Literature DB >> 20199928

Auto-calibrated parallel imaging reconstruction for arbitrary trajectories using k-space sparse matrices (kSPA).

Chunlei Liu1, Jian Zhang, Michael E Moseley.   

Abstract

Image acquisition of magnetic resonance imaging (MRI) can be accelerated by using multiple receiving coils simultaneously. The problem of reconstructing an unaliased image from partially sampled k-space data can be formulated as a large system of sparse linear equations. The k-space sparse matrix (kSPA) algorithm proposes to solve the system of equations by finding a sparse approximate inverse. This algorithm has been shown to accelerate the image reconstruction for a large number of coils. The original kSPA algorithm requires knowledge of coil sensitivities. Here, we propose and demonstrate an auto-calibrated kSPA algorithm that does not require the explicit computation of the coil sensitivity maps. We have also shown that calibration data, in principle, can be acquired at any region of k-space. This property applies to arbitrary sampling trajectories and all reconstruction algorithms based on k-space. In practice, because of its higher SNR, calibration data acquired at the center of k-space performed more favorably. Such auto-calibration can be advantageous in cases where an accurate sensitivity map is difficult to obtain.

Entities:  

Mesh:

Year:  2010        PMID: 20199928      PMCID: PMC2996098          DOI: 10.1109/TMI.2010.2042299

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  27 in total

1.  Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE).

Authors:  R Bammer; S L Keeling; M Augustin; K P Pruessmann; R Wolf; R Stollberger; H P Hartung; F Fazekas
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

2.  VD-AUTO-SMASH imaging.

Authors:  R M Heidemann; M A Griswold; A Haase; P M Jakob
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

3.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Auto-SENSE perfusion imaging of the whole human heart.

Authors:  Herbert Köstler; Jörn J W Sandstede; Claudia Lipke; Wilfried Landschütz; Meinrad Beer; Dietbert Hahn
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

5.  Resolution enhancement in lung 1H imaging using parallel imaging methods.

Authors:  R M Heidemann; M A Griswold; B Kiefer; M Nittka; J Wang; V Jellus; P M Jakob
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

6.  Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.

Authors:  Chunlei Liu; Michael E Moseley; Roland Bammer
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

7.  Advances in locally constrained k-space-based parallel MRI.

Authors:  Alexey A Samsonov; Walter F Block; Arjun Arunachalam; Aaron S Field
Journal:  Magn Reson Med       Date:  2006-02       Impact factor: 4.668

8.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

9.  AUTO-SMASH: a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics.

Authors:  P M Jakob; M A Griswold; R R Edelman; D K Sodickson
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

10.  Spatially filtering functional magnetic resonance imaging data.

Authors:  M J Lowe; J A Sorenson
Journal:  Magn Reson Med       Date:  1997-05       Impact factor: 4.668

View more
  1 in total

1.  Sparse Parallel MRI Based on Accelerated Operator Splitting Schemes.

Authors:  Nian Cai; Weisi Xie; Zhenghang Su; Shanshan Wang; Dong Liang
Journal:  Comput Math Methods Med       Date:  2016-09-25       Impact factor: 2.238

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.