Literature DB >> 20305334

Out-of-field photon dose following removal of the flattening filter from a medical accelerator.

Stephen F Kry1, Oleg N Vassiliev, Radhe Mohan.   

Abstract

The aim of this paper is to determine the effect of removing the flattening filter from a linear accelerator on the out-of-field photon dose. A Monte Carlo model was used to simulate 6 MV and 18 MV photon beams from a Varian 2100 accelerator with the flattening filter in place and with it removed. The out-of-field photon doses and composition (head leakage, patient scatter and collimator scatter) were calculated from square open fields in a water tank as a function of distance from central axis, field size and depth. The out-of-field doses resulting from intensity-modulated radiation therapy to the prostate at 6 MV were also calculated, with and without the flattening filter, to sensitive organs in an anthropomorphic Rando phantom. Removal of the flattening filter reduced the out-of-field dose near the treatment field (<3 cm from the field edge) because of decreased collimator scatter. It increased the out-of-field dose at intermediate distances from the field edge (3-15 cm) because of increased patient scatter. At greater distances, the out-of-field dose was decreased because of reduced head leakage. For the clinical treatment examined, the out-of-field dose was generally reduced following removal of the flattening filter, particularly at large distances from the treatment field. Removal of the flattening filter may be advantageous by reducing the out-of-field dose to the patient. This could contribute to reducing the long-term risk of secondary malignancies. In general, however, the out-of-field dose depends on treatment and patient parameters, and a reduction may not always be achievable.

Entities:  

Mesh:

Year:  2010        PMID: 20305334     DOI: 10.1088/0031-9155/55/8/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Risk of second malignant neoplasm following proton versus intensity-modulated photon radiotherapies for hepatocellular carcinoma.

Authors:  Phillip J Taddei; Rebecca M Howell; Sunil Krishnan; Sarah B Scarboro; Dragan Mirkovic; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

2.  Comparison of surface dose delivered by 7 MV-unflattened and 6 MV-flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

3.  Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR).

Authors:  Taeho Kim; Lei Zhu; Tae-Suk Suh; Sarah Geneser; Bowen Meng; Lei Xing
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  Technical Report: Evaluation of peripheral dose for flattening filter free photon beams.

Authors:  E L Covington; T A Ritter; J M Moran; A M Owrangi; J I Prisciandaro
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

5.  Analytical model for out-of-field dose in photon craniospinal irradiation.

Authors:  Phillip J Taddei; Wassim Jalbout; Rebecca M Howell; Nabil Khater; Fady Geara; Kenneth Homann; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2013-10-08       Impact factor: 3.609

Review 6.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

7.  Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Peripheral Lung Cancer with Flattening Filter Free Beams.

Authors:  Bao-Tian Huang; Jia-Yang Lu; Pei-Xian Lin; Jian-Zhou Chen; Yu Kuang; Chuang-Zhen Chen
Journal:  PLoS One       Date:  2015-07-01       Impact factor: 3.240

8.  Surface dose measurements and comparison of unflattened and flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj; Girigesh Yadav; Ananda Giribabu; Karthikeyan Srinivasan; Venkadamanickam Gurusamy; Kothanda Raman; Kaviarasu Karunakaran; Rajesh Thiyagarajan
Journal:  J Med Phys       Date:  2016 Apr-Jun

9.  Dosimetric differences in flattened and flattening filter-free beam treatment plans.

Authors:  Yue Yan; Poonam Yadav; Michael Bassetti; Kaifang Du; Daniel Saenz; Paul Harari; Bhudatt R Paliwal
Journal:  J Med Phys       Date:  2016 Apr-Jun

10.  Out-of-field dose in stereotactic radiotherapy for paediatric patients.

Authors:  Lachlan Garrett; Nicholas Hardcastle; Adam Yeo; Peta Lonski; Rick Franich; Tomas Kron
Journal:  Phys Imaging Radiat Oncol       Date:  2021-06-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.