Half-scan fan-beam computed tomography with improved noise and resolution properties.

Lifeng Yu1, Xiaochuan Pan.   

Abstract

Half-scan strategy can be used for reducing scanning time and radiation dose delivered to the patient in fan-beam computed tomography (CT). In helical CT, the data weighting/interpolation functions are often devised based upon half-scan configurations. The half-scan fan-beam filtered backprojection (FFBP) algorithm is generally used for image reconstruction from half-scan data. It can, however, be susceptible to sample aliasing and data noise for configurations with short focal lengths and/or large fan-angles, leading to nonuniform resolution and noise properties in reconstructed images. Uniform resolution and noise properties are generally desired because they may lead to an increased utility of reconstructed images in estimation and/or detection/classification tasks. In this work, we propose an algorithm for reconstruction of images with uniform noise and resolution properties in half-scan CT. In an attempt to evaluate the image-noise properties, we derive analytic expressions for image variances obtained by use of the half-scan algorithms. We also perform numerical studies to assess quantitatively the resolution and noise properties of the algorithms. The results in these studies confirm that the proposed algorithm yields images with more uniform spatial resolution and with lower and more uniform noise levels than does the half-scan FFBP algorithm. Empirical results obtained in noise studies also verify the validity of the derived expressions for image variances. The proposed algorithm would be particularly useful for image reconstruction from data acquired by use of configurations with short focal lengths and large field of measurement, which may be encountered in compact micro-CT and radiation therapeutic CT applications. The analytic results of the image-noise properties can be used for image-quality assessment in detection/classification tasks by use of model-observers.

Entities:  

Mesh:

Year:  2003        PMID: 14596299     DOI: 10.1118/1.1607507

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Authors:  Adam Wunderlich; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

2.  Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.

Authors:  Richard Taschereau; Patrick L Chow; Arion F Chatziioannou
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

3.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

4.  Image reconstruction in reduced circular sinusoidal cone-beam CT.

Authors:  Dan Xia; Seungryong Cho; Xiaochuan Pan
Journal:  J Xray Sci Technol       Date:  2009       Impact factor: 1.535

5.  Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging.

Authors:  Pascal Theriault Lauzier; Jie Tang; Michael A Speidel; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

6.  Evidence-based recommendations for musculoskeletal kinematic 4D-CT studies using wide area-detector scanners: a phantom study with cadaveric correlation.

Authors:  Pedro Augusto Gondim Teixeira; Anne-Sophie Formery; Gabriela Hossu; Daniel Winninger; Toufik Batch; Alban Gervaise; Alain Blum
Journal:  Eur Radiol       Date:  2016-04-19       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.