Potential errors in pulse oximetry. III: Effects of interferences, dyes, dyshaemoglobins and other pigments.

A C Ralston1, R K Webb, W B Runciman.   

Abstract

Electrosurgery, patient motion and some types of lighting can cause errors in saturation readout; it is recommended that probes should be shielded from ambient lighting. Intravenous dyes can introduce gross but transient errors, which may also be present in in vitro measurements. Carboxyhaemoglobin causes overestimation of fractional saturation by an amount less than, but possibly close to, the percent of carboxyhaemoglobin present. Methaemoglobin causes the pulse oximeter readout to tend towards 85%. Fetal haemoglobin and bilirubin introduce no significant error, although they may interfere with in vitro measurements. Skin pigmentation can result in a slight decrease in accuracy. Nail polish may cause up to 6% underestimation of saturation; it is recommended that probes should be mounted sideways on fingers with nail polish or long nails. Adhesive tape or a vinyl glove across the probe has no demonstrable effect on accuracy. A blood sample should be analysed by a multiwavelength in vitro oximeter when an erroneous pulse oximeter reading is suspected, although errors may be introduced in the in vitro reading by fetal haemoglobin, bilirubin and intravenous dyes.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2024749     DOI: 10.1111/j.1365-2044.1991.tb11501.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  26 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

Review 2.  Pulse oximetry in supportive and palliative care.

Authors:  Vandana A Vora; Sam H Ahmedzai
Journal:  Support Care Cancer       Date:  2004-11       Impact factor: 3.603

3.  Dyed but not dead.

Authors:  Shireen H Haque; Bobby D Nossaman
Journal:  Ochsner J       Date:  2012

Review 4.  Pulse oximetry: a practical review.

Authors:  C D Hanning; J M Alexander-Williams
Journal:  BMJ       Date:  1995-08-05

5.  Monitoring during endoscopy. Pulse oximetry has limitations.

Authors:  M Stoneham
Journal:  BMJ       Date:  1995-08-12

6.  A new system to record reliable pulse oximetry data from the Nellcor N-200 and its applications in studies of variability in infant oxygenation.

Authors:  D Sprague; M S Richardson; J W Baish; J S Kemp
Journal:  J Clin Monit       Date:  1996-01

Review 7.  Continuous intra-arterial blood gas monitoring.

Authors:  B Venkatesh; S P Hendry
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

8.  The effects of gel-based manicure on pulse oximetry.

Authors:  Jia Lin Jacklyn Yek; Hairil Rizal Abdullah; June Pheck Suan Goh; Yew Weng Chan
Journal:  Singapore Med J       Date:  2019-03-11       Impact factor: 1.858

9.  Pulse oximetry in an extensively burned patient.

Authors:  H Imaizumi; Y Ujike; S Sumita; M Kaneko
Journal:  J Clin Monit       Date:  1995-01

10.  The benefits and pitfalls of pulse oximetry.

Authors:  P Hutton; T Clutton-Brock
Journal:  BMJ       Date:  1993-08-21