Literature DB >> 9055228

Three-dimensional spectral-spatial excitation.

G Morrell1, A Macovski.   

Abstract

A method of three-dimensional spectral-spatial excitation is presented which is selective simultaneously in two spatial dimensions and in the spectral or chemical shift dimension. This method can be used to create spectral passbands whose center frequency varies as a function of spatial location within an imaging plane. This variation of passband center frequency may be specified by an acquired main field (B0) map; the resulting excitations compensate for inhomogeneity of the B0 field. In vivo images are presented in which three-dimensional spectral-spatial excitation allows selective water-only imaging in the presence of large B0 inhomogeneity where conventional spectrally selective imaging falls. Phantom studies give a detailed profile of the performance of three-dimensional spectral-spatial pulses suitable for water-only or fat-saturation imaging. These pulses may also be useful for fat and water suppression in spectroscopic imaging. Performance constraints imposed by limited gradient slew rates are analyzed and quantified.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9055228     DOI: 10.1002/mrm.1910370314

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  On spatially selective RF excitation and its analogy with spiral MR image acquisition.

Authors:  P Börnert; B Aldefeld
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

2.  Broadband slab selection with B1+ mitigation at 7T via parallel spectral-spatial excitation.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; L L Wald; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

3.  A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities.

Authors:  Paul Kyu Han; Chao Ma; Kexin Deng; Shuang Hu; Kyung-Wook Jee; Kui Ying; Yen-Lin Chen; Georges El Fakhri
Journal:  Magn Reson Imaging       Date:  2017-09-14       Impact factor: 2.546

4.  A three-dimensional variable-density spiral spatial-spectral RF pulse with rotated gradients.

Authors:  Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

5.  Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.

Authors:  Jun Ma; Carrie Wismans; Zhipeng Cao; Dennis W J Klomp; Jannie P Wijnen; William A Grissom
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

6.  Parallel transmit optimized 3D composite adiabatic spectral-spatial pulse for spectroscopy.

Authors:  Xiaoxuan He; Edward J Auerbach; Michael Garwood; Naoharu Kobayashi; Xiaoping Wu; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2021-01-26       Impact factor: 3.737

7.  Improved first-pass spiral myocardial perfusion imaging with variable density trajectories.

Authors:  Michael Salerno; Christopher Sica; Christopher M Kramer; Craig H Meyer
Journal:  Magn Reson Med       Date:  2012-12-27       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.