Literature DB >> 20199906

Robust adaptive 3-D segmentation of vessel laminae from fluorescence confocal microscope images and parallel GPU implementation.

Arunachalam Narayanaswamy1, Saritha Dwarakapuram, Christopher S Bjornsson, Barbara M Cutler, William Shain, Badrinath Roysam.   

Abstract

This paper presents robust 3-D algorithms to segment vasculature that is imaged by labeling laminae, rather than the lumenal volume. The signal is weak, sparse, noisy, nonuniform, low-contrast, and exhibits gaps and spectral artifacts, so adaptive thresholding and Hessian filtering based methods are not effective. The structure deviates from a tubular geometry, so tracing algorithms are not effective. We propose a four step approach. The first step detects candidate voxels using a robust hypothesis test based on a model that assumes Poisson noise and locally planar geometry. The second step performs an adaptive region growth to extract weakly labeled and fine vessels while rejecting spectral artifacts. To enable interactive visualization and estimation of features such as statistical confidence, local curvature, local thickness, and local normal, we perform the third step. In the third step, we construct an accurate mesh representation using marching tetrahedra, volume-preserving smoothing, and adaptive decimation algorithms. To enable topological analysis and efficient validation, we describe a method to estimate vessel centerlines using a ray casting and vote accumulation algorithm which forms the final step of our algorithm. Our algorithm lends itself to parallel processing, and yielded an 8 x speedup on a graphics processor (GPU). On synthetic data, our meshes had average error per face (EPF) values of (0.1-1.6) voxels per mesh face for peak signal-to-noise ratios from (110-28 dB). Separately, the error from decimating the mesh to less than 1% of its original size, the EPF was less than 1 voxel/face. When validated on real datasets, the average recall and precision values were found to be 94.66% and 94.84%, respectively.

Entities:  

Mesh:

Year:  2010        PMID: 20199906      PMCID: PMC2852140          DOI: 10.1109/TMI.2009.2022086

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  25 in total

1.  An image analysis algorithm for dendritic spines.

Authors:  Ingrid Y Y Koh; W Brent Lindquist; Karen Zito; Esther A Nimchinsky; Karel Svoboda
Journal:  Neural Comput       Date:  2002-06       Impact factor: 2.026

2.  Detection and measurement of retinal vessels in fundus images using amplitude modified second-order Gaussian filter.

Authors:  Luo Gang; Opas Chutatape; Shankar M Krishnan
Journal:  IEEE Trans Biomed Eng       Date:  2002-02       Impact factor: 4.538

3.  Harmonic cut and regularized centroid transform for localization of subcellular structures.

Authors:  Qing Yang; Bahram Parvin
Journal:  IEEE Trans Biomed Eng       Date:  2003-04       Impact factor: 4.538

4.  Thin structure segmentation and visualization in three-dimensional biomedical images: a shape-based approach.

Authors:  Adam Huang; Gregory M Nielson; Anshuman Razdan; Gerald E Farin; D Page Baluch; David G Capco
Journal:  IEEE Trans Vis Comput Graph       Date:  2006 Jan-Feb       Impact factor: 4.579

5.  A 2-D/3-D model-based method to quantify the complexity of microvasculature imaged by in vivo multiphoton microscopy.

Authors:  James A Tyrrell; Vijay Mahadevan; Ricky T Tong; Edward B Brown; Rakesh K Jain; Badrinath Roysam
Journal:  Microvasc Res       Date:  2005-10-18       Impact factor: 3.514

Review 6.  Stem cells and their niches.

