Literature DB >> 11550248

Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE).

R Bammer1, S L Keeling, M Augustin, K P Pruessmann, R Wolf, R Stollberger, H P Hartung, F Fazekas.   

Abstract

Diffusion-weighted single-shot EPI (sshEPI) is one of the most important tools for the diagnostic assessment of stroke patients, but it suffers from well known artifacts. Therefore, sshEPI was combined with SENSitivity Encoding (SENSE) to further increase EPI's potential for stroke imaging. Eight healthy volunteers and a consecutive series of patients (N = 8) with suspected stroke were examined with diffusion-weighted SENSE-sshEPI using different reduction factors (1.0 < or = R < or = 3.0). Additionally, a high-resolution diffusion-weighted SENSE-sshEPI scan was included. All examinations were diagnostic and of better quality than conventional sshEPI. No ghostings or aliasing artifacts were discernible, and EPI-related image distortions were markedly diminished. Chemical shift artifacts and eddy current-induced image warping were still present, although to a markedly smaller extent. Measured direction-dependent diffusion-coefficients and isotropic diffusion values were comparable to previous findings but showed less fluctuation. We have demonstrated the technical feasibility and clinical applicability of diffusion-weighted SENSE-sshEPI in patients with subacute stroke. Because of the faster k-space traversal, this novel technique is able to reduce typical EPI artifacts and increase spatial resolution while simultaneously remaining insensitive to bulk motion. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11550248     DOI: 10.1002/mrm.1226

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  63 in total

1.  Reconstruction of scattered data in fetal diffusion MRI.

Authors:  Estanislao Oubel; Mériam Koob; Colin Studholme; Jean-Louis Dietemann; François Rousseau
Journal:  Med Image Anal       Date:  2011-04-27       Impact factor: 8.545

2.  Clinical assessment of standard and generalized autocalibrating partially parallel acquisition diffusion imaging: effects of reduction factor and spatial resolution.

Authors:  J B Andre; G Zaharchuk; N J Fischbein; M Augustin; S Skare; M Straka; J Rosenberg; M G Lansberg; S Kemp; C A C Wijman; G W Albers; N E Schwartz; R Bammer
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

3.  Sensitivity-encoded diffusion tensor MR imaging of the cervical cord.

Authors:  Mara Cercignani; Mark A Horsfield; Federica Agosta; Massimo Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

Review 4.  [Diffusion tensor imaging. Theory, sequence optimization and application in Alzheimer's disease].

Authors:  B Stieltjes; M Schlüter; H K Hahn; T Wilhelm; M Essig
Journal:  Radiologe       Date:  2003-06-28       Impact factor: 0.635

5.  Motion-robust diffusion tensor acquisition at routine 3T magnetic resonance imaging.

Authors:  Hasina Yasmin; Hiroyuki Kabasawa; Shigeki Aoki; Osamu Abe; Yoshitaka Masutani; Naoto Hayashi; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2010-01-30       Impact factor: 2.374

Review 6.  Ultrafast inverse imaging techniques for fMRI.

Authors:  Fa-Hsuan Lin; Kevin W K Tsai; Ying-Hua Chu; Thomas Witzel; Aapo Nummenmaa; Tommi Raij; Jyrki Ahveninen; Wen-Jui Kuo; John W Belliveau
Journal:  Neuroimage       Date:  2012-01-21       Impact factor: 6.556

7.  High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.

Authors:  Ha-Kyu Jeong; John C Gore; Adam W Anderson
Journal:  Magn Reson Med       Date:  2012-05-16       Impact factor: 4.668

Review 8.  Foundations of advanced magnetic resonance imaging.

Authors:  Roland Bammer; Stefan Skare; Rexford Newbould; Chunlei Liu; Vincent Thijs; Stefan Ropele; David B Clayton; Gunnar Krueger; Michael E Moseley; Gary H Glover
Journal:  NeuroRx       Date:  2005-04

9.  Functional MRI using regularized parallel imaging acquisition.

Authors:  Fa-Hsuan Lin; Teng-Yi Huang; Nan-Kuei Chen; Fu-Nien Wang; Steven M Stufflebeam; John W Belliveau; Lawrence L Wald; Kenneth K Kwong
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

Review 10.  Diffusion-weighted breast MRI: Clinical applications and emerging techniques.

Authors:  Savannah C Partridge; Noam Nissan; Habib Rahbar; Averi E Kitsch; Eric E Sigmund
Journal:  J Magn Reson Imaging       Date:  2016-09-30       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.