Literature DB >> 20206986

Effect of different surface pre-treatments and luting materials on shear bond strength to PEEK.

Patrick R Schmidlin1, Bogna Stawarczyk, Marco Wieland, Thomas Attin, Christoph H F Hämmerle, Jens Fischer.   

Abstract

OBJECTIVES: To assess the bonding potential of a universal composite resin cement and an adhesive/composite system to differently pre-treated PEEK surfaces.
METHODS: One hundred and fifty PEEK disks were embedded in epoxy resin, polished (P4000 grit) and treated as follows (n=30/group): (A) no treatment, (B) acid etching with sulfuric acid (98%) for 1 min, (C) sandblasting for 10s with 50 microm alumina, (D) sandblasting for 10s with 110 microm alumina and (E) silica coating using the Rocatec system (3M ESPE). Polished and sandblasted (50 microm alumina) cp titanium (grade 4) served as a control. Acrylic hollow cylinders were either luted with a universal composite resin cement (RelyX Unicem) or an unfilled resin (Heliobond) and a hybrid composite (Tetric) to the specimens. Bond strength was measured in a shear test and failure modes were assessed. Statistic analysis was performed with one-way ANOVA followed by a post hoc Scheffé test and unpaired t-tests.
RESULTS: With the universal composite resin cement, no bond could be established on any PEEK surfaces, except specimens etched with sulfuric acid (19.0+/-3.4MPa). Shear bond strength to titanium was significantly lower (8.7+/-2.8MPa, p<0.05). Applying the adhesive/composite system, shear bond strength values on pre-treated PEEK ranged from 11.5+/-3.2MPa (silica coating) to 18.2+/-5.4MPa (acid etched) with no statistically significant differences (p>0.05). No bond was obtained on the polished surface. SIGNIFICANCE: Bonding to PEEK is possible when using a bonding system. No adherence can be achieved with the tested universal composite resin cement except on an etched surface. The results strongly encourage further research in PEEK application in dentistry. Copyright (c) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20206986     DOI: 10.1016/j.dental.2010.02.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  27 in total

1.  Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Authors:  Merve Benli; Beril Eker Gümüş; Yusuf Kahraman; Bilge Gökçen-Rohlig; Gülümser Evlioğlu; Olivier Huck; Mutlu Özcan
Journal:  Odontology       Date:  2019-10-14       Impact factor: 2.634

2.  Influence of dentin and enamel pretreatment with acidic sulfur compounds on adhesive performance.

Authors:  Alexis Ioannidis; Bogna Stawarczyk; Beatrice Sener; Thomas Attin; Patrick R Schmidlin
Journal:  Clin Oral Investig       Date:  2012-11-09       Impact factor: 3.573

3.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

4.  Effect of Surface Treatment With Er:YAG and CO2 Lasers on Shear Bond Strength of Polyether Ether Ketone to Composite Resin Veneers.

Authors:  Yousef Jahandideh; Mehran Falahchai; Hossein Pourkhalili
Journal:  J Lasers Med Sci       Date:  2020-03-15

5.  Influence of caries infiltrant contamination on shear bond strength of different adhesives to dentin.

Authors:  Liuhe Jia; Bogna Stawarczyk; Patrick R Schmidlin; Thomas Attin; Annette Wiegand
Journal:  Clin Oral Investig       Date:  2012-04-25       Impact factor: 3.573

6.  Bonding of composite resins to PEEK: the influence of adhesive systems and air-abrasion parameters.

Authors:  Bogna Stawarczyk; Simon Taufall; Malgorzata Roos; Patrick R Schmidlin; Nina Lümkemann
Journal:  Clin Oral Investig       Date:  2017-06-24       Impact factor: 3.573

7.  Shear bond strength between veneering composite and PEEK after different surface modifications.

Authors:  Martin Rosentritt; Verena Preis; Michael Behr; Nuno Sereno; Carola Kolbeck
Journal:  Clin Oral Investig       Date:  2014-08-06       Impact factor: 3.573

8.  Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses.

Authors:  Simon Taufall; Marlis Eichberger; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2016-03-15       Impact factor: 3.573

9.  Influence of plasma pretreatment on shear bond strength of self-adhesive resin cements to polyetheretherketone.

Authors:  B Stawarczyk; N Bähr; F Beuer; T Wimmer; M Eichberger; W Gernet; D Jahn; P R Schmidlin
Journal:  Clin Oral Investig       Date:  2013-03-17       Impact factor: 3.573

10.  Evaluation of the effects of different surface modification methods on the bond strength of high-performance polymers and resin matrix ceramics.

Authors:  Büşra Tosun; Nuran Yanıkoğlu
Journal:  Clin Oral Investig       Date:  2022-01-24       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.