Authors:  Kateri A Moore; Ihor R Lemischka
Journal:  Science       Date:  2006-03-31       Impact factor: 47.728

7.  Optimal surface segmentation in volumetric images--a graph-theoretic approach.

Authors:  Kang Li; Xiaodong Wu; Danny Z Chen; Milan Sonka
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2006-01       Impact factor: 6.226

8.  Asymmetric distribution of EGFR receptor during mitosis generates diverse CNS progenitor cells.

Authors:  Yu Sun; Susan K Goderie; Sally Temple
Journal:  Neuron       Date:  2005-03-24       Impact factor: 17.173

9.  Robust 3-D modeling of vasculature imagery using superellipsoids.

Authors:  James Alexander Tyrrell; Emmanuelle di Tomaso; Daniel Fuja; Ricky Tong; Kevin Kozak; Rakesh K Jain; Badrinath Roysam
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

10.  Segmentation of wall and plaque in in vitro vascular MR images.

Authors:  Fuxing Yang; Gerhard Holzapfel; Christian Schulze-Bauer; Rudolf Stollberger; Daniel Thedens; Lizann Bolinger; Alan Stolpen; Milan Sonka
Journal:  Int J Cardiovasc Imaging       Date:  2003-10       Impact factor: 2.357

View more
  15 in total

1.  Real-time GPU-accelerated processing and volumetric display for wide-field laser-scanning optical-resolution photoacoustic microscopy.

Authors:  Heesung Kang; Sang-Won Lee; Eun-Soo Lee; Se-Hwa Kim; Tae Geol Lee
Journal:  Biomed Opt Express       Date:  2015-11-02       Impact factor: 3.732

2.  GPU accelerated segmentation and centerline extraction of tubular structures from medical images.

Authors:  Erik Smistad; Anne C Elster; Frank Lindseth
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-11-01       Impact factor: 2.924

3.  A broadly applicable 3-D neuron tracing method based on open-curve snake.

Authors:  Yu Wang; Arunachalam Narayanaswamy; Chia-Ling Tsai; Badrinath Roysam
Journal:  Neuroinformatics       Date:  2011-09

4.  Segmentation of biological images containing multitarget labeling using the jelly filling framework.

Authors:  Neeraj J Gadgil; Paul Salama; Kenneth W Dunn; Edward J Delp
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-23

5.  A survey of GPU-based medical image computing techniques.

Authors:  Lin Shi; Wen Liu; Heye Zhang; Yongming Xie; Defeng Wang
Journal:  Quant Imaging Med Surg       Date:  2012-09

6.  3D actin network centerline extraction with multiple active contours.

Authors:  Ting Xu; Dimitrios Vavylonis; Xiaolei Huang
Journal:  Med Image Anal       Date:  2013-11-16       Impact factor: 8.545

7.  Computer Vision Techniques for Transcatheter Intervention.

Authors:  Feng Zhao; Xianghua Xie; Matthew Roach
Journal:  IEEE J Transl Eng Health Med       Date:  2015-06-18       Impact factor: 3.316

8.  Algorithms for improved 3-D reconstruction of live mammalian embryo vasculature from optical coherence tomography data.

Authors:  Prathamesh M Kulkarni; Nicolas Rey-Villamizar; Amine Merouane; Narendran Sudheendran; Shang Wang; Monica Garcia; Irina V Larina; Badrinath Roysam; Kirill V Larin
Journal:  Quant Imaging Med Surg       Date:  2015-02

9.  Cerebral vascular structure in the motor cortex of adult mice is stable and is not altered by voluntary exercise.

Authors:  Robert H Cudmore; Sarah E Dougherty; David J Linden
Journal:  J Cereb Blood Flow Metab       Date:  2017-01-06       Impact factor: 6.200

10.  Three-dimensional vasculature reconstruction of tumour microenvironment via local clustering and classification.

Authors:  Yanqiao Zhu; Fuhai Li; Tegy J Vadakkan; Mei Zhang; John Landua; Wei Wei; Jinwen Ma; Mary E Dickinson; Jeffrey M Rosen; Michael T Lewis; Ming Zhan; Stephen T C Wong
Journal:  Interface Focus       Date:  2013-08-06       Impact factor: 3.906

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.