Literature DB >> 20195107

1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction.

Shareef Jandali1, Liza C Wu, Stephen J Vega, Stephen J Kovach, Joseph M Serletti.   

Abstract

BACKGROUND: Microvascular anastomosis is one of the more critical aspects of free flap surgery. A safe, effective, and expedient method for venous anastomosis minimizes flap ischemia time, is easier on the surgical team, and saves costly operating room time. The authors report on their experience using the Synovis microvascular anastomotic coupling device in 1000 consecutive venous anastomoses in free flap breast reconstruction.
METHODS: The authors retrospectively reviewed 1000 consecutive venous anastomoses that were performed using the microvascular anastomotic coupler between July of 2002 and July of 2008. Data were obtained on flap type, recipient vessel, coupler size, incidence of venous thrombosis, timing of venous thrombosis, and morbidity as a result of venous thrombosis.
RESULTS: All anastomoses were performed in an end-to-end fashion. There were 460 unilateral cases and 270 bilateral cases of breast reconstruction. Flap types included muscle-sparing free transverse rectus abdominis myocutaneous, deep inferior epigastric perforator, superficial inferior epigastric artery, superior gluteal artery perforator, and inferior gluteal artery perforator. The vast majority of the recipient vessels were the internal mammary or thoracodorsal vessels. Most of the couplers that were used were either 3 or 2.5 mm in diameter. Overall, there were six instances of venous thrombosis (rate of 0.6 percent). There were no total flap losses due to venous thrombosis in this series, although two patients had partial flap necrosis.
CONCLUSIONS: The patency rate for venous anastomoses performed with the microvascular coupler is excellent when compared with standard suture techniques and has the advantage of overall easier application.

Entities:  

Mesh:

Year:  2010        PMID: 20195107     DOI: 10.1097/PRS.0b013e3181cb636d

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  10 in total

1.  Venous Thrombosis in Handsewn versus Coupled Venous Anastomoses in 857 Consecutive Breast Free Flaps.

Authors:  Anita R Kulkarni; Babak J Mehrara; Andrea L Pusic; Peter G Cordeiro; Evan Matros; Colleen M McCarthy; Joseph J Disa
Journal:  J Reconstr Microsurg       Date:  2015-09-15       Impact factor: 2.873

2.  Microvascular anastomotic coupler assessment in head and neck reconstruction.

Authors:  John W Frederick; Larissa Sweeny; William R Carroll; Eben L Rosenthal
Journal:  Otolaryngol Head Neck Surg       Date:  2013-04-12       Impact factor: 3.497

3.  The utility of the microvascular anastomotic coupler in free tissue transfer.

Authors:  Amandeep S Grewal; Boban Erovic; Nick Strumas; Danny J Enepekides; Kevin M Higgins
Journal:  Can J Plast Surg       Date:  2012

4.  One Versus 2 Venous Anastomoses in Free Flap Surgery: A Systematic Review and Meta-Analysis.

Authors:  Jennifer L K Matthews; Noor Alolabi; Forough Farrokhyar; Sophocles H Voineskos
Journal:  Plast Surg (Oakv)       Date:  2017-11-21       Impact factor: 0.947

5.  Exposure of a microvascular anastomotic coupler in head and neck reconstruction: a case report.

Authors:  Tateki Kubo; Natsuko Kitamura; Motohiro Onoda; Daisuke Maeda; Ken Matsuda; Ko Hosokawa
Journal:  Eplasty       Date:  2014-04-09

6.  Protocol for a systematic review of venous coupler devices versus hand-sewn anastomosis for microsurgical free flap reconstruction.

Authors:  Timo Rodi; Alexander Geierlehner; Afshin Mosahebi; Grigorios Tanos; Justin Conrad Rosen Wormald
Journal:  Syst Rev       Date:  2018-11-13

Review 7.  Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?

Authors:  D D Krijgh; B Tellier; T Teunis; W Maarse; J H Coert
Journal:  JPRAS Open       Date:  2021-08-11

8.  The effect of CT angiography and venous couplers on surgery duration in microvascular breast reconstruction: a single operator's experience.

Authors:  Ledibabari Mildred Ngaage; Georgette Oni; Bruno Di Pace; Raed Rafat Hamed; Laura Fopp; Brendan Chuj Koo; Charles Musonda Malata
Journal:  Gland Surg       Date:  2018-10

9.  Interdisciplinary Treatment of Breast Cancer After Mastectomy With Autologous Breast Reconstruction Using Abdominal Free Flaps in a University Teaching Hospital-A Standardized and Safe Procedure.

Authors:  Dominik Steiner; Raymund E Horch; Ingo Ludolph; Marweh Schmitz; Justus P Beier; Andreas Arkudas
Journal:  Front Oncol       Date:  2020-03-05       Impact factor: 6.244

10.  Applying the Microvascular Anastomotic Coupler Device to End-to-side Venous Anastomosis in Reconstructive Surgery.

Authors:  Hiroki Umezawa; Yu Hokazono; Marie Taga; Rei Ogawa
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-01-14
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.