'Angelo2, Marco Alì3, Paola Maria Cannaò1, Giovanni Mauri1, Francesco Secchi1, Francesco Sardanelli1,4.   

Abstract

The aim of our study was to estimate the intra- and inter-reader reproducibility of blood flow measurements in the ascending aorta and main pulmonary artery using cardiac magnetic resonance (CMR) and a semi-automated segmentation method. The ethics committee approved this retrospective study. A total of 50 consecutive patients (35 males and 15 females; mean age±standard deviation 27±13 years) affected by congenital heart disease were reviewed. They underwent CMR for flow analysis of the ascending aorta and main pulmonary artery (1.5 T, through-plane phase-contrast sequences). Two independent readers (R1, trained radiology resident; R2, lower-trained technician student) obtained segmented images twice (>10-day interval), using a semi-automated method of segmentation. Peak velocity, forward and backward flows were obtained. Bland-Altman analysis was used and reproducibility was reported as complement to 100% of the ratio between the coefficient of repeatability and the mean. R1 intra-reader reproducibility for the aorta was 99% (peak velocity), 95% (forward flow) and 49% (backward flow); for the pulmonary artery, 99%, 91% and 90%, respectively. R2 intra-reader reproducibility was 92%, 91% and 38%; 98%, 86% and 87%, respectively. Inter-reader reproducibility for the aorta was 91%, 85% and 20%; for the pulmonary artery 96%, 75%, and 82%, respectively. Our results showed a good to excellent reproducibility of blood flow measurements of CMR together with a semiautomated method of segmentation, for all variables except the backward flow of the ascending aorta, with a limited impact of operator's training.

Entities:  

Keywords:  Blood flow; Cardiac magnetic resonance; Heart valve; Phase-contrast sequences; Reproducibility

Mesh:

Year:  2016        PMID: 27878504     DOI: 10.1007/s11547-016-0706-6

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  19 in total

1.  Visualization of through-plane blood flow measurements obtained from phase-contrast MRI.

Authors:  Per Thunberg; Anders Kähäri
Journal:  J Digit Imaging       Date:  2011-06       Impact factor: 4.056

Review 2.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

3.  ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons.

Authors:  Robert O Bonow; Blase A Carabello; Kanu Chatterjee; Antonio C de Leon; David P Faxon; Michael D Freed; William H Gaasch; Bruce Whitney Lytle; Rick A Nishimura; Patrick T O'Gara; Robert A O'Rourke; Catherine M Otto; Pravin M Shah; Jack S Shanewise; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Elliott M Antman; Valentin Fuster; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Bruce W Lytle; Rick Nishimura; Richard L Page; Barbara Riegel
Journal:  J Am Coll Cardiol       Date:  2006-08-01       Impact factor: 24.094

Review 4.  Cardiovascular magnetic resonance imaging for valvular heart disease: technique and validation.

Authors:  Peter J Cawley; Jeffrey H Maki; Catherine M Otto
Journal:  Circulation       Date:  2009-01-27       Impact factor: 29.690

5.  Measurements in radiology: the need for high reproducibility.

Authors:  Giovanni Di Leo
Journal:  Pediatr Radiol       Date:  2015-01-01

6.  Four-year cardiac magnetic resonance (CMR) follow-up of patients treated with percutaneous pulmonary valve stent implantation.

Authors:  Francesco Secchi; Elda Chiara Resta; Paola Maria Cannaò; Silvia Tresoldi; Gianfranco Butera; Mario Carminati; Francesco Sardanelli
Journal:  Eur Radiol       Date:  2015-05-21       Impact factor: 5.315

Review 7.  MR imaging of aortic coarctation.

Authors:  F Secchi; A Iozzelli; G D E Papini; A Aliprandi; G Di Leo; F Sardanelli
Journal:  Radiol Med       Date:  2009-05-14       Impact factor: 3.469

8.  Automated vessel edge detection in velocity-encoded cine-MR (VEC-MR) flow measurements: a retrospective evaluation in critically ill patients.

Authors:  Christine B Henk; Stephan Grampp; Werner Backfrieder; Jasmin Liskutin; Christian Czerny; Gerhard H Mostbeck
Journal:  Eur J Radiol       Date:  2003-12       Impact factor: 3.528

Review 9.  The role of cardiac magnetic resonance in valvular heart disease.

Authors:  Juan C Lopez-Mattei; Dipan J Shah
Journal:  Methodist Debakey Cardiovasc J       Date:  2013 Jul-Sep

10.  Changes in aortic distensibility and pulse wave velocity assessed with magnetic resonance imaging following beta-blocker therapy in the Marfan syndrome.

Authors:  M Groenink; A de Roos; B J Mulder; J A Spaan; E E van der Wall
Journal:  Am J Cardiol       Date:  1998-07-15       Impact factor: 2.778

View more
  3 in total

1.  Blood-threshold CMR volume analysis of functional univentricular heart.

Authors:  Francesco Secchi; Marco Alì; Marcello Petrini; Francesca Romana Pluchinotta; Andrea Cozzi; Mario Carminati; Francesco Sardanelli
Journal:  Radiol Med       Date:  2018-01-22       Impact factor: 3.469

2.  Measurement of jugular foramen diameter using MRI in multiple sclerosis patients compared to control subjects.

Authors:  Giacomo Davide Edoardo Papini; Giovanni Di Leo; Moreno Zanardo; Maria Paola Fedeli; Ilaria Merli; Francesco Sardanelli
Journal:  Eur Radiol Exp       Date:  2017-06-29

3.  Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance.

Authors:  Jannike Nickander; Magnus Lundin; Goran Abdula; Jonas Jenner; Eva Maret; Peder Sörensson; Einar Heiberg; Andreas Sigfridsson; Martin Ugander
Journal:  Sci Rep       Date:  2020-03-19       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.