Microbubbles as x-ray scattering contrast agents using analyzer-based imaging.

F Arfelli1, L Rigon, R H Menk.   

Abstract

Conventional contrast agents utilized in diagnostic radiology are based on x-ray absorption properties; alternative physical principles capable of providing a contrast enhancement in radiographs have never been applied. This study exploits the possibility of using a novel type of contrast media based on x-ray scattering. The contrast agents consist of microbubble echo-enhancing agents, usually applied in ultrasound examinations, which are invisible with conventional x-ray absorption techniques. The experiment was carried out at the medical beamline of the synchrotron radiation laboratory ELETTRA in Trieste, Italy. A flat silicon analyzer crystal typically used for diffraction-enhanced imaging was utilized as a tool for detecting the scattering properties of the contrast agents. In analyzer-based imaging, it is possible to detect the scattering properties of the sample by shifting the analyzer crystal to selected positions of its reflectivity curve. In particular, when the sample consists of a large number of micro-particles an overall effect can be observed. Phantoms containing contrast agents based on microbubbles were imaged at different angular positions of the analyzer crystal. High visibility of the details was demonstrated, and a strong contrast enhancement was measured compared to normal x-ray absorption techniques.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20182004     DOI: 10.1088/0031-9155/55/6/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

Review 1.  Potential for imaging engineered tissues with X-ray phase contrast.

Authors:  Alyssa Appel; Mark A Anastasio; Eric M Brey
Journal:  Tissue Eng Part B Rev       Date:  2011-08-02       Impact factor: 6.389

2.  Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study.

Authors:  Di Wu; Molly Donovan Wong; Yuhua Li; Laurie Fajardo; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2017-11-21       Impact factor: 3.609

3.  Using Microbubble as Contrast Agent for High-Energy X-Ray In-line Phase Contrast Imaging: Demonstration and Comparison Study.

Authors:  Di Wu; Molly Donovan Wong; Kai Yang; Aimin Yan; Yuhua Li; Laurie Fajardo; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  IEEE Trans Biomed Eng       Date:  2017-08-21       Impact factor: 4.538

4.  Molecular evaluation of thrombosis using X-ray phase contrast imaging with microbubbles targeted to P-selectin in mice.

Authors:  Rongbiao Tang; Wei-Min Chai; Fuhua Yan; Guo-Yuan Yang; Ke-Min Chen
Journal:  Eur Radiol       Date:  2015-12-02       Impact factor: 5.315

5.  Talbot phase-contrast x-ray imaging for the small joints of the hand.

Authors:  Dan Stutman; Thomas J Beck; John A Carrino; Clifton O Bingham
Journal:  Phys Med Biol       Date:  2011-08-12       Impact factor: 3.609

6.  Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

Authors:  Astrid Velroyen; Martin Bech; Arne Tapfer; Andre Yaroshenko; Mark Müller; Philipp Paprottka; Michael Ingrisch; Clemens C Cyran; Sigrid D Auweter; Konstantin Nikolaou; Maximilian F Reiser; Franz Pfeiffer
Journal:  PLoS One       Date:  2015-07-02       Impact factor: 3.240

7.  A Gaussian extension for Diffraction Enhanced Imaging.

Authors:  Fulvia Arfelli; Alberto Astolfo; Luigi Rigon; Ralf Hendrik Menk
Journal:  Sci Rep       Date:  2018-01-10       Impact factor: 4.379

Review 8.  Edge-illumination x-ray phase-contrast imaging.

Authors:  Alessandro Olivo
Journal:  J Phys Condens Matter       Date:  2021-07-13       Impact factor: 2.333

9.  Evaluation of microbubble contrast agents for dynamic imaging with x-ray phase contrast.

Authors:  T P Millard; M Endrizzi; N Everdell; L Rigon; F Arfelli; R H Menk; E Stride; A Olivo
Journal:  Sci Rep       Date:  2015-07-29       Impact factor: 4.379

10.  In-line phase contrast imaging of hepatic portal vein embolization with radiolucent embolic agents in mice: a preliminary study.

Authors:  Rongbiao Tang; Wei Huang; Fuhua Yan; Yong Lu; Wei-Min Chai; Guo-Yuan Yang; Ke-Min Chen
Journal:  PLoS One       Date:  2013-12-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.