Literature DB >> 20186285

An SVD Investigation of Modeling Scatter in Multiple Energy Windows for Improved SPECT Images.

Dan J Kadrmas1, Eric C Frey, Benjamin M W Tsui.   

Abstract

In this work singular value decomposition (SVD) techniques are used to investigate how the use of low energy photons and multiple energy windows affects the noise properties of Tc-99m SPECT imaging. We have previously shown that, when modeling scatter in the projector and backprojector of iterative reconstruction algorithms, simultaneous reconstruction from multiple energy window data can result in very different noise characteristics. Further, the properties depend upon the width and number of energy windows used. To investigate this further, we have generated photon transport matrices using models for scatter, an elliptical phantom containing cold rods of various sizes, and a number of multiple energy window acquisition schemes. Transfer matrices were also generated for the cases of perfect scatter rejection and ideal scatter subtraction. The matrices were decomposed using SVD, and signal power and projection space variance spectra were computed using the basis formed by the left singular vectors. Results indicate very different noise levels for the various energy window combinations. The perfect scatter rejection case resulted in the lowest variance spectrum, and reconstruction-based scatter compensation performed better than the scatter subtraction case. When including lower energy photons in reconstruction-based scatter compensation, using a series of multiple energy windows outperformed a single large energy window. One multiple window combination is presented which achieves a lower variance spectrum than the standard 20% energy window, indicating the potential for using low energy photons to improve the noise characteristics of SPECT images.

Entities:  

Year:  1996        PMID: 20186285      PMCID: PMC2827880          DOI: 10.1109/23.531892

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  9 in total

1.  A dual-photopeak window method for scatter correction.

Authors:  M A King; G J Hademenos; S J Glick
Journal:  J Nucl Med       Date:  1992-04       Impact factor: 10.057

2.  Reconstruction of SPECT images using generalized matrix inverses.

Authors:  M F Smith; C R Floyd; R J Jaszczak; R E Coleman
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

4.  SPECT Compton-scattering correction by analysis of energy spectra.

Authors:  K F Koral; X Q Wang; W L Rogers; N H Clinthorne; X H Wang
Journal:  J Nucl Med       Date:  1988-02       Impact factor: 10.057

5.  The noise power spectrum of CT images.

Authors:  M F Kijewski; P F Judy
Journal:  Phys Med Biol       Date:  1987-05       Impact factor: 3.609

6.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT.

Authors:  T Ichihara; K Ogawa; N Motomura; A Kubo; S Hashimoto
Journal:  J Nucl Med       Date:  1993-12       Impact factor: 10.057

7.  Improved SPECT quantification using compensation for scattered photons.

Authors:  R J Jaszczak; K L Greer; C E Floyd; C C Harris; R E Coleman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

8.  Subtraction of Compton-scattered photons in single-photon emission computerized tomography.

Authors:  B Axelsson; P Msaki; A Israelsson
Journal:  J Nucl Med       Date:  1984-04       Impact factor: 10.057

9.  The noise power spectrum in computed X-ray tomography.

Authors:  S J Riederer; N J Pelc; D A Chesler
Journal:  Phys Med Biol       Date:  1978-05       Impact factor: 3.609

  9 in total
  5 in total

1.  Application of reconstruction-based scatter compensation to thallium-201 SPECT: implementations for reduced reconstructed image noise.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  IEEE Trans Med Imaging       Date:  1998-06       Impact factor: 10.048

2.  Analysis of the reconstructibility and noise properties of scattered photons in 99mTc SPECT.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

3.  Singular value decomposition for photon-processing nuclear imaging systems and applications for reconstruction and computing null functions.

Authors:  Abhinav K Jha; Harrison H Barrett; Eric C Frey; Eric Clarkson; Luca Caucci; Matthew A Kupinski
Journal:  Phys Med Biol       Date:  2015-09-09       Impact factor: 3.609

4.  An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability.

Authors:  Xin He; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

5.  Singular value decomposition analysis of a photoacoustic imaging system and 3D imaging at 0.7 FPS.

Authors:  Michael B Roumeliotis; Robert Z Stodilka; Mark A Anastasio; Eldon Ng; Jeffrey J L Carson
Journal:  Opt Express       Date:  2011-07-04       Impact factor: 3.894

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.