Literature DB >> 20187190

A three-dimensional variable-density spiral spatial-spectral RF pulse with rotated gradients.

Weiran Deng1, V Andrew Stenger.   

Abstract

Three-dimensional spatial-spectral radiofrequency pulses using a stack-of-spirals trajectory can achieve two-dimensional spatial localization and one-dimensional spectral selection simultaneously. These pulses are useful, for example, in reduced field-of-view applications that also require frequency specificity such as lipid imaging. A limitation of the pulse design is that the length of the spiral trajectory is fixed by the frequency separation of lipid and water. This restricts the highest possible excitation resolution of the spatial profile over a given field of excitation. In this work, we examine the use of periodically rotated variable-density spirals to increase the spatial excitation resolution without changing the frequency selectivity. Variable-density spirals are used to undersample the high spatial frequencies such that higher excitation resolutions can be obtained with a small expense in increased aliasing of the slice profile. The periodic rotation of the spiral trajectories reduces the impact of the undersampling by distributing the aliasing in the frequency domain. The technique is demonstrated with simulations, phantom studies, and imaging human leg muscle at 3 T. It was found in the human study that the spatial excitation resolution could be improved from 6 x 6 to 8 x 8 (matrix size over a fixed field of view) while decreasing aliasing by approximately 40-60%. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20187190      PMCID: PMC3041896          DOI: 10.1002/mrm.22209

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

4.  Variable-density spiral 3D tailored RF pulses.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

5.  Excitation UNFOLD (XUNFOLD) to improve the temporal resolution of multishot tailored RF pulses.

Authors:  V Andrew Stenger; Marius S Giurgi; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

6.  Simultaneous spatial and spectral selective excitation.

Authors:  C H Meyer; J M Pauly; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1990-08       Impact factor: 4.668

7.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

8.  Three-dimensional spectral-spatial excitation.

Authors:  G Morrell; A Macovski
Journal:  Magn Reson Med       Date:  1997-03       Impact factor: 4.668

9.  Skeletal muscle lipid concentration quantified by magnetic resonance imaging.

Authors:  Bret H Goodpaster; V Andrew Stenger; Fernando Boada; Therese McKolanis; Denise Davis; Robert Ross; David E Kelley
Journal:  Am J Clin Nutr       Date:  2004-05       Impact factor: 7.045

10.  Semi-automated segmentation and quantification of adipose tissue in calf and thigh by MRI: a preliminary study in patients with monogenic metabolic syndrome.

Authors:  Salam A Al-Attar; Rebecca L Pollex; John F Robinson; Brooke A Miskie; Rhonda Walcarius; Brian K Rutt; Robert A Hegele
Journal:  BMC Med Imaging       Date:  2006-08-31       Impact factor: 1.930

View more
  1 in total

1.  Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.

Authors:  Jun Ma; Carrie Wismans; Zhipeng Cao; Dennis W J Klomp; Jannie P Wijnen; William A Grissom
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.