Literature DB >> 18243947

Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods.

B D Smith.   

Abstract

Previously unknown sufficient conditions, a necessary condition, and reconstruction methods for image reconstruction from cone-beam projections are developed. A sufficient condition developed is contained in the following statement. Statement 5: If one every plane that intersects the object, there exists at least one cone-beam source point, then the object can be reconstructed. Reconstruction methods for an arbitrary configuration of source points that satisfy Statement 5 are derived. By requiring additional conditions on the configuration of source points, a more efficient reconstruction method is developed. It is shown that when the configuration of source points is a circle, Statement 5 is not satisfied. In spite of this, several suggestions are made for reconstruction from a circle of source points.

Year:  1985        PMID: 18243947     DOI: 10.1109/TMI.1985.4307689

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  Dedicated breast CT: radiation dose for circle-plus-line trajectory.

Authors:  Srinivasan Vedantham; Linxi Shi; Andrew Karellas; Frederic Noo
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

Review 3.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

4.  Properties of the prototype 256-row (cone beam) CT scanner.

Authors:  Shinichiro Mori; Masahiro Endo; Takayuki Obata; Takanori Tsunoo; Kandatsu Susumu; Shuji Tanada
Journal:  Eur Radiol       Date:  2006-03-28       Impact factor: 5.315

5.  A local shift-variant Fourier model and experimental validation of circular cone-beam computed tomography artifacts.

Authors:  Steven Bartolac; Roll Clackdoyle; Frederic Noo; Jeff Siewerdsen; Douglas Moseley; David Jaffray
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

6.  Analytic Derivation and Monte Carlo Validation of a Sensitivity Formula for Slit-Slit Collimation With Penetration.

Authors:  Ahmet S Ayan; Scott D Metzler; Roberto Accorsi
Journal:  IEEE Trans Nucl Sci       Date:  2010-02-08       Impact factor: 1.679

7.  Brain SPECT Simulation Using Half-Cone-Beam Collimation and Single-Revolution Helical-Path Acquisition.

Authors:  Ruben Ter-Antonyan; Ronald J Jaszczak; James E Bowsher; Kim L Greer; Scott D Metzler
Journal:  IEEE Trans Nucl Sci       Date:  2007       Impact factor: 1.679

8.  Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph.

Authors:  P Madhav; D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

9.  FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT.

Authors:  A V Narasimhadhan; Kasi Rajgopal
Journal:  Int J Biomed Imaging       Date:  2012-02-16

10.  Cone beam micro-CT system for small animal imaging and performance evaluation.

Authors:  Shouping Zhu; Jie Tian; Guorui Yan; Chenghu Qin; Jinchao Feng
Journal:  Int J Biomed Imaging       Date:  2009-09-22
View more