Literature DB >> 20186440

Loads on a spinal implant measured in vivo during whole-body vibration.

Antonius Rohlmann1, Barbara Hinz, Ralph Blüthner, Friedmar Graichen, Georg Bergmann.   

Abstract

After spinal surgery, patients often want to know whether driving a car or using public transportation can be dangerous for their spine. In order to answer this question, a clinically proven vertebral body replacement (VBR) has been modified. Six load sensors and a telemetry unit were integrated into the inductively powered implant. The modified implant allows the measurement of six load components. Telemeterized devices were implanted in five patients; four of them agreed to exposure themselves to whole-body vibration. During the measurements, the patients sat on a driver seat fixed to a hexapod. They were exposed to random single-axis vibrations in X, Y, and Z directions as well as in multi-axis XYZ directions with frequencies between 0.3 and 30 Hz. Three intensity levels (unweighted root mean square values of 0.25, 0.5 and 1.0 m/s(2)) were applied. Three postures were studied: sitting freely, using a vertical backrest, and a backrest declined by an angle of 25 degrees . The patients held their hands on their thighs. As expected, the maximum force on the VBR increased with increasing intensity and the number of axes. For the highest intensity level and multi-axis vibration, the maximum forces increased by 89% compared to sitting relaxed. Leaning at the backrest as well as lower intensity levels markedly decreased the implant loads. Driving a car or using public transportation systems-when the patient leans towards the backrest-leads to lower implant loads than walking, and can therefore be allowed already shortly after surgery.

Entities:  

Mesh:

Year:  2010        PMID: 20186440      PMCID: PMC2900023          DOI: 10.1007/s00586-010-1346-5

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  12 in total

1.  Intradiscal pressure together with anthropometric data--a data set for the validation of models.

Authors:  H Wilke; P Neef; B Hinz; H Seidel; L Claes
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001       Impact factor: 2.063

2.  Application of finite-element models to predict forces acting on the lumbar spine during whole-body vibration.

Authors:  H Seidel; R Blüthner; B Hinz
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001       Impact factor: 2.063

3.  An updated review of epidemiologic studies on the relationship between exposure to whole-body vibration and low back pain (1986-1997).

Authors:  M Bovenzi; C T Hulshof
Journal:  Int Arch Occup Environ Health       Date:  1999-09       Impact factor: 3.015

4.  Loads on an internal spinal fixation device during sitting.

Authors:  A Rohlmann; U Arntz; F Graichen; G Bergmann
Journal:  J Biomech       Date:  2001-08       Impact factor: 2.712

Review 5.  Whole-body vibration and low back pain: a systematic, critical review of the epidemiological literature 1992-1999.

Authors:  S Lings; C Leboeuf-Yde
Journal:  Int Arch Occup Environ Health       Date:  2000-07       Impact factor: 3.015

6.  Effects of fusion-bone stiffness on the mechanical behavior of the lumbar spine after vertebral body replacement.

Authors:  Antonius Rohlmann; Thomas Zander; Georg Bergmann
Journal:  Clin Biomech (Bristol, Avon)       Date:  2005-12-13       Impact factor: 2.063

Review 7.  On the relationship between whole-body vibration exposure and spinal health risk.

Authors:  Helmut Seidel
Journal:  Ind Health       Date:  2005-07       Impact factor: 2.179

Review 8.  Long-term effects of whole-body vibration: a critical survey of the literature.

Authors:  H Seidel; R Heide
Journal:  Int Arch Occup Environ Health       Date:  1986       Impact factor: 3.015

Review 9.  Selected health risks caused by long-term, whole-body vibration.

Authors:  H Seidel
Journal:  Am J Ind Med       Date:  1993-04       Impact factor: 2.214

10.  Large sizes of vertebral body replacement do not reduce the contact pressure on adjacent vertebral bodies per se.

Authors:  Thomas Zander; Georg Bergmann; Antonius Rohlmann
Journal:  Med Eng Phys       Date:  2009-09-19       Impact factor: 2.242

View more
  8 in total

1.  In vivo measurements of the effect of whole body vibration on spinal loads.

Authors:  Antonius Rohlmann; Hendrik Schmidt; Ulf Gast; Ines Kutzner; Philipp Damm; Georg Bergmann
Journal:  Eur Spine J       Date:  2013-11-08       Impact factor: 3.134

Review 2.  'SMART' implantable devices for spinal implants: a systematic review on current and future trends.

Authors:  Sihyong J Kim; Tian Wang; Matthew H Pelletier; William R Walsh
Journal:  J Spine Surg       Date:  2022-03

3.  Monitoring the load on a telemeterised vertebral body replacement for a period of up to 65 months.

Authors:  A Rohlmann; M Dreischarf; T Zander; F Graichen; P Strube; H Schmidt; G Bergmann
Journal:  Eur Spine J       Date:  2013-10-17       Impact factor: 3.134

4.  Activities of everyday life with high spinal loads.

Authors:  Antonius Rohlmann; David Pohl; Alwina Bender; Friedmar Graichen; Jörn Dymke; Hendrik Schmidt; Georg Bergmann
Journal:  PLoS One       Date:  2014-05-27       Impact factor: 3.240

5.  Loading of the hip and knee joints during whole body vibration training.

Authors:  Georg Bergmann; Ines Kutzner; Alwina Bender; Jörn Dymke; Adam Trepczynski; Georg N Duda; Dieter Felsenberg; Philipp Damm
Journal:  PLoS One       Date:  2018-12-12       Impact factor: 3.240

6.  Spinal loads during cycling on an ergometer.

Authors:  Antonius Rohlmann; Thomas Zander; Friedmar Graichen; Hendrik Schmidt; Georg Bergmann
Journal:  PLoS One       Date:  2014-04-17       Impact factor: 3.240

7.  Spinal loads during post-operative physiotherapeutic exercises.

Authors:  Antonius Rohlmann; Verena Schwachmeyer; Friedmar Graichen; Georg Bergmann
Journal:  PLoS One       Date:  2014-07-07       Impact factor: 3.240

Review 8.  Comparison of In Vivo Intradiscal Pressure between Sitting and Standing in Human Lumbar Spine: A Systematic Review and Meta-Analysis.

Authors:  Jia-Qi Li; Wai-Hang Kwong; Yuk-Lam Chan; Masato Kawabata
Journal:  Life (Basel)       Date:  2022-03-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.