Literature DB >> 2026634

Joint moment and muscle power output characteristics of below knee amputees during running: the influence of energy storing prosthetic feet.

J M Czerniecki1, A Gitter, C Munro.   

Abstract

Stance phase joint moments, muscle power outputs and mechanical energy characteristics were determined in five normal and five below knee amputee subjects running at 2.8 m s-1. The amputees were studied sequentially on three different prosthetic feet: the SACH foot (solid ankle cushion heel), and two energy storing feet, Seattle and Flex. While wearing the SACH foot, the amputees exhibited major alterations in the distribution and magnitude of muscle power output and muscle work: (1) the total work done by the lower extremity was reduced; (2) the hip extensors became the main source of energy absorption and generation, while in normal subjects the ankle plantarflexors were the major energy generators and the knee extensors the major energy absorbers; (3) the eccentric and concentric knee extensor power outputs were reduced and an abnormal concentric knee flexor power output was noted immediately after heel contact. In four of the amputees, energy storing feet resulted in improvements in the power output and mechanical work characteristics of the lower extremity: (1) the energy storing prosthetic feet generated 2-3 times greater energy than the SACH foot; (2) with the Flex foot the amputees exhibited a more normal pattern and magnitude of hip and knee extensor muscle work. One of the subjects, however, exhibited increased abnormalities with the energy storing prosthetic feet. The amount of energy restored relative to the amount of energy absorbed by each of the prosthetic feet was greater with the energy storing feet than the SACH foot (Flex 84%, Seattle 52%, SACH 31%).

Mesh:

Year:  1991        PMID: 2026634     DOI: 10.1016/0021-9290(91)90327-j

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

1.  Biomechanical evaluation of a prototype foot/ankle prosthesis.

Authors:  P M Quesada; M Pitkin; J Colvin
Journal:  IEEE Trans Rehabil Eng       Date:  2000-03

2.  Systematic methodology for the design of a flexible keel for energy-storing prosthetic feet.

Authors:  T S Jang; J J Lee; D H Lee; Y S Yoon
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

3.  Amputee Locomotion: Joint Moment Adaptations to Running Speed Using Running-Specific Prostheses after Unilateral Transtibial Amputation.

Authors:  Brian S Baum; Hiroaki Hobara; Kyung Koh; Hyun Joon Kwon; Ross H Miller; Jae Kun Shim
Journal:  Am J Phys Med Rehabil       Date:  2019-03       Impact factor: 2.159

Review 4.  Amputees and sports: a systematic review.

Authors:  Mihail Bragaru; Rienk Dekker; Jan H B Geertzen; Pieter U Dijkstra
Journal:  Sports Med       Date:  2011-09-01       Impact factor: 11.136

5.  How do prosthetic stiffness, height and running speed affect the biomechanics of athletes with bilateral transtibial amputations?

Authors:  Owen N Beck; Paolo Taboga; Alena M Grabowski
Journal:  J R Soc Interface       Date:  2017-06       Impact factor: 4.118

6.  Using computational and mechanical models to study animal locomotion.

Authors:  Laura A Miller; Daniel I Goldman; Tyson L Hedrick; Eric D Tytell; Z Jane Wang; Jeannette Yen; Silas Alben
Journal:  Integr Comp Biol       Date:  2012-09-16       Impact factor: 3.326

7.  Criterion and construct validity of prosthesis-integrated measurement of joint moment data in persons with transtibial amputation.

Authors:  Goeran Fiedler; Brooke Slavens; Roger O Smith; Douglas Briggs; Brian J Hafner
Journal:  J Appl Biomech       Date:  2014-03-04       Impact factor: 1.833

8.  Systematic variation of prosthetic foot spring affects center-of-mass mechanics and metabolic cost during walking.

Authors:  Karl E Zelik; Steven H Collins; Peter G Adamczyk; Ava D Segal; Glenn K Klute; David C Morgenroth; Michael E Hahn; Michael S Orendurff; Joseph M Czerniecki; Arthur D Kuo
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2011-06-23       Impact factor: 3.802

9.  Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

Authors:  Toshiki Kobayashi; Adam K Arabian; Michael S Orendurff; Teri G Rosenbaum-Chou; David A Boone
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-11-13       Impact factor: 2.063

10.  The Effects of Prosthesis Inertial Parameters on Inverse Dynamics: A Probabilistic Analysis.

Authors:  Brecca M M Gaffney; Cory L Christiansen; Amanda M Murray; Casey A Myers; Peter J Laz; Bradley S Davidson
Journal:  J Verif Valid Uncertain Quantif       Date:  2017-10-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.