Marieke Heisen1, Xiaobing Fan, Johannes Buurman, Natal A W van Riel, Gregory S Karczmar, Bart M ter Haar Romeny.
Abstract
We investigated the influence of the temporal resolution of dynamic contrast-enhanced MRI data on pharmacokinetic parameter estimation. Dynamic Gd-DTPA (Gadolinium-diethylene triamine pentaacetic acid) enhanced MRI data of implanted prostate tumors on rat hind limb were acquired at 4.7 T, with a temporal resolution of approximately 5 sec. The data were subsequently downsampled to temporal resolutions in the range of 15 sec to 85 sec, using a strategy that involves a recombination of k-space data. A basic two-compartment model was fit to the contrast agent uptake curves. The results demonstrated that as temporal resolution decreases, the volume transfer constant (K(trans)) is progressively underestimated (approximately 4% to approximately 25%), and the fractional extravascular extracellular space (v(e)) is progressively overestimated (approximately 1% to approximately 10%). The proposed downsampling strategy simulates the influence of temporal resolution more realistically than simply downsampling by removing samples. (c) 2010 Wiley-Liss, Inc.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20187187 PMCID: PMC3076555 DOI: 10.1002/mrm.22171