Literature DB >> 20339253

Radiation dose and radiation protection for patients and physicians during interventional procedure.

Koichi Chida1, Mamoru Kato, Yutaka Kagaya, Masayuki Zuguchi, Haruo Saito, Tadashi Ishibashi, Shoki Takahashi, Shogo Yamada, Yoshihiro Takai.   

Abstract

Although the wide acceptance of interventional radiology (IVR) procedures has led to increasing numbers of interventions being performed, the radiation doses from IVR are higher. Increasing numbers of case reports of patient radiation injury resulting from IVR are being published. Therefore, radiation protection during IVR poses a very important problem. To protect against radiation injury, the evaluation of radiation dose is essential. The radiation dose must be evaluated for each IVR x-ray machine and each laboratory, because it varies greatly. To obtain this information easily, and to ensure practical use of the radiation information, good relationships between interventionists and medical physicists are essential.

Entities:  

Mesh:

Year:  2010        PMID: 20339253     DOI: 10.1269/jrr.09112

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  16 in total

1.  Comparison of dose at an interventional reference point between the displayed estimated value and measured value.

Authors:  Koichi Chida; Yohei Inaba; Yoshiaki Morishima; Masaaki Taura; Ayako Ebata; Isao Yanagawa; Ken Takeda; Masayuki Zuguchi
Journal:  Radiol Phys Technol       Date:  2011-06-04

2.  The effectiveness of additional lead-shielding drape and low pulse rate fluoroscopy in protecting staff from scatter radiation during cardiac resynchronization therapy (CRT).

Authors:  Yoshiaki Morishima; Koichi Chida; Yoshiaki Katahira
Journal:  Jpn J Radiol       Date:  2018-10-15       Impact factor: 2.374

3.  Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom.

Authors:  Yoshiaki Morishima; Koichi Chida; Yoshikazu Muroya; Yoshiya Utsumi
Journal:  Dysphagia       Date:  2017-09-18       Impact factor: 3.438

4.  Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians.

Authors:  Mime Endo; Yoshihiro Haga; Masahiro Sota; Akiko Tanaka; Kazuki Otomo; Yuuki Murabayashi; Mitsuya Abe; Yuji Kaga; Yohei Inaba; Msatoshi Suzuki; Taiichiro Meguro; Koichi Chida
Journal:  J Radiat Res       Date:  2021-05-12       Impact factor: 2.724

5.  Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures.

Authors:  Hiroki Ishii; Koichi Chida; Ko Satsurai; Yoshihiro Haga; Yuji Kaga; Mitsuya Abe; Yohei Inaba; Masayuki Zuguchi
Journal:  Radiol Phys Technol       Date:  2022-01-23

6.  Management of fluoroscopy-induced radiation ulcer: One-stage radical excision and immediate reconstruction.

Authors:  Kai-Che Wei; Kuo-Chung Yang; Lee-Wei Chen; Wen-Chung Liu; Wen-Chieh Chen; Wen-Yen Chiou; Ping-Chin Lai
Journal:  Sci Rep       Date:  2016-10-21       Impact factor: 4.379

7.  Occupational eye dose in interventional cardiology procedures.

Authors:  Yoshihiro Haga; Koichi Chida; Yuji Kaga; Masahiro Sota; Taiichiro Meguro; Masayuki Zuguchi
Journal:  Sci Rep       Date:  2017-04-03       Impact factor: 4.379

8.  Effectiveness of additional lead shielding to protect staff from scattering radiation during endoscopic retrograde cholangiopancreatography procedures.

Authors:  Yoshiaki Morishima; Koichi Chida; Takayoshi Meguro
Journal:  J Radiat Res       Date:  2018-03-01       Impact factor: 2.724

9.  Personal Protective Equipment Availability and Utilization Among Interventionalists.

Authors:  André Rose; William Ian Duncombe Rae
Journal:  Saf Health Work       Date:  2018-10-10

10.  Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization.

Authors:  Lue Sun; Yusuke Mizuno; Mari Iwamoto; Takahisa Goto; Yasuhiro Koguchi; Yuka Miyamoto; Koji Tsuboi; Koichi Chida; Takashi Moritake
Journal:  J Radiat Res       Date:  2014-06-26       Impact factor: 2.724

View more