Literature DB >> 27215931

Accelerated Brain DCE-MRI Using Iterative Reconstruction With Total Generalized Variation Penalty for Quantitative Pharmacokinetic Analysis: A Feasibility Study.

Chunhao Wang1,2, Fang-Fang Yin1,2, John P Kirkpatrick1,2, Zheng Chang1,2.   

Abstract

PURPOSE: To investigate the feasibility of using undersampled k-space data and an iterative image reconstruction method with total generalized variation penalty in the quantitative pharmacokinetic analysis for clinical brain dynamic contrast-enhanced magnetic resonance imaging.
METHODS: Eight brain dynamic contrast-enhanced magnetic resonance imaging scans were retrospectively studied. Two k-space sparse sampling strategies were designed to achieve a simulated image acquisition acceleration factor of 4. They are (1) a golden ratio-optimized 32-ray radial sampling profile and (2) a Cartesian-based random sampling profile with spatiotemporal-regularized sampling density constraints. The undersampled data were reconstructed to yield images using the investigated reconstruction technique. In quantitative pharmacokinetic analysis on a voxel-by-voxel basis, the rate constant Ktrans in the extended Tofts model and blood flow FB and blood volume VB from the 2-compartment exchange model were analyzed. Finally, the quantitative pharmacokinetic parameters calculated from the undersampled data were compared with the corresponding calculated values from the fully sampled data. To quantify each parameter's accuracy calculated using the undersampled data, error in volume mean, total relative error, and cross-correlation were calculated.
RESULTS: The pharmacokinetic parameter maps generated from the undersampled data appeared comparable to the ones generated from the original full sampling data. Within the region of interest, most derived error in volume mean values in the region of interest was about 5% or lower, and the average error in volume mean of all parameter maps generated through either sampling strategy was about 3.54%. The average total relative error value of all parameter maps in region of interest was about 0.115, and the average cross-correlation of all parameter maps in region of interest was about 0.962. All investigated pharmacokinetic parameters had no significant differences between the result from original data and the reduced sampling data.
CONCLUSION: With sparsely sampled k-space data in simulation of accelerated acquisition by a factor of 4, the investigated dynamic contrast-enhanced magnetic resonance imaging pharmacokinetic parameters can accurately estimate the total generalized variation-based iterative image reconstruction method for reliable clinical application.

Entities:  

Keywords:  DCE-MRI; brain; iterative reconstruction; pharmacokinetic analysis; total generalized variation

Mesh:

Substances:

Year:  2016        PMID: 27215931      PMCID: PMC5616060          DOI: 10.1177/1533034616649294

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  62 in total

1.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

2.  Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging.

Authors:  Kenya Murase
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

Review 3.  Functional MRI for radiotherapy dose painting.

Authors:  Uulke A van der Heide; Antonetta C Houweling; Greetje Groenendaal; Regina G H Beets-Tan; Philippe Lambin
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

4.  Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model.

Authors:  Thomas E Yankeelov; Jeffrey J Luci; Martin Lepage; Rui Li; Laura Debusk; P Charles Lin; Ronald R Price; John C Gore
Journal:  Magn Reson Imaging       Date:  2005-05       Impact factor: 2.546

5.  Highly accelerated MRI by skipped phase encoding and edge deghosting with array coil enhancement (SPEED-ACE).

Authors:  Zheng Chang; Qing-San Xiang
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

6.  Quantification of cerebral blood flow, cerebral blood volume, and blood-brain-barrier leakage with DCE-MRI.

Authors:  Steven Sourbron; Michael Ingrisch; Axel Siefert; Maximilian Reiser; Karin Herrmann
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

7.  Sodium MRI using a density-adapted 3D radial acquisition technique.

Authors:  Armin M Nagel; Frederik B Laun; Marc-André Weber; Christian Matthies; Wolfhard Semmler; Lothar R Schad
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

Review 8.  Review of treatment assessment using DCE-MRI in breast cancer radiation therapy.

Authors:  Chun-Hao Wang; Fang-Fang Yin; Janet Horton; Zheng Chang
Journal:  World J Methodol       Date:  2014-06-26

9.  Sensitivity of quantitative metrics derived from DCE MRI and a pharmacokinetic model to image quality and acquisition parameters.

Authors:  Yue Cao; Diana Li; Zhou Shen; Daniel Normolle
Journal:  Acad Radiol       Date:  2010-04       Impact factor: 3.173

10.  Parallel imaging with nonlinear reconstruction using variational penalties.

Authors:  Florian Knoll; Christian Clason; Kristian Bredies; Martin Uecker; Rudolf Stollberger
Journal:  Magn Reson Med       Date:  2011-06-27       Impact factor: 4.668

View more
  4 in total

1.  Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study.

Authors:  Wendy Harris; Fang-Fang Yin; Chunhao Wang; You Zhang; Jing Cai; Lei Ren
Journal:  Phys Med Biol       Date:  2017-12-14       Impact factor: 3.609

2.  Augmentation of CBCT Reconstructed From Under-Sampled Projections Using Deep Learning.

Authors:  Zhuoran Jiang; Yingxuan Chen; Yawei Zhang; Yun Ge; Fang-Fang Yin; Lei Ren
Journal:  IEEE Trans Med Imaging       Date:  2019-04-23       Impact factor: 10.048

3.  Development of a Computerized 4-D MRI Phantom for Liver Motion Study.

Authors:  Chunhao Wang; Fang-Fang Yin; W P Segars; Zheng Chang; Lei Ren
Journal:  Technol Cancer Res Treat       Date:  2017-08-09

4.  Volumetric cine magnetic resonance imaging (VC-MRI) using motion modeling, free-form deformation and multi-slice undersampled 2D cine MRI reconstructed with spatio-temporal low-rank decomposition.

Authors:  Wendy Harris; Fang-Fang Yin; Jing Cai; Lei Ren
Journal:  Quant Imaging Med Surg       Date:  2020-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.