Literature DB >> 20208096

An image-based skeletal dosimetry model for the ICRP reference newborn--internal electron sources.

Deanna Pafundi1, Didier Rajon, Derek Jokisch, Choonsik Lee, Wesley Bolch.   

Abstract

In this study, a comprehensive electron dosimetry model of newborn skeletal tissues is presented. The model is constructed using the University of Florida newborn hybrid phantom of Lee et al (2007 Phys. Med. Biol. 52 3309-33), the newborn skeletal tissue model of Pafundi et al (2009 Phys. Med. Biol. 54 4497-531) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow (surrogate tissue for hematopoietic stem cells), shallow marrow (surrogate tissue for osteoprogenitor cells) and unossified cartilage (surrogate tissue for chondrocytes). Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following source tissues: active marrow, trabecular bone (surfaces and volumes), cortical bone (surfaces and volumes) and cartilage. Transport results are reported as specific absorbed fractions according to the MIRD schema and are given as skeletal-averaged values in the paper with bone-specific values reported in both tabular and graphic format as electronic annexes (supplementary data). The method utilized in this work uniquely includes (1) explicit accounting for the finite size and shape of newborn ossification centers (spongiosa regions), (2) explicit accounting for active and shallow marrow dose from electron emissions in cortical bone as well as sites of unossified cartilage, (3) proper accounting of the distribution of trabecular and cortical volumes and surfaces in the newborn skeleton when considering mineral bone sources and (4) explicit consideration of the marrow cellularity changes for active marrow self-irradiation as applicable to radionuclide therapy of diseased marrow in the newborn child.

Entities:  

Mesh:

Year:  2010        PMID: 20208096     DOI: 10.1088/0031-9155/55/7/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  An image-based skeletal dosimetry model for the ICRP reference adult male--internal electron sources.

Authors:  Matthew Hough; Perry Johnson; Didier Rajon; Derek Jokisch; Choonsik Lee; Wesley Bolch
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

2.  Patient-specific dosimetry using pretherapy [¹²⁴I]m-iodobenzylguanidine ([¹²⁴I]mIBG) dynamic PET/CT imaging before [¹³¹I]mIBG targeted radionuclide therapy for neuroblastoma.

Authors:  Shih-ying Huang; Wesley E Bolch; Choonsik Lee; Henry F Van Brocklin; Miguel H Pampaloni; Randall A Hawkins; Aimee Sznewajs; Steven G DuBois; Katherine K Matthay; Youngho Seo
Journal:  Mol Imaging Biol       Date:  2015-04       Impact factor: 3.488

Review 3.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

4.  Depth-dependent concentrations of hematopoietic stem cells in the adult skeleton: Implications for active marrow dosimetry.

Authors:  Amy M Geyer; Bryan C Schwarz; Shannon E O'Reilly; Robert F Hobbs; George Sgouros; Wesley E Bolch
Journal:  Med Phys       Date:  2017-01-30       Impact factor: 4.071

5.  Internal photon and electron dosimetry of the newborn patient--a hybrid computational phantom study.

Authors:  Michael Wayson; Choonsik Lee; George Sgouros; S Ted Treves; Eric Frey; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2012-03-07       Impact factor: 3.609

6.  An image-based skeletal dosimetry model for the ICRP reference adult female-internal electron sources.

Authors:  Shannon E O'Reilly; Lindsay S DeWeese; Matthew R Maynard; Didier A Rajon; Michael B Wayson; Emily L Marshall; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2016-11-29       Impact factor: 3.609

7.  Active bone marrow S-values for the low-energy electron emitter terbium-161 compared to S-values for lutetium-177 and yttrium-90.

Authors:  Jens Hemmingsson; Johanna Svensson; Nicholas P van der Meulen; Cristina Müller; Peter Bernhardt
Journal:  EJNMMI Phys       Date:  2022-09-24
  7 in total