Literature DB >> 22778677

Dyed but not dead.

Shireen H Haque1, Bobby D Nossaman.   

Abstract

The use of vital blue dyes in sentinel lymph node mapping and biopsy is gaining popularity in the surgical management of cancer. However, intraoperative use of these dyes has associated risks for the patient. This case report and review of the literature present current medical knowledge about one of the vital blue dyes, isosulfan blue, and the associated clinical risks of this dye when used in the perioperative management of patients who undergo sentinel lymph node mapping and biopsy.

Entities:  

Keywords:  Anaphylaxis; cancer; isosulfan blue; methemoglobinemia; pulse oximetry; vital dyes

Year:  2012        PMID: 22778677      PMCID: PMC3387838     

Source DB:  PubMed          Journal:  Ochsner J        ISSN: 1524-5012


  51 in total

1.  Use of isosulfan blue in breast surgery interferes with pulse oximetry.

Authors:  N A Wisely; Z Zeiton
Journal:  Anaesthesia       Date:  2005-06       Impact factor: 6.955

2.  Incidence of anaphylactoid reactions to isosulfan blue dye during breast carcinoma lymphatic mapping in patients treated with preoperative prophylaxis: results of a surgical prospective clinical practice protocol.

Authors:  Chandrajit P Raut; Kelly K Hunt; Jeri S Akins; M Denise Daley; Merrick I Ross; S Eva Singletary; Gailen D Marshall; Funda Meric-Bernstam; Gildy Babiera; Barry W Feig; Frederick C Ames; Henry M Kuerer
Journal:  Cancer       Date:  2005-08-15       Impact factor: 6.860

Review 3.  Focus on diagnosis: co-oximetry.

Authors:  Elizabeth Mack
Journal:  Pediatr Rev       Date:  2007-02

Review 4.  A cautionary tale: anaphylaxis to isosulfan blue dye after 12 years and 3339 cases of lymphatic mapping.

Authors:  Gabriel Kaufman; Amber A Guth; H Leon Pachter; Daniel F Roses
Journal:  Am Surg       Date:  2008-02       Impact factor: 0.688

Review 5.  A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.

Authors:  Sarmela Thevarajah; Tara L Huston; Rache M Simmons
Journal:  Am J Surg       Date:  2005-02       Impact factor: 2.565

6.  Anaphylaxis to isosulfan blue dye during sentinel lymph node biopsy.

Authors:  Sukhjit Sandhu; Ehab Farag; Maged Argalious
Journal:  J Clin Anesth       Date:  2005-12       Impact factor: 9.452

7.  Can methylene blue only be used in sentinel lymph node biopsy for breast cancer?

Authors:  Mehra Golshan; Faina Nakhlis
Journal:  Breast J       Date:  2006 Sep-Oct       Impact factor: 2.431

Review 8.  Anaphylaxis to isosulfan blue and cross-reactivity to patent blue V: case report and review of the nomenclature of vital blue dyes.

Authors:  Kathrin Scherer; Wolfgang Studer; Verena Figueiredo; Andreas J Bircher
Journal:  Ann Allergy Asthma Immunol       Date:  2006-03       Impact factor: 6.347

9.  Effect on oximetry of dyes used for sentinel lymph node biopsy.

Authors:  Antonio Piñero; Julián Illana; Carlos García-Palenciano; Francisco Cañizarese; Manuel Canteras; Victoria Cañadillas; Eugenia Durán; Pascual Parilla
Journal:  Arch Surg       Date:  2004-11

10.  Benzocaine and lidocaine induced methemoglobinemia after bronchoscopy: a case report.

Authors:  Sophie Kwok; Jacqueline L Fischer; John D Rogers
Journal:  J Med Case Rep       Date:  2008-01-23
View more
  3 in total

1.  Recent publications by ochsner authors.

Authors: 
Journal:  Ochsner J       Date:  2012

2.  Isosulfan Blue and Anaphylaxis.

Authors:  Abin Sajan; Daniel W Griepp; Hazim Hakmi; Amir H Sohail; Jackson Hunt; Michelle Wolf; Zhanna Logman
Journal:  Ochsner J       Date:  2021

Review 3.  Interference of medical contrast media on laboratory testing.

Authors:  Giuseppe Lippi; Massimo Daves; Camilla Mattiuzzi
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.