Application of finite-element models to predict forces acting on the lumbar spine during whole-body vibration.

H Seidel1, R Blüthner, B Hinz.   

Abstract

OBJECTIVE: To predict forces acting on the spine during whole-body vibration for a variety of boundary conditions - body mass, height and posture.Design. Representative anthropometric data and models for an upright, relaxed and bent forward sitting posture were used to derive model families with 30 variants of a finite-element model.
BACKGROUND: A given exposure to whole-body vibration can cause a variable health risk depending on the concomitant conditions. The latter could contribute to the considerable uncertainty of the current evaluation of whole-body vibration.
METHODS: Plane symmetric linear finite-element models were used for the prediction of static and dynamic compression and shear forces acting on the lumbar discs during whole-body vibration. Transfer functions from seat acceleration to forces were determined.
RESULTS: A bent forward posture augments essentially the compressive and shear stress, predicted for erect and relaxed sitting postures. The normal variation of body mass and height causes a considerable variation of static internal shear stress, but a minor variation of compressive pressure. The dynamic internal stress varies nearly proportionally to the body mass. The transfer functions from seat acceleration to compressive force depend significantly on the posture.
CONCLUSIONS: The variability of the spinal loads for a given whole-body vibration and associated with a normal range of several biological factors suggests a ratio between the minimum and maximum internal loads of about 1:2. RELEVANCE: Finite-element models can be used to compare the health risk arising from different whole-body vibration exposures and individual conditions. These results help to prevent work-related disorders of the lumbar spine.

Mesh:

Year:  2001        PMID: 11275343     DOI: 10.1016/s0268-0033(00)00106-6

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

1.  Loads on a spinal implant measured in vivo during whole-body vibration.

Authors:  Antonius Rohlmann; Barbara Hinz; Ralph Blüthner; Friedmar Graichen; Georg Bergmann
Journal:  Eur Spine J       Date:  2010-02-27       Impact factor: 3.134

2.  Relationships of low back outcomes to internal spinal load: a prospective cohort study of professional drivers.

Authors:  Massimo Bovenzi; Marianne Schust; Gerhard Menzel; Andrea Prodi; Marcella Mauro
Journal:  Int Arch Occup Environ Health       Date:  2014-09-14       Impact factor: 3.015

3.  A prospective cohort study of low-back outcomes and alternative measures of cumulative external and internal vibration load on the lumbar spine of professional drivers.

Authors:  Massimo Bovenzi; Marianne Schust
Journal:  Scand J Work Environ Health       Date:  2021-02-01       Impact factor: 5.024

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